Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 31 of 31

MS-890 Industrial Automation Scanner User's Manual, pages 301 to 308

Pages 301 to 308 of 308

The original document is the PDF (3.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan MS-890

Page 301

Appendices

Select Sequence Unlike poll requests, select commands always originate from the host and consist of serial configuration or operation commands to devices that are configured in Multidrop. The scanner complies with the command when it is polled during the cycle. End of Sequence

Start of Sequence

Concentrator RES 1F REQ Scanner 02

STX <T>ETX LRC 1F ACK

RES 1F ACK

Polling Sequence A RES (reset) is the first command in the select sequence. The 1F hex is the select address associated with Scanner 02 address. It is followed by a REQ (request). The scanner responds with its own select address, 1F hex, and an ACK (acknowledge). The concentrator then transmits an STX (start of text), the data (in this case a <T>), an ETX (end of text), and an LRC character. The scanner replies by transmitting its own address, followed by an ACK, acknowledging receipt of the command. Upon receipt of an ACK, the concentrator concludes the successful exchange with a RES. In the example above, the scanner only acknowledges a trigger counter request from the concentrator. It does not respond to the trigger counter request until a subsequent poll. For example, if the scanner’s trigger count was 12 at the time the trigger counter request was received, on a subsequent poll it would send 02T/00012. (The 02 at the beginning of the string is the scanner’s address.)

Select Reset If the scanner receives bad data from the concentrator, it transmits a SEL (its select address) and a NAK to the concentrator. The concentrator re-transmits the data up to three times. The concentrator will end the sequence with a RES (reset) if no ACK is received.

MS-890 Industrial Automation Scanner User’s Manual

A-37

Page 302

Multidrop Communications

Multidrop Addresses Multidrop Address 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

A-38

Poll Character ASCII HEX ^\ 1C ^^ 1E SP 20 " 22 $ 24 & 26 ( 28 * 2A , 2C . 2E 0 30 2 32 4 34 6 36 8 38 : 3A < 3C > 3E @ 40 B 42 D 44 F 46 H 48 J 4A L 4C

Select Character ASCII HEX ^] 1D ^1F ! 21 # 23 % 25 ' 27 ) 29 + 2B 2D / 2F 1 31 3 33 5 35 7 37 9 39 ; 3B = 3D ? 3F A 41 C 43 E 45 G 47 I 49 K 4B M 4D

Multidrop Address 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50

Poll Character ASCII HEX N 4E P 50 R 52 T 54 V 56 X 58 Z 5A \ 5C ^ 5E ` 60 b 62 d 64 f 66 h 68 j 6A l 6C n 6E p 70 r 72 t 74 v 76 x 78 z 7A | 7C ~ 7E

Select Character ASCII HEX O 4F Q 51 S 53 U 55 W 57 Y 59 [ 5B ] 5D _ 5F a 61 c 63 e 65 g 67 i 69 k 6B m 6D o 6F q 71 s 73 u 75 w 77 y 79 { 7B } 7D D 7F

MS-890 Industrial Automation Scanner User’s Manual

Page 303

Appendices

Appendix O, Glossary of Terms Active Closed, An optoisolated input-output that’s logically “on” when current flows through the connection points. Active Open, An optoisolated input-output that’s logically “on” when no current flows through the connection points. Analog Gain Adjustment (AGC), Adjustment to signal strength that seeks to maintain a constant level regardless of the range of the symbol. Application Record, A variation of EAN-128 which adds an application identifier to symbol data, including user-definable separators, brackets, and padding. Autocalibration, A routine that cycles through various optical settings and selects the combination that produce the best read rate. Autodiscrimination, The ability to decode several different symbologies without changing configuration. Auto Range, Outward focus of the scanner until an object is sensed by signal strength. The scanner then begins searching for a decodable symbol. Auxiliary Port, Auxiliary terminal connection for remote viewing and command inputs. Bar Code, A symbol in which data has been encoded in an array of parallel bars and spaces of varying widths. Baud Rate, The number of discrete signal events per second. Bits per second. Channel, A high-speed pathway between the computer and the control units of the peripheral devices. Check Digit, A Modulus 43 or Modulus 10 digit that is added to the symbol data for additional data integrity. Command Processing, Allows the user to enter ESP from the Aux Port or send serial string commands from the Aux Port. Configuration, A setup or process of changing a scanner’s settings to conform to a specific application. Concentrator, Intermediary device that relays data from scanners to a host and commands from the host to the scanner or other devices. Connector, Physical device (plug or socket) on a device or cable to provide in/out connectivity for various circuits and pins. Counter, Memory space provided to keep track of scanner events. Daisy Chain, Linkage of scanners to allow data to be relayed up to the host via Aux Port connections. Decode, A Good Read. The successful scanning and decoding of the information encoded in a symbol. Default, Restores ROM settings and resets the scanner. Delimited, A command or field that is bracketed by pre-defined characters. Decode Rate, The number of good reads per second decoded by the scanner. MS-890 Industrial Automation Scanner User’s Manual

