Operational Tips

Appendix N, Operational Tips Do: • Check inputs (label speed, length, height, etc.) to ensure the desired number of decodes per label. • For optimum decodes, mount scanner so that your labels pass through the center of the depth-of-field (minimum/maximum range). You find the center by moving your label in and out during a read rate test. • Avoid excessive tilt, pitch, and skew of the bar code label. • Check the bar code label for readability by doing a decode rate test. If there is any question about the label's readability, contact your Microscan representative at helpdesk@microscan.com. • After changing any parameter that might affect decode rate, repeat decode rate test. • Clean the scanner window with a clean, dry Q-tip or cotton cloth on a regular basis.

• Aim the scanner into direct light or sunlight. • Aim the scanner into an external object detector or other light-emitting device. • Obstruct the scanner window with mounting hardware or other objects. • Connect chassis of scanner and host to different ground potentials. • Operate the scanner in excessive temperature environments.

MS-880 Industrial Long Range Scanner User’s Manual

A-35

Appendices

Do Not:

Page 292

Appendix O

Appendix O, Interface Standards Interface Standards, established by the Electronic Industries Association (EIA), specify such things as the signaling voltage levels, maximum cable lengths, and number of drivers. With Microscan devices, selection of interface is made by pin assignment and, in the case of the host communications, by software switching between RS-232 and RS-422. Microscan devices use RS-232, RS-422, and RS-485 multidrop.

RS-232 RS-232 defines an interface between two devices such as, for example, the scanner and host. It differs from the other interfaces by dedicating individual pins to specific functions and by requiring both devices to share a common ground line. Since both device chassis are connected to a common ground, a ground loop potential and the possibility of noise interference exists. Therefore cable lengths are limited to a maximum of 50 feet (19.7m). Despite being the most limited, this interface is used frequently because of the large installed base of RS-232 equipment.

Appendices

RS-422 RS-422, unlike RS-232, measures signals deferentially; that is, the receiver looks at the potentials between the two receive (or transmit) wires rather than the potential between signal and ground. As a result, cables, if shielded, can be up to 4000 feet (1219m) in length. Like RS-232, RS-422 communication is designed for only two devices on a single line and must have a common ground. It can be used wherever RS-232 is used.

RS-485 RS-485, like RS-422, can transmit up to 4000 feet (1219 m) using differential voltages but unlike RS-422, its transmitters are turned off until a request for data is received from the host. RS-485 is used exclusively in multidrop protocol.

DeviceNet DeviceNet is a versatile, general purpose FieldBus designed to satisfy 80% of the most common machine- and cell-level wiring requirements. One of DeviceNet's major benefits is its multiple messaging formats, which allow the bus to 'work smart' instead of work hard.

A-36

MS-880 Industrial Long Range Scanner User’s Manual

Page 293

Interface Standards ProfiBus DP PROFIBUS is a vendor-independent, open field bus standard for a wide range of applications in manufacturing and process automation. Vendor-independence and openness are ensured by the international standards EN 50170 and EN 50254. PROFIBUS allows communication between devices of different manufacturers without any special interface adjustment. PROFIBUS can be used for both high-speed time critical applications and complex communication tasks.

Modicon Ethernet The Modicon Ethernet system consists of three basic elements: 1. the physical medium used to carry Ethernet signals between computers 2. a set of medium access control rules embedded in each Ethernet interface that allow multiple computers to fairly arbitrate access to the shared Ethernet channel 3. an Ethernet frame that consists of a standardized set of bits used to carry data over the system

DH485

MS-880 Industrial Long Range Scanner User’s Manual

A-37

Appendices

The DH485 network offers: intercommunication of up to 32 devices, peer-to-peer capability, the ability to add or remove nodes without disrupting the network maximum network length of 1219m (4000 ft.), can be extended to 2438m (8000 ft.) with 2 AIC+ units.

Page 294

Appendix P

Appendix P, Multidrop Communications This appendix describes the rules for setting up a concentrator or controller to communicate with a scanner in standard Multidrop protocol. The diagram to the right shows a typical Multidrop network in which 1 to 50 scanners can communicate with a host via an intermediary device, a concentrator or a controller.

Host Concentrator

Polled Protocol Multidrop ONLY RS-485 Interface

Scanner 01 Scanner 02 Scanner 03

Appendices

Configure Your Scanner for Multidrop 1. With the scanner connected to the host, do Retrieve Scanner Settings as in Step 5, “Retrieve Scanner Settings” on page 2-6. 2. Select Multidrop in the Protocol configuration menu. You will see the following message: Warning. You must change your preamble and postamble characters so that they are not CR or NULL.

This allows data to move through the concentrator without interference. 3. Click OK. 4. Next, go to Preamble Characters (still in the Protocol menu) and double-click on Characters. 5. This will open up an ASCII character table. Select any character other than CR. For example, select LF. 6. Repeat the above for Postamble. 7. Check the multidrop address. Enter a number from 01 to 50. 8. Right-click in the window and select Save to Scanner and Send and Save. 9. Your scanner is now in multidrop. From here on, you will need to use the concentrator to relay commands and data between the scanner or scanners and the host. 10. Next, go to “Connect to Scanner via the Concentrator” on page A-39.

