The text of a manual · part 31 of 32
MS-880 Industrial Long Range Scanner User's Manual, pages 301 to 310
Pages 301 to 310 of 312
The original document is the PDF (6.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-880
Page 301
Glossary of Terms Host. A computer, PLC, or other device that is used to execute commands and process data and discrete signals. Host Port. The pins or connections on a scanner or other device that physically connect with a host and - using the RS-232, RS-422, or RS-485 standards - pass data and serial commands from one device to another. Initialize. Implement serial configuration commands into the scanner’s active memory.
MS-880 Industrial Long Range Scanner User’s Manual
A-45
Appendices
Input. A channel or communications line. Decoded data or a discrete signal that is received by a device. See Output. Intercharacter Delay. The time interval in milliseconds between individual characters transmitted from the scanner to the host. Intercharacter Gap. The extra space between the last element of one character and the first element of the adjacent character of a specific bar code symbol. IrDA. Infrared Data Association which promotes interoperable, infrared data interconnection standards. Label Height. Regardless of orientation, the measurement taken along the length of a label’s individual bars. Label Length. Regardless of orientation, the measurement taken across the label's bars from one end to the other, including the quiet zone. Label Speed (LS) is the distance per second that a label moves as it travels through the scan lines. Label Transitions. The transition of bars and spaces on a label, used to detect the presence of a label on an object. Ladder Label Orientation. A bar code label in which the bars are parallel to the label’s direction of travel. Large Intercharacter Gap. Allows the scanner to read symbols with gaps between bar code characters that exceed three times (3x) the narrow element width. Laser Framing. Setting scan width size by adjusting the on/off duration of the laser beam. Laser On/Off. When enabled, the laser is ON only during the read cycle, provided the scanner is enabled for a Serial or External trigger. LED. Light emitting diode. Longitudinal Redundancy Check (LRC). An error-checking routine that verifies the accuracy of transmissions. Master Scanner. First scanner in a daisy chain mode and linked directly to the host and in tandem to slave scanners. Matchcode. The ability to compare bar code labels being scanned against a master label that is stored in the memory of the scanner. Embedded Menu. Configuration options embedded in the scanner’s erasable memory. ESP-MP Menu. Easy Setup Program - Multiple Platform. Configuration program that runs in Windows-based operating systems 95 and above.
Page 302
Appendix Q
Appendices
Mil. One thousandths of an inch or 0.0254 mm. In bar-coding, a measurement standard that identifies a bar code label by the width of its narrowest element. Mismatch. An event that occurs when the scanned bar code label does not match the master label that is stored in the memory of the scanner. Multilabel. A scanner mode which allows a scanner to read more than one bar code label in a single read cycle. Multidrop. A communications protocol for networking two or more scanners or other devices with a concentrator (or controller) and characterized by the use of individual device addresses and the RS-485 standard. Narrow-bar-width. The width of the narrowest bar of a given label, expressed in thousands of an inch (or mils). Narrow Margins. Allows the scanner to read symbols with quiet zones less than 8 times the width of the narrow bar element. Non-delimited. A command that is not bracketed by pre-defined characters. Non-volatile RAM (NOVRAM). Random Access Memory that is available on poweron; that is, after power to the unit has been recycled. Noread. A non-read. A condition that occurs when the scanner is set up to decode labels but no label is scanned during the read cycle. Normally Closed. A discrete output state that is only active when open. Normally Open. A discrete output state that is only active when closed. NOVRAM. Non-volatile random access memory. Data that is saved for “power-on” is saved to NOVRAM. Number of Decodes. The number of times a bar code label is scanned by the scanner during one pass through the laser beam. Object Detector. A photo electric device used to sense the presence or absence of an object (also referred to as a package detector). Output. A channel or communications line. Data or discrete signals that are transmitted or displayed by a device. Output Format. The modification of data output according to a user-defined index of Extraction and Insertion commands. Parity. An error detection routine in which one data bit in each character is set to 1 or 0 (zero) so that the total number of 1 bits in the data field is even or odd. Picket Fence Label Orientation. A bar code label in which the bars are perpendicular to the label’s direction of travel. Pitch. Label (or scanner) rotation around the center of a line perpendicular to the label’s bars. Point-to-Point. A protocol consisting of a single communications event, typically used to connect a bar code scanner to a terminal or host computer. Port. Logical circuit for data entry and exit. (One or more ports may be included within a single connector.)
