Page 71

4 Read Cycle Contents Read Cycle by ESP ...................................................................................................................... 4-2 Read Cycle Serial Commands ..................................................................................................... 4-2 Multisymbol................................................................................................................................... 4-3 Trigger .......................................................................................................................................... 4-5 External Trigger State................................................................................................................. 4-11 Serial Trigger .............................................................................................................................. 4-12 Start Character (Non-Delimited) ................................................................................................. 4-13 Stop Character (Non-Delimited) ................................................................................................. 4-13 End of Read Cycle...................................................................................................................... 4-14 Good Decode Reads .................................................................................................................. 4-17 Gain Settings .............................................................................................................................. 4-18 Focus.......................................................................................................................................... 4-19 Scan Speed ................................................................................................................................ 4-20 Automatic Gain Control (AGC) Settings ..................................................................................... 4-21 Maximum Element...................................................................................................................... 4-22 Tracking Adjustment................................................................................................................... 4-23

After you’ve established communications and completed basic read rate testing, you will need to address the spatial and timing parameters associated with your application. In a typical operation, a bar-coded item moves along a line past a scanner. A trigger or timer activates a read cycle during which the scanner actively searches for symbols. You will need to decide how to initiate the read cycle and how and when to end it. Note: When assigning characters in user-defined fields, the characters NUL, <, >, and , can only be entered through embedded menus, not through ESP or serial commands. Note: You can learn the current setting of any parameter by inserting a question mark after the number, as in <K100?>. To see all K commands, send <K?>. Note on Serial Commands: To preserve continuity with other Microscan products, some serial configuration commands may include 0s or 1s as placeholders. In order for a these commands to be implemented, the parameter values or a comma must be included.

MS-890 Industrial Automation Scanner User’s Manual

4-1

Page 72

Read Cycle by ESP

Read Cycle by ESP

Click this button to bring up the Read Cycle menu.

To change a setting, double-click the setting and use your cursor to scroll through the options.

To open nested options, single-click the +.

Read Cycle Serial Commands Command Title Trigger Serial Trigger Character External Trigger State End of Read Cycle Good Decode Reads Multisymbol Start Serial Trigger Character End Serial Trigger Character Scan Speed Maximum Element Gain Settings AGC Settings Focus Tracking Adjustment

4-2

Command Format <K200,trigger mode,trigger filter duration> <K201,trigger character> <K202,external trigger state> <K220,end of read cycle mode,read cycle timeout> <K221,number before output,mode> <K222,number of symbols,multisymbol separator> <K229,start trigger character> <K230,end trigger character> <K500,scan speed> <K502,maximum element> <K504,gain adjustment,AGC mode> <K505,symbol detect status,minimum number of transitions> <K508,focus position> <K520,tracking adjustment>

MS-890 Industrial Automation Scanner User’s Manual

Page 73

Read Cycle

Multisymbol Usage:

Multisymbol is commonly used in shipping applications where a shipping symbol contains individual symbols for part number, quantity, etc. This feature allows one trigger to pick up all the symbols. AIAG and EAN-128 are two application standards that address this need.

Definition:

Multisymbol allows the user to define up to 12 symbols that can be read in a single read cycle.

Conditions: The following conditions apply: 1. Each symbol must be different to be read unless they appear in the scan line at the same time. 2. The maximum number of characters in a read cycle is 32520 for all symbols. 3. The maximum number of characters the scanner can transmit is calculated by: Preamble + maximum number of symbols * (aux id + symbology id + maximum symbol length + quality output + ((number of insertion cells x cell length)+ separator) + postamble + LRC = 37425. 4. All No Read messages are posted at the end of the data string. 5. If more than one symbol is within the scan beam at the same time, symbol data may not be displayed in the order of appearance. 6. If Matchcode Type is set to Sequential or if Trigger is set to Continuous Read 1 Output, Number of Symbols will default to 1 (if set to any number greater than 1).

Number of Symbols Definition:

Number of Symbols is the number of different symbols that can be read in a single read cycle.

Conditions: The following conditions apply: 1. When Number of Symbols is set to Single, the read cycle ends when one symbol is decoded and output. 2. When Number of Symbols is set to Multiple, all decoded symbol data (for both the same and different symbols) are output while the read cycle is active and/or no timeout has occurred. Serial Cmd: <K222,number of symbols,multisymbol separator> Default:

1

Options

1 to 12

MS-890 Industrial Automation Scanner User’s Manual

4-3

Page 74

Multisymbol

Multisymbol Separator Usage:

Used to delimit or separate data fields with a user defined character.

Definition:

The character that’s inserted between each symbol scanned when Multisymbol is set to any number greater than 1.

ESP:

To select a new multisymbol separator, double-click on Separator and select a character in the popup window.

Serial Cmd: <K222,number of symbols,multisymbol separator> Note: If Multisymbol Separator has been changed to any character other than the default comma and you wish to re-define the separator as a comma, use ESP or the embedded menu. Default:

, (comma)

Options:

Any available ASCII character, except NUL, <, >, and , .

4-4

MS-890 Industrial Automation Scanner User’s Manual

Page 75

Read Cycle

Trigger Trigger Mode Note: When doing calibration or read rate testing, the current trigger setting will be disregarded. Note: This command does not need to be followed by an <A> command. Definition:

The type of trigger event that will initiate the read cycle.

Serial Cmd:

<K200,trigger mode,trigger filter duration>

Default:

Continuous Read

Options:

0 = Continuous Read 1 = Continuous Read 1 Output 2 = External Level 3 = External Edge 4 = Serial Data 5 = Serial Data and External Edge

Continuous Read Usage:

Continuous Read is useful in testing symbol readability or scanner functions. It is not recommended for normal operations.