A-38

MS-880 Industrial Long Range Scanner User’s Manual

Page 295

Multidrop Communications

Connect to Scanner via the Concentrator You will need a multidrop concentrator and the required power supplies and cabling to communicate with your scanner(s). 1. From the Communications drop down menu, select Configure Multidrop to bring up the Multidrop Settings dialog. 2. If necessary, change the default address to match the address of your multidropped scanner and click OK. If the host serial port is not connected in ESP, you will see the following popup message: ESP is not currently connected to the multidrop concentrator. Do you wish to establish a connection now?

3. Click Yes. You will see a Serial Communication Parameters dialog as shown on the next page. Notice that the Force Connection option is checked. Do not change this.

Appendices

4. Select the concentrator’s host port communications settings. When you click Connect, you will be connecting to your concentrator, which can then relay commands to the scanner whose address was set in the Multidrop Settings dialog. 5. Click Connect. 6. You should see the CONNECTED message in green at the bottom of the window along with the scanner’s Multidrop address.

7. Do Retrieve Scanner Settings to upload scanner’s configuration (Step 5). If upload fails, return to the Serial Communication Parameters dialog and make the corrections. 8. Follow the same procedure for connecting other scanners to your multidrop network. Note: For more information, see your scanner user’s manual or Microscan’s MS-5000 Multidrop Concentrator User’s Manual, 83-005000.

MS-880 Industrial Long Range Scanner User’s Manual

A-39

Page 296

Appendix P

Polling Sequence Data that is transmitted to the host (bar code data, noread messages, counters, etc.) via concentrators is solicited by poll requests from the host. The polling sequence example by poll address 1E (ASCII hex value for Scanner 02) and a REQ (request). The scanner responds by first transmitting its own address, 1E, followed by a STX (start of text) character, and then the data. Next it transmits an ETX (end of text) character and an LRC (longitudinal redundancy check) character. If the concentrator (or controller) receives the data from the scanner and is able to validate it with an LRC calculation, it responds with an ACK (acknowledgment). If the scanner in turn receives the ACK, the scanner ends this exchange with a RES (reset). Start of Sequence

Concentrator

Appendices

Scanner 02

End of Sequence

RES 1E REQ

ACK 1E STX DATA ETX LRC

RES

Figure A-11 Polling Sequence Polling Reset

• If the scanner has no information, it responds to a poll request by transmitting a RES (reset). • If the scanner receives a NAK instead of the ACK after transmitting its data string, it will re-attempt to send the data string up to three times. If the scanner still does not receive an ACK, it will send a RES (reset) and discard the data in its buffers. • If the scanner transmits data to the concentrator and the concentrator responds with an ACK or NAK, but the scanner doesn’t receive the concentrator’s response, the scanner will timeout and send a REQ to the concentrator and request another response. If after three retries (the number of times it transmits a REQ to the concentrator) the scanner receives no response, it ends the transmission with a RES (reset).

A-40

MS-880 Industrial Long Range Scanner User’s Manual

Page 297

Multidrop Communications

Select Sequence Unlike poll requests, select commands always originate from the host and consist of serial configuration or operation commands to devices that are configured in Multidrop. The scanner complies with the command when it is polled during the cycle. Start of Sequence

Concentrator RES 1F REQ Scanner 02

End of Sequence

STX <T>ETX LRC 1F ACK

RES 1F ACK

Figure A-12 Polling Sequence

Select Reset

If the scanner receives bad data from the concentrator, it transmits a SEL (its select address) and a NAK to the concentrator. The concentrator re-transmits the data up to three times. The concentrator will end the sequence with a RES (reset) if no ACK is received.

MS-880 Industrial Long Range Scanner User’s Manual

A-41

Appendices

A RES (reset) is the first command in the select sequence. The 1F hex is the select address associated with Scanner 02 address. It is followed by a REQ (request). The scanner responds with its own select address, 1F hex, and an ACK (acknowledge). The concentrator then transmits an STX (start of text), the data (in this case a <T>), an ETX (end of text), and an LRC character. The scanner replies by transmitting its own address, followed by an ACK, acknowledging receipt of the command. Upon receipt of an ACK, the concentrator concludes the successful exchange with a RES. In the example above, the scanner only acknowledges a trigger counter request from the concentrator. It does not respond to the trigger counter request until a subsequent poll. For example, if the scanner’s trigger count was 12 at the time the trigger counter request was received, on a subsequent poll it would send 02T/00012. (The 02 at the beginning of the string is the scanner’s address.)