A-46
MS-880 Industrial Long Range Scanner User’s Manual
Page 303
Glossary of Terms Protocol. The rules for communication between devices, providing a means to control the orderly flow of information between linked devices. Quiet Zones. Specified “clear” (non printed) areas immediately before and after the bar code symbol. The area is usually white (for black and white bar code) and at least 10 times the width of the narrowest bar, as measured in thousands of an inch. The zones can be other than white as long as their densities remain consistent and they have the required contrast relative to the bars. RAM. (Random Access Memory) Memory that is lost after power is recycled to the unit. Raster. Multiple, stacked scans produced by a separate oscillating mirror or by a spinning mirror with varying facet angles. Read Cycle. A programmed period of time or condition during which the scanner will accept bar code label input. Read Range. The distances in which a label can be reliably read, as measured from the front of the scanner. See “Depth of Field.” Relay. An electrical switch that allows a low power to control a higher one. Reset. Sets all counters to zero.
Scanner. A scanning device that is comprised of a scan head and a decoder integrated in one package. Scan Rate (SR) The number of decodes per second that a given scanner is capable of casting. Scan Width (SW) is the width across the scan beam at a given distance from the scanner in which a label can be read. Send. Transmit data from one device to another. Separator. A character that separates data fields. Serial Commands. Online data strings such as <D> or <P> sent from a host or auxiliary terminal to a scanner or other device. Serial Configuration (Host Configuration). Serial command specifically for changing configuration and distinguished from operational command by the fact that they modify the non-volatile for power up configuration. Skew. Label (or scanner) rotation around the center of the skew axis. Slave Scanner. Linked to the master or preceding scanner in a daisy chain and relays bar code data to the host. See “Daisy Chain.” Specular Reflection Zone. The narrow zone straight out from the scanner in which direct reflected light from a label can distort the scanner’s ability to distinguish bars from spaces. Supplemental. A character or data string that is appended to the main bar code symbol. MS-880 Industrial Long Range Scanner User’s Manual
A-47
Appendices
Rising Edge. A change of state (to active) that initiates (and in some cases ends) a read cycle with a new trigger, an edge trigger, or the leading edge of a level trigger. (See Falling Edge.) ROM. (Read Only Memory) Memory that cannot be changed.
Page 304
Appendix Q Sweep. One pass of the raster, up or down. Sweep Rate (SwR) is the number of passes per second, up or down, describing the raster image. Symbol. A bar code. A decodable unit of information that is recognized by a bar code scanner. Symbology. A code type, such as Code 39 or Code 128, with special rules to define the widths and positions of bars and spaces to represent specific numeric or alphanumeric information. Symbology ID. An AIM standard prefix character that identifies the bar code type. Tilt. Label (or scanner) rotation around the centerline of the scan beam. Timeout. A user-selected period of time that ends a scanner's read cycle. Tracking. Adjustment of the precision of analog-to-digital conversion.
Appendices
Transmission. The transfer of data over a communications channel. Transmit. Send or convey signals or information from one device to another. Transparent. Data is passed between the auxiliary port and the host with keyed data echoed to the auxiliary port Trigger. A signal, transition, or character string that initiates a read cycle. Watchdog Timer. A security device that detects system crashes and attempts to reset the scanner. Watchdog Reset. A reset that is forced whenever the software locks up. Wild Card. User-defined character entered into a master label to permit matches with variable characters.
