MS-890 Industrial Automation Scanner User's Manual, pages 281 to 290

Pages 281 to 290 of 308

The original document is the PDF (3.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan MS-890

Page 281

Appendices

Appendix E, Embedded Menus In addition to ESP, you can also use a communications menu such as HyperTerminal to establish communication with Microscan’s embedded menus.1 12. With your host connected to the 9-pin configuration port, set your host communications settings as follows: 57.6K baud, 8 Data Bits, 1 Stop Bits, and None Parity. OR, with your host connected to the 25-pin configuration port, set your host communications settings as follows: 9600, 7, 1, and Even. 13. Set Flow Control to None. 14. Make the communications port selection. (Usually COM 1 or COM 2 for desktops and COM 1 for laptops.) 15. Upon connection, send a <D> command to bring up the main menu.

Note: The 9-pin configuration port settings are fixed. Important: To receive symbol data through the 9-pin configuration port, you must enable the port with the following command: <K146,,1>. 16. Press the return key (CR) to view the communications menu. Menu navigation commands are case sensitive. Use the space bar or N to advance to the next item, CR (return key) to select a highlighted item, B to return to the previous item, M to return to the previous menu, and ESC to return to the Main menu or to exit the program. When exiting the program, you will be prompted to save your active settings for power up (Y or N). Typing Y will be equivalent to saving with a <Z> command.

1. If you are using HyperTerminal, you may find that the initial screen is unviewable when you call up the program with the <D> command. If this occurs, simply exit the embedded menu with a ESC, E, and N sequence and repeat the <D> command.

MS-890 Industrial Automation Scanner User’s Manual

A-17

Page 282

Defaulting/Saving/Initializing

Appendix F, Defaulting/Saving/Initializing Active Memory is where the scanner’s settings are stored during current use and are initialized by an <A> command. Microscan Defaults are where the scanner’s default application/boot programs are stored. They can only be changed by changing the application/boot codes.1 User-Saved Settings are where user-defined settings are saved for power-on.

Defaulting Defaulting occurs when default settings (either Microscan or user-saved) are restored. Defaulting might be necessary if you have to make temporary changes, communications between the scanner and another device are lost or interrupted, or you are using incompatible equipment (for example, a terminal that is set at 9600 baud communicating with a scanner that is set at 38.4K baud).

Restore User-Saved Settings to Active Memory • Restores user-defined settings to active memory. • Initializes serial configuration commands in active memory and resets counters to zero.

Restore User-Saved Settings to Active Memory by Serial Command Send <An> command to the scanner. Note: There is no equivalent ESP command.

Restore Microscan Defaults to Active Memory • Restores Microscan defaults to active memory. • Initializes serial configuration commands in active memory and resets counters to zero. • Does not save settings for power-on.

Restore Microscan Defaults to Active Memory by Serial Command Send <Ard> command to the scanner.

Restore Microscan Defaults to Active Memory by ESP Right-click in the configuration window and select Default All ESP Settings.

1. See your Microscan sales representative to access the latest application code.

A-18

MS-890 Industrial Automation Scanner User’s Manual

Page 283

Appendices

Restore Microscan Defaults to Active Memory and Power-On Caution: Defaulting the scanner to Microscan default settings will overwrite user-saved settings. • Restores Microscan defaults to memory. • Restores Microscan defaults to user-saved settings for power-on. • Initializes serial configuration commands in active memory and resets counters to zero.

Restore Microscan Defaults to Active Memory and Power-On Send <Zd> command to the scanner.

Restore Microscan Defaults to Active Memory and Power-On by ESP 1. Right-click in the configuration window and select Default All ESP Settings. 2. Right-click and select Save to Reader and Send and Save.

Restore Microscan Defaults by Hardware Default There is no hardware default for the MS-890. Default commands can be entered from any of the host connectors. Since the default communications settings on the 9-pin connector are fixed, you can always send a default the scanner through this port with a software command.

MS-890 Industrial Automation Scanner User’s Manual

A-19

Page 284

Defaulting/Saving/Initializing

Saving Power-On settings are those that are saved by a <Z> command and are loaded into active memory whenever power to the scanner is recycled.

Save Active Settings (Except Factory) for Power-On Initializes serial configuration commands into active memory and resets counters to zero. Saves all current settings except factory settings to user-saved settings for power-on.