Definition:

In Continuous Read, trigger input options are disabled, the scanner is always in the read cycle, and it will attempt to decode and output every scan crossing a symbol. When To Output and No Read options have no effect on Continuous Read.

Serial Cmd: <K200,0>

MS-890 Industrial Automation Scanner User’s Manual

4-5

Page 76

Trigger

Continuous Read 1 Output Usage:

Continuous Read 1 Output can be useful in applications where it is not feasible to use a trigger and all succeeding symbols contain different information. It is also effective in applications where the objects are hand-presented.

Definition:

In Continuous Read 1 Output the scanner self-triggers whenever it decodes a new symbol or a timeout occurs. If End Of Read Cycle is set to Timeout and the symbol doesn't change, the scanner will repeat the output at the end of each timeout period. For example, if Timeout is set to one second, the scanner sends the symbol data immediately and repeats the output at intervals of one second for as long as the symbol continues to be scanned. If End Of Read Cycle is set to New Trigger, the scanner will send the current symbol data immediately, but send it only once. A new symbol appearing in the scanner’s range will be read and sent immediately provided it is not identical to the previous symbol read.

Serial Cmd: <K200,1> Caution: In automated environments, Continuous Read 1 Output is not recommended because there is no one to verify that a symbol was missed. Note: If Trigger is set to Continuous Read 1 Output, Number of Symbols will default back to 1 (if set to any number greater than 1).

4-6

MS-890 Industrial Automation Scanner User’s Manual

Page 77

Read Cycle

External Trigger Level Initiate Read Cycle: Object #1, moving in front of the detector beam, causes a change in the trigger state, which initiates the read cycle. End Read Cycle: The same object, moving out of the detector beam, causes another change in the trigger state, which ends the read cycle.

Usage:

This mode is effective in an application where the speeds of the conveying apparatus are variable and the time the scanner spends scanning each object is not predictable. It also allows the user to determine if a No Read has occurred.

Definition:

External Level allows the read cycle to begin when a trigger (change of state) from an external sensing device is received. The read cycle endures until the object moves out of the sensor range and the active trigger state changes again.

Serial Cmd: <K200,2> Important: Level and Edge apply to the active logic state (Open or Closed) that exists while the object is in a read cycle, between the rising edge and falling edge. Rising edge is the trigger signal associated with the appearance of an object. Falling edge is the trigger signal associated with the subsequent disappearance of the object. Note: In External Trigger Level, sending a non-delimited start serial character will start a read cycle and sending a non-delimited stop serial character will end it. See Start Character (Non-Delimited) and Stop Character (Non-Delimited) on page 4-13.

MS-890 Industrial Automation Scanner User’s Manual

4-7

Page 78

Trigger

External Trigger Edge Initiate Read Cycle: Object # 1, moving in front of the detector beam, causes a change in the trigger state, which initiates the read cycle. Initiate Second Read Cycle: Object # 2, moving in front of the detector beam, causes another change in the trigger state. This signal initiates a new read cycle and ends the previous read cycle unless Timeout is enabled and a good read or timeout has not occured.

Usage:

This mode is highly recommended in any application where conveying speed is constant or if spacing, object size, or timeouts are consistent.

Definition:

External Trigger Edge, as with Level, allows the read cycle to begin when a trigger (change of state) from an external sensing device is received. However, the passing of an object out of sensor range does not end the read cycle. The read cycle ends with a good read output or, depending on End of Read Cycle setting, a timeout or new trigger occurs.External Trigger Edge, as with Level, allows the read cycle to begin when a trigger (change of state) from an external sensing device is received. However, the passing of an object out of sensor range does not end the read cycle. The read cycle ends with a good read or with a No Read when a No Decode Timeout occurs.

Serial Cmd: <K200,3> Important: Level and Edge apply to the active logic state (Open or Closed) that exists while the object is in a read cycle, between the rising edge and falling edge. Rising edge is the trigger signal associated with the appearance of an object. Falling edge is the trigger signal associated with the subsequent disappearance of the object. Note: In External Trigger Level, sending a non-delimited start serial character will start a read cycle and sending a non-delimited stop serial character will end it. See Start Character (Non-Delimited) and Stop Character (Non-Delimited) on page 4-13.

4-8

MS-890 Industrial Automation Scanner User’s Manual

Page 79

Read Cycle

Serial Data Usage:

Serial Data is effective in a highly controlled environment where the host knows precisely when the object is in the scan zone. It is also useful in determining if a No Read has occurred.

Definition:

In Serial Data, the scanner accepts an ASCII character from the host or controlling device as a trigger to start a read cycle. A Serial Data trigger behaves the same as an External Edge trigger.

Serial Cmd: <K200,4>

Serial Data and External Edge Usage:

Serial Data and External Edge is seldom used but can be useful in an application that primarily uses an external sensing device but occasionally needs to be manually triggered. An auxiliary terminal can be connected to the Aux Port so the user can send the serial trigger character through the scanner to the host.

Definition:

In this mode the scanner accepts either a serial ASCII character or an external trigger pulse to start the read cycle.

Serial Cmd: <K200,5>

MS-890 Industrial Automation Scanner User’s Manual

4-9

Page 80

Trigger

Trigger Filter Duration Usage:

Trigger Filter Duration is useful where trigger bounce could cause false triggers.

Definition:

Trigger Filter Duration can prevent trigger bounce from falsely triggering the scanner by limiting the time in which trigger pulses can be received.

Serial Cmd: <K200,trigger mode,trigger filter duration> Default:

320 (10 ms)

Options:

0 to 65535 (0 to 2.047s in 31.25µs steps)

4-10

MS-890 Industrial Automation Scanner User’s Manual