A-48
MS-880 Industrial Long Range Scanner User’s Manual
Page 305
Index Numerics
Auxiliary System Data 3-14
25-pin host connector Host connector 1-3 9-pin Host Configuration Connector 1-3
B
A
C Calibration Database by embedded menu 7-6 by ESP 7-3 by serial command 7-1, 7-4 Calibration Database, overview 7-2 Calibration with Multilabel 7-2, 8-6 Caution Summary i-xiv CDRH i-xii CE Compliance i-xii Check Digit Codabar 5-13 Code 39 5-8 I 2 of 5 5-14 Checksum 17-9 Codabar 5-11 Code 128 5-22 Code 39 5-8 Code 93 5-26 Code Length I 2 of 5 5-15 Code Type 17-13 Code Type, Output Filtering 13-12 Code Types by Embedded Menu 5-4
MS-880 Industrial Long Range Scanner User’s Manual
Index
About This Manual i-xi Active Data Base Settings 8-10 Active State 14-4 Active State, discrete outputs 14-6 Advanced Output Format by ESP 13-9 AGC 10-6 AGC Status 6-9 Ambient Temperature 15-11 Application code 17-5 Application Record UCC/EAN-128 5-23 Application Record Brackets, UCC/EAN-128 5-24 Application Record Padding, UCC/EAN-128 5-25 Application Record Separator UCC/EAN-128 5-24 Approvals i-xii As Soon As Possible, output 12-6 ASCII Table, including control characters A-21 Auto Connect 1-9 Auto Range 6-6 Autocalibration 1-13 by embedded menu 6-8, 6-10 by ESP 6-4 by serial command 6-7 Autocalibration Steps 6-3 Autoconfigure 2-16 Autodiscriminate, Code Types 5-29 Automatic/Static Mode 8-6 Aux Port Communications Parameters 2-14 Auxiliary Port 2-8
Background Color 5-7 Bar Code Symbologies A-3 Bar Widths, Pharma Code 5-28 Baud Rate aux port 2-14 host port 2-5 Beeper A-4 Beeper Status 12-10 Bottom Offset 9-4 BSMI i-xii
I-1
Page 306
Index
Index by embedded menu 5-3 by ESP 5-2 by serial command 5-3 COM1 1-8 Command Processing Mode 2-13 Communication Protocol Commands A-22 Communications 2-1 by embedded menu 2-4 by ESP 2-3 by serial command 2-3 host 25-pin 2-2 host 9-pin 2-2 host by wiring box 2-2 host IrDA port 2-2 Communications Options 2-2 Communications Port 1-8 Communications, loss of A-27 Communications, Specifications A-3 Configuration Status 3-14 Configuration System Data 3-14 Connect 1-9 Connector, power A-6 Connectors, Electrical A-6 Continuous Read 4-4 Continuous Read 1 Output 4-5 Control Characters A-20 Control Trigger 8-8 Control Trigger Mode, optoelectric database 8-7 Control/Hex Output 12-9 Counters 17-6 Counts 15-12 cUL i-xii
D Daisy Chain Autoconfigure 2-16 Daisy Chain ID 2-15 Daisy Chain Mode 2-12 Daisy Chain Remote Scanner ID 2-17 Daisy Chain Scanner ID 2-17 Daisy Chain Scanner Number 2-17 Data Bits aux port 2-14
I-2 host port 2-6 Database Index 7-4 DataHighway Plus 3-15 Decode Rate A-30, A-31 Decodes/Second Test 17-10 Decoding Direction, Pharma Code 5-28 Default Commands A-24 Default Flash Defaults to Active Memory and for Power-on A-25 Default NOVRAM Defaults to Active Memory A-24 Defaulting 17-13 Defaulting/Saving/Initializing A-24 delimited 4-10 Device Control 17-12 DeviceNet A-36 DFALT-C 15-7 DFALT-F 15-7 DH485 A-37 Diagnostic Outputs 14-11 Diagnostics 15-1 by embedded menu 15-3 by ESP 15-2 by serial command 15-2 Dimensions, MS-880 Scanner A-2 Disclaimer i-ii Discrete I/O by embedded menus 14-3 by ESP 14-2 by serial command 14-2 Download 17-5 Download code 17-5
E EAN Status 5-17 EAN-128 5-23 Easy Setup Program i-ix Easy Setup Program - Multiple Platform 1-6 Electrical Specifications A-6 Embedded Menu Mode A-14 Emissions, Specifications A-2 End of Read Cycle 4-13 End of Read Cycle, output 12-7
MS-880 Industrial Long Range Scanner User’s Manual
Page 307