A-39

Page 304

Glossary of Terms Depth of Field, The distance between the minimum and maximum range in which a scanner can read symbol. Discrete I/O, Inputs and outputs characterized by discrete signal transitions. EPROM, Erasable, programmable, read-only memory. Embedded Memory, Onboard memory device such as EPROM or flash. End of Read Cycle, The time or condition at which the scanner stops expecting symbol data to decode. External Edge, Allows a read cycle to be initiated by a trigger signal from an object detector when it detects the appearance of an object (rising edge). The read cycle ends with a good read, a timeout, or a new trigger. External Level, Allows a read cycle to be initiated by a trigger signal from an object detector. The read cycle ends when the object moves out of the detector’s range. Fixed Symbol Length, Increases data integrity by ensuring that only one symbol length will be accepted. Flash Memory, Memory that can be changed by downloading new code. Focal Length, The distance measured from the scanner to the center of the depth of field, or focal point. Focus, The point at which the tip of the scan beam is at its narrowest. Full Duplex, Auxiliary port data is sent directly to the host but not displayed on the auxiliary port screen. Gain, Optimal signal strength. Good Read, A decode. The successful scanning and decoding of the information encoded in a symbol. Half Duplex, Auxiliary port data is sent directly to the host and displayed on the auxiliary port screen. Intercharacter Delay, The time interval in milliseconds between individual characters transmitted from the scanner to the host. Intercharacter Gap, The extra space between the last element of one character and the first element of the adjacent character of a specific symbol. Ladder Orientation, An orientation in which a symbol’s bars are parallel to its direction of travel. Large Intercharacter Gap, Allows the scanner to read symbols with gaps between characters that exceed three times (3x) the narrow element width. Laser Framing, Setting scan width size by adjusting the on/off duration of the laser beam. Laser On/Off, When enabled, the laser is ON only during the read cycle, provided the scanner is enabled for a Serial or External trigger. LED, Light emitting diode. Longitudinal Redundancy Check (LRC), An error-checking routine that verifies the accuracy of transmissions. A-40

MS-890 Industrial Automation Scanner User’s Manual

Page 305

Appendices Matchcode, The ability to compare symbols being scanned against a master symbol that is stored in the memory of the scanner. Embedded Menu, Configuration options embedded in the scanner’s erasable memory. Mil, One thousandths of an inch or 0.0254 mm. In bar coding, a measurement standard that measures a symbol by the width of its narrowest element. Mismatch, An event that occurs when the scanned symbol does not match the master symbol that is stored in the memory of the scanner. Multisymbol, A scanner mode which allows a scanner to read more than one symbol in a single read cycle. Multidrop, A communications protocol for networking two or more scanners or other devices with a concentrator (or controller) and characterized by the use of individual device addresses and the RS-485 standard. Narrow Bar Width, The width of the narrowest bar of a given symbol, expressed in thousands of an inch (or mils). Narrow Margins, Allows the scanner to read symbols with quiet zones less than 8 times the width of the narrow bar element. Non-Delimited, A command that is not bracketed by pre-defined characters. Non-Volatile RAM (NOVRAM), Random Access Memory that is available on power on; that is, after power to the unit has been recycled. No Read, A failed decode attempt. A condition that occurs when the scanner is set up to decode symbols but no symbol is scanned during the read cycle. NOVRAM, Non-volatile random access memory. Data that is saved for “power on” is saved to NOVRAM. Number of Decodes, The number of times a symbol is scanned by the scanner during one pass through the laser beam. Object Detector, A photoelectric device used to sense the presence or absence of an object (also referred to as a package detector). Output, To transfer or transmit from the computer to a peripheral device or communications line. A channel or communications line. Decoded data or discrete signal. Output Format, The modification of data output according to a user-defined index of Extraction and Insertion commands. Parity, An error detection routine in which one data bit in each character is set to 1 or 0 so that the total number of 1 bits in the data field is even or odd. Picket Fence Orientation, An orientation in which a symbol’s bars are perpendicular to its direction of travel. Pitch, Symbol (or scanner) rotation around the center of a line perpendicular to the symbol’s bars. Point-to-Point, A protocol consisting of a single communications event, typically used to connect a scanner to a terminal or host computer. Port, Logical circuit for data entry and exit. (One or more ports may be included within a single connector.) MS-890 Industrial Automation Scanner User’s Manual