Save Active Settings (Except Factory) for Power-On by Serial Command Send <Z> command to the scanner.

Save Active Settings (Except Factory) for Power-On by ESP Right-click in the configuration window and select Save to Reader, then Send and Save.

Initializing Initializing occurs whenever any command or set of commands is implemented. Initializing is a part of all save and default functions. It is also used as a follow-on to implement serial configuration commands. • Initializes serial configuration commands into active memory and resets counters to zero. • Does not save settings for power-on.

Initializing by Serial Command Send <A> after a serial configuration command or a string of serial configuration commands. For example: <K141,1><A>.

Initializing by ESP Right-click in the configuration window and select Save to Reader, Send No Save. This will initialize all serial configuration changes that have been made in the current ESP session. Note: Allow a 1.5 second delay after sending the <A> command before resuming communications.

Loss of Communications Making changes to communications with the host such as Baud Rate, Parity, Stop Bits, LRC, etc. without corresponding changes in linked device(s) can result in the loss of menu access through the 25-pin port and wiring box connections. If this should occur, connect the scanner to the 9-pin port and set your host communications settings as follows: 57.6K baud, 8 Data Bits, 1 Stop Bits, and None Parity. These settings for this port are fixed and cannot be changed.you should restore the scanner’s defaults.If you wish to return to the 25-pin host port, you’ll first need to change the scanner’s communications settings by sending: <K100,4,1,0,0><Z>.

A-20

MS-890 Industrial Automation Scanner User’s Manual

Page 285

Appendices

Appendix G, Position Scanner and Symbol In positioning the scanner in relation to the symbols being scanner, consider the following: • Position the scanner in a place devoid of sunlight, bright lights, or laser light from other sources. • Avoid excessive tilt, skew, or pitch. Maximum tilt is determined by symbol characteristics and the number of decodes required. Maximum skew is ±40°; maximum pitch is ±50°.1 • Pitch symbol (or scanner) slightly to avoid specular reflection, the return of direct, non-diffused light. Specular reflection is avoided by pitching symbols at least 5° plus or minus from a line perpendicular to the default position of the Raster Bottom and Raster Top.2 Note: Another way to avoid specular reflection is to skew the scanner slightly in relation to the symbol.

Scanner Position

1. Maximum tilt is determined by symbol characteristics and number of decodes required. 2. The specular reflection zone is a narrow zone straight out from the scanner in which direct reflected light from a symbol can distort the scanner’s ability to distinguish bars from spaces.

MS-890 Industrial Automation Scanner User’s Manual

A-21

Page 286

Object Detector

Appendix H, Object Detector In a typical operation, a scanner will wait for symbol data only during a triggered read cycle. A read cycle is initiated by a “trigger” and can be in the form of a serial command from the host (internal trigger) or a signal from an object detector (external trigger). When an object detector (also called a sensor, package detector, etc.) is used, it is set up so that its beam will bounce off the approaching object and the resulting pulse will be sent to the scanner to begin the read cycle. Typically, a detector is positioned so that it will detect the presence of an object before its symbol can be scanned. An object detector is mounted in almost any position relative to the object as long as: (1) the object passes within range of the detector and (2) direct or reflected light from the detector does not interfere with the scanner’s reception. As the item continues to move down the line, its symbol moves into the scanner beam and is read by the scanner. The drawing below shows a symbol in the picket fence direction with the object detector positioned so as not to cause interference.

Object Detector Operation

A-22

MS-890 Industrial Automation Scanner User’s Manual

Page 287

Appendices

Appendix I, Bar Code Configuration You can configure the MS-890 by presenting Code 128 symbols encoded with serial commands. Note: Your scanner does not need to be enabled for Code 128 in order to enter Bar Code Configuration.

Entering Bar Code Configuration The symbol used to enter configuration is the 7-character code 128 symbol shown below. It is not required that the scanner be configured to read code 128 symbols to read this start symbol or the following configuration symbols. To set up Bar Code Configuration: 1. Put the scanner in a read cycle mode. 2. Place a special Code 128 configuration Start symbol (provided below) in the scanner’s field of view.