End Read Rate Test 17-11 End Serial Trigger Character 4-11 Enter Master Label Data 11-12 Environmental, Specifications A-2 ESP (Easy Setup Program) i-ix Ethernet A-37 External Trigger Edge 4-7, 4-8 External Trigger Level 4-6 External Trigger State 4-12 Extraction by ESP 13-5 by Serial Command 13-6 Extraction Mode 13-5
F
G Gain 7-4, A-34 Gain Adjustment 10-6 General Specifications A-2
H Half Duplex Mode 2-10 Hardware Required 1-2 Hex Output 12-9 Hex String 13-8 High Temperature Threshold 15-8 Host 25-pin Connector A-8 Host 9-pin Configuration Connector A-7 Host Communications i-xi Host connector 1-3 Host Port Parameters 2-5
I Immunity A-2 Initializing 17-13 Initializing (resetting) Commands A-27 Input 1 14-4 Insertion by ESP 13-7 by Serial Command 13-8 Insertion Mode 13-7 Install ESP-MP 1-6 Intercharacter Delay 3-11 Interface A-3 Interface Standards A-36 Interleaved 2 of 5 5-14 IrDA Communications for Palm Pilot A-15 IrDA Configuration Port A-13 IrDA Port 1-3 IrDA Status A-13
Index
FCC i-xii File Transfer 17-5 Filter #, Output Filtering 13-12 Filtering 13-11 Fixed Bar Length Pharma Code 5-27 Fixed Code Length Codabar 5-12 Code 128 5-22 Code 39 5-9 Code 93 5-26 PDF417 5-20 Flash memory i-ix Focal Range 6-11 Focus 10-5 Focus Position 7-4, 10-5 Focus Positions 6-11 Focus Stepping 6-5 Formulas for Number of Decodes A-31 From Host 3-7 Full ASCII Set (Code 39) 5-10 Full Duplex Mode 2-11 Fully Optoisolated circuit A-9, A-11
Glossary of Terms A-43 Good Decode Reads 4-9 Good Read/Match Counter 17-6 Good Read/Match Counter Reset 17-7 Guard Bar (I 2/5) 5-16
K K Commands A-19 Keystrokes i-xi
L Label Density A-34
MS-880 Industrial Long Range Scanner User’s Manual
I-3
Page 308
Index
Index Label Dimensions A-34 Label Height A-31 Label Length A-32 Label Ratio A-34 Label Speed A-31, A-32, A-34 Ladder Calculation, single line A-31 Large Intercharacter Gap Codabar 5-12 Code 39 5-9 laser beam i-xiv Laser Control 9-6 Laser Framing 9-7, A-34 Laser High Warning 15-5 Laser Light, Specifications A-2 Laser Low Warning 15-6 Laser Off Time 9-8 Laser On Time 9-8 Laser On/Off 9-6 Laser Power 6-9, 9-8 Laser Scanning 17-12 Laser Scanning, disable 17-12 Laser Settings by embedded menu 9-9 Latch Mode, discrete outputs 14-7 Latch on Trigger, optoelectric database 8-10 Lifetime Hours 15-10 Load Current Settings from Configuration Database 7-5 Longitudinal Redundancy Check 3-9 Low Temperature Threshold 15-9 LRC 3-9
M Master Label by ESP 11-11 Master Label Data Delete 11-14 Enter 11-12 Request 11-13 Request All 11-13 Store Next Label Scanned 11-15 Master Label Database 11-11 Master Label Database Size 11-11
I-4
Master Scanner 2-16 Match Counter 17-6, 17-7 Match Length 11-7 Match Start Position 11-6 Match, discrete outputs 14-5 Matchcode by embedded menu 11-3 by ESP 11-2 by serial command 11-2 Matchcode Type 11-5 Matchcode, overview 11-4 Maximum Element 10-8 Mechanical A-2 Menu Mode 2-19 Minimum Number of Bars, Pharma Code 5-28 Mirror Type A-3 Mismatch Counter 17-7 Mismatch Counter Reset 17-7 Mismatch or Noread, discrete outputs 14-5 Mismatch, discrete outputs 14-5 Model Selection 1-7 Motor Off 17-12 Motor On 17-12 Mounting Plate, wiring box 16-9 Mounting Specifications A-4 Multidrop 3-6 Multidrop Addresses A-42 Multidrop Communications A-38 Multilabel 4-16 Multilabel Decode Rate Test 17-10 Multilabel Output Format Assignment 13-10 Multilabel Percent Test 17-10 Multilabel Separator 4-17
N Narrow Margins 5-5 Network Client 3-15 Network Trigger 4-8 New Master Pin 11-16 New Trigger 4-15 Noise Interference A-36 non-delimited 4-10 Noread Counter Reset 17-6
MS-880 Industrial Long Range Scanner User’s Manual