A-41

Page 306

Glossary of Terms Protocol, The rules for communication between devices, providing a means to control the orderly flow of information between linked devices. Quiet Zone, Specified “clear” (nonprinted) area immediately before and after the symbol. The area is usually white (for black and white symbols) and at least 10 times the width of the narrowest bar, as measured in thousands of an inch. The quiet zone can be a shade or color other than white as long as its density remains consistent and it has the required contrast relative to the bars. RAM (Random Access Memory), Memory that is lost after power is recycled to the unit. Raster, Multiple stacked scans produced by a separate oscillating mirror or by a spinning mirror with varying facet angles. Read Cycle, A programmed period of time or condition during which the scanner will accept symbol input. Read Range, The distance within which a symbol can be read reliably, as measured from the front of the scanner. Relay, An electrical switch that allows a low power to control a higher one. Reset, Clears current data and initializes counters and configuration parameters. ROM (Read-Only Memory), Memory that cannot be changed. Scanner, A scanning device that is comprised of a scan head and a decoder integrated in one package. Scan Rate (SR), The number of decodes per second that a given scanner is capable of casting. Scan Width (SW), The width across the scan beam at a given distance from the scanner in which a symbol can be read. Separator, A character that separates data fields. Serial Commands, Online data strings such as <D> or <P> sent from a host or auxiliary terminal to a scanner or other device. Serial Configuration (Host Configuration), Serial command specifically for changing configuration and distinguished from operational command by the fact that they modify the non-volatile for power up configuration. Skew, Symbol (or scanner) rotation around the center of the skew axis. Specular Reflection Zone, The narrow zone straight out from the scanner in which direct reflected light from a symbol can distort the scanner’s ability to distinguish bars from spaces. Supplemental, A character or data string that is appended to the main symbol. Sweep, One pass of the raster, up or down. Sweep Rate (SwR), The number of passes per second, up or down, describing the raster image. Symbol Density, The number of characters per inch (or other unit of measure) encoded in a symbol. Symbol Height, Regardless of orientation, the measurement taken along the length of a symbol’s individual bars. A-42

MS-890 Industrial Automation Scanner User’s Manual

Page 307

Appendices Symbol Length, Regardless of orientation, the measurement taken across the symbol’s bars from one end to the other, including the quiet zone. Symbology, A set of symbols, such as Code 39 or Code 128, that have special rules to define the widths and positions of bars and spaces to represent specific numeric or alphanumeric information. Symbology ID, An AIM standard prefix character that identifies the symbol type. Symbol Speed, The distance per second that a symbol moves as it travels through the scan lines. Symbol Transitions, The transition of bars and spaces on a symbol, used to detect the presence of a symbol on an object. Tilt, Symbol (or scanner) rotation around the center line of the scan beam. Timeout, A user-selected period of time that ends a scanner's read cycle. Tracking, Adjustment of the precision of analog-to-digital conversion. Transparent, Data is passed between the auxiliary port and the host with keyed data echoed to the auxiliary port Trigger, A signal, transition, or character string that initiates a read cycle. TTY, Abbreviation for TeleTYpewriter. This is a device that sends information character by character over an analog line. Watchdog Timer, A security device that detects system crashes and attempts to reset the scanner. Watchdog Reset, A reset that is forced whenever the software locks up. Wildcard, User-defined character entered into a master symbol to permit matches with variable characters.

MS-890 Industrial Automation Scanner User’s Manual

A-43

Page 308

Glossary of Terms

A-44

MS-890 Industrial Automation Scanner User’s Manual