If the scanner is able to read the Start symbol, it will begin to beep and the performance LEDs will activate. 3. When the scanner starts to beep, remove the configuration symbol from the scanner’s field of view. The scanner is now in Bar Code Configuration mode. During Bar Code Configuration mode, the LEDs will illuminate in a sequential pattern to indicate that the scanner is ready to be configured. You can create your own start symbol by encoding the following character sequence in a Code 128 symbol: FNC4 <_CFG>

MS-890 Industrial Automation Scanner User’s Manual

A-23

Page 288

Bar Code Configuration

Using Configuration Symbols Once in Bar Code Configuration mode, serial command data encoded in Code 128 symbols is decoded by the scanner as serial input. Configuration symbols must meet the following conditions: 1. The only valid symbology for Bar Code Configuration is Code 128. 2. Symbol data may contain more than one command, but individual symbols must be presented individually. This is because only the first symbol in a read cycle will be used as a possible configuration symbol. A symbol that is presented to the scanner must be read 25 times consecutively to be used as a valid symbol. Once this is done, the scanner will interpret the symbol data in the same fashion as it interprets serial data. 3. Any valid command may be encoded in Code 128 symbols, including operational commands. Because the data is treated like serial input, multiple symbols may be used to represent one command as long as the symbols are presented individually and in the correct order. 4. Read Rate commands may also be used to enter Read Rate from Bar Code Configuration mode. 5. When in Read Rate, the scanner will read the symbologies that were enabled prior to entering Bar Code Configuration mode. However, the scanner will read a <J> in Code 128 regardless of the current enable/disable state of Code 128. Once the <J> is issued, the scanner will exit both Read Rate and Bar Code Configuration mode. To exit Read Rate and remain in Bar Code Configuration mode, present the start symbol once again. Symbols decoded during Read Rate will not configure the scanner. Scan the symbol shown to the right to start a Read Rate test.

Exiting Bar Code Configuration There are multiple ways of exiting Bar Code Configuration. The first way is simply to decode a symbol encoded with the <J> command, or to enter a <J> command from a terminal. The scanner will beep when exiting Bar Code Configuration in response to a <J> command. Any command that executes a software reset will also end Bar Code Configuration mode. These commands include the Save family as well as the Reset family (<Z>, <Zc>, <Zrd>, <Zrc>, <A>, <Arc>, <Ard>). To end the Read Rate test and Bar Code Configuration mode, scan this symbol:

Configuration changes will remain in effect, as would changes made by using serial commands or ESP. A-24

MS-890 Industrial Automation Scanner User’s Manual

Page 289

Appendices

Appendix J, Test Read Rate Test Read Rate by Bar Code Configuration You can enter a Read Rate test by scanning the following symbols: Enable Bar Code Configuration (Also activates the scanner’s read performance LEDs.)

Enable All Symbologies

Start Read Rate Test

End Read Rate Test and Disable Bar Code Configuration

Test Read Rate by Serial Command (Static Symbol) 1. Position a stationary symbol in front of a functioning scanner at the scan distance used in your application. 2. Set for single scan line scanning (Raster Top setting equal to Raster Bottom). 3. Enter a <C> command to see the decodes per second. The decode rate is the number of decoded scans per total number of scan. It will appear at the beginning of the data strings. Note: You can also enter a <Cp> command to see the percentage of decodes per scans. 4. Make a note of the decode rate. You will need this when calculating the number of decodes (see Appendix K, Formulas for Number of Decodes on page A-27). 5. End the test by sending the <J> command.

MS-890 Industrial Automation Scanner User’s Manual

A-25

Page 290

Test Read Rate

Test Read Rate by ESP See Read Rate in Chapter 12, Utilities.

Test Read Rate with a Moving Symbol Before testing with a moving symbol, it is highly recommended that you calculate the expected number of decodes by using the formulas in Appendix K, Formulas for Number of Decodes on page A-27. Once you’ve mounted the scanner, established a good read rate with a stationary symbol, and calculated the number of decodes for your symbol speed, you can begin decoding with moving symbols.

Number of Decodes To ensure reliable scanning, you need to apply a minimum of five decodes to each symbol. This means that all variables, symbol speed, read range, etc. are significant. Note: Variations between symbols are common. For this reason, the greater the number of sample symbols tested, the more likely you are to achieve optimum decode rates. In general, the number of decodes of a given symbol can be increased by: • Increasing symbol height • Decreasing symbol length • Increasing scan rate (spinning mirror speed) • Slowing symbol speed • Decreasing raster sweep rate • Decreasing raster height

A-26