Page 309
Noread Message, output 12-4 Noread, discrete outputs 14-6 Not Optoisolated A-11 NOVRAM Corrupt Warning Status 15-7 NOVRAM/Default Warnings 15-4 Null Modem Cable 1-2 NULs, defining A-20 Number of Active Database Settings 8-10 Number of Decodes A-30 Number of Filters 13-14 Number of Labels 4-16 NVRAM-C 15-7 NVRAM-D 15-7
O
P Package detector A-29 Padding, Application Record, UCC/EAN-128 5-25 Palm Pilot A-15 Parity aux port 2-14 host port 2-5 Part Number 17-8 PDF Information 17-11 PDF417 5-20 PDF417 Decode Test 6-9 Percent PDF Read Rate Test 17-11 Percent Test 17-10 Pharma Code 5-27 Picket Fence Calculation Angled A-33 Raster A-32 Single Scan Line A-33 Pin Assignments A-6 Pitch A-28 Placeholder Character, Output Filtering 13-13 Point-to-Point standard 3-4 with RTS/CTS 3-5 with RTS/CTS & XON/XOFF 3-5 with XON/XOFF 3-5 Polling Mode D 3-5 Polling Sequence A-40 Position Scanner and Symbol A-28 Postamble Characters 3-13 Power A-6
MS-880 Industrial Long Range Scanner User’s Manual
I-5
Index
Object Detector A-29 Operating Life A-2 Operational Serial Commands 17-3 Operational Tips A-35 Optoelectric Database Modes 8-5 Optoelectrics by Embedded Menu 8-3 by ESP 8-2 by serial command 8-2 Ordered Output 13-11 Ordered Output/Filtering by embedded menu 13-12 by ESP 13-11 by serial command 13-12 Output 1 14-5 Output 2 14-10 Output 3 14-10 Output Circuit Samples A-9 Output Data 12-1 by ESP 12-3 Output Data Format 3-12 UCC/EAN-128 5-23 Output Filtering 13-11 Output Format/Filtering by embedded menu 13-3 by ESP 13-2 overview 13-4 Output Format/Filtering by Serial Command
13-2 Output Mode, discrete outputs 14-7 Output On, discrete outputs 14-5 Output, diagnostic 14-12 Output-1 17-13 Output-2 17-13 Output-3 17-13 Outputs by embedded menu 12-2 by serial command 12-2
Page 310
Index
Quality Output 12-11
Request Database Settings 7-5 Reset A-27 Reset Counts 14-4 Reset Flash Defaults to Active Memory A-24 Resets 15-12 Response Timeout 3-10 Restore Commands A-24 Restore Flash Defaults to Active Memory A-24 Restore Flash Defaults to Active Memory and for Power-on A-25 Restore NOVRAM Defaults to Active Memory A-24 Retrieve as Comparison 1-11 Retrieve Scanner Settings 1-10 RS-232 A-36 RS-422 A-36 RS422 Status 2-7 RS-485 A-36
R
S
Range 1-14, A-33 Raster Height A-34 Raster Settings by embedded menu 9-9 Raster Setup 9-3 Raster Sweep Rate 9-5, A-34 Raster/Laser by Embedded Menu 9-9 Raster/Laser Setup by Embedded Menu 9-2 by ESP Menus 9-2 by serial command 9-1 Read Cycle 4-13 by ESP 4-2 Read Cycle/Trigger by embedded menu 4-3 by serial command 4-2 Read Ranges A-3 Read Rate 17-10 Reads per Trigger Threshold 14-8, 14-9 Reads/Trigger Status 12-11 Remote Scanner ID 2-17
Safety Certifications A-5 Safety Labels i-xiii Save Active Settings except Factory for Power-on A-26 Save Active Settings including Factory for Power-on A-26 Save Commands A-24 Save Current Settings to Configuration Database 7-5 Saving 17-13, A-26 Scan Range 1-14 Scan Rate A-33 Scan Speed 10-4 Scan Width A-32, A-33 Scanner Range Range 1-12 Scanner Setting 6-9 Scanner Setup by embedded menu 10-3 by ESP 10-2 by serial command 10-2 Scanning Parameters A-3
Power (inside the wiring box) A-5 Power Connector A-7 Power connector 1-3 Power Supply 1-2 Powerups 15-12 Preamble Characters 3-12 Present Ambient Temperature 15-11 Profibus 3-15 ProfiBus DP A-37 Protocol 3-4 by embedded menu 3-3 by ESP 3-2 by serial command 3-2 Protocol Commands A-22 Pulse Width, discrete outputs 14-6 Pulse, discrete outputs 14-7
Index
Q
I-6
MS-880 Industrial Long Range Scanner User’s Manual