Page 298

Appendix P Table A-11 Multidrop Addresses Multidrop Address

Appendices

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

A-42

Poll Character ASCII HEX ^\ 1C ^^ 1E SP 20 " 22 $ 24 & 26 ( 28 * 2A , 2C . 2E 0 30 2 32 4 34 6 36 8 38 : 3A < 3C > 3E @ 40 B 42 D 44 F 46 H 48 J 4A L 4C

Select Character ASCII HEX ^] 1D ^1F ! 21 # 23 % 25 ' 27 ) 29 + 2B 2D / 2F 1 31 3 33 5 35 7 37 9 39 ; 3B = 3D ? 3F A 41 C 43 E 45 G 47 I 49 K 4B M 4D

Multidrop Address 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50

Poll Character ASCII HEX N 4E P 50 R 52 T 54 V 56 X 58 Z 5A \ 5C ^ 5E ` 60 b 62 d 64 f 66 h 68 j 6A l 6C n 6E p 70 r 72 t 74 v 76 x 78 z 7A | 7C ~ 7E

MS-880 Industrial Long Range Scanner User’s Manual

Select Character ASCII HEX O 4F Q 51 S 53 U 55 W 57 Y 59 [ 5B ] 5D _ 5F a 61 c 63 e 65 g 67 i 69 k 6B m 6D o 6F q 71 s 73 u 75 w 77 y 79 { 7B } 7D D 7F

Page 299

Glossary of Terms

Appendix Q, Glossary of Terms

Bar Code Density. Number of characters per inch or other unit of measure. Baud Rate. The number of discrete signal events per second. Bits per second. Capture. The act of grabbing or recording a frame by an sensor. A frame or succession of frames that are captured. Channel. A high-speed pathway between the computer and the control units of the peripheral devices. Check Digit. A Modulus 43 or Modulus 10 digit that is added to the bar code message for additional data integrity. Command Processing. Allows the user to enter the ESP program from the auxiliary port or send serial string commands from the auxiliary port. Configuration. A setup or process of changing a scanner’s settings to conform to a specific application. Concentrator. Intermediary device that relays data from scanners to a host and commands from the host to the scanner or other devices.

MS-880 Industrial Long Range Scanner User’s Manual

A-43

Appendices

Active On (ION). An optoisolated input that’s logically “on” when current flows through the connection points. Active Off (IOFF). An optoisolated input that’s logically “on” when no current flows through the connection points. Analog Gain Adjustment (AGC). Adjustment to signal strength that seeks to maintain a constant level regardless of the range of the bar code label. Application Record. A variation of UCC/EAN-128 which adds an application identifier to label data, including user-definable separators, brackets, and padding. Autocalibration. A routine that cycles through various optical settings and selects the combination that produce the best read rate. Autodiscriminate. The ability to decode several different bar code symbologies without changing configuration. Auto Range. Outward focus of the scanner until an object is sensed by signal strength. The scanner then begins searching for a decodable label. Auxiliary Port. RS-232 connections to an auxiliary terminal or device for remote viewing. the transfer of data to and from the host, and under certain conditions a configuration port. Bar Code. The symbol used for recognition by a bar code scanner. An array of parallel bars and spaces of varying widths that conform to recognized standards and can be decoded and displayed as serial data. Bar Code Data. The information that is transmitted from a decoded bar code symbol. Bar Code Label. The physical media on which a bar code symbol is presented.

Page 300

Appendix Q Connector. Physical device (plug or socket) on a device or cable to provide in/out connectivity for various circuits and pins. Counter. Memory space provided to keep track of scanner events. Daisy Chain. Linkage of master and slave scanners to allow data to be relayed up to the host via auxiliary port connections. Decode. A good read. The successful scanning and decoding of the information encoded in a bar code label. Default. Restores ROM or Flash settings, initializes serial commands and resets all counters. Delimited. A command or field that is bracketed by pre-defined characters.

Appendices

Decode Rate. The number of good reads per second decoded by the scanner. Depth of Field. The distance between the minimum and maximum range in which a scanner can read bar code labels. Discrete I/O. Inputs and outputs characterized by discrete signal transitions from one voltage level to another so that digital switching can occur. EPROM. Erasable, programmable, read only memory. Embedded Memory. Onboard memory device such as EPROM or flash. End of Read Cycle. The time or condition at which the scanner stops expecting label information to decode. External Edge. Allows a read cycle to be initiated by a trigger signal from an object detector when it detects the appearance of an object (rising edge). The read cycle ends with a good read, a timeout, or a new trigger. External Level. Allows a read cycle to be initiated by a trigger signal from an object detector. The read cycle ends when the object moves out of the detector’s range. Falling Edge. A change of state (to inactive) associated with a level trigger in which the scanner stops searching for bar code symbols. (See Rising Edge.) Fixed Code Length. Increases data integrity by ensuring that only one label length will be accepted. Flash Memory. Memory that can be changed by downloading new code. Focal Length. The distance measured from the scanner to the center of the depth of field, or focal point. Focus. The point at which the tip of the scan beam is at its narrowest. Frame. The total area scanned in an image sensor. Full Duplex. Auxiliary port data is sent directly to the host but not displayed on the auxiliary port screen. Gain. Optimal signal strength. Good Read. A decode. The successful scanning and decoding of the information encoded in a bar code label. Half Duplex. Auxiliary port data is sent directly to the host and displayed on the auxiliary port screen.

A-44