Page 211

Chapter 14 Discrete I/0

Output 1 Definition: Usage:

Sets the discrete output functions for specific user-selected conditions. This option provides switching to host software to control external devices such as PLCs and relays. It is useful for routing and sorting and to prevent mis-packaging and mis-routing.

Output On Definition: Serial Cmd: Default: Options:

Allows the user to set the conditions under which an output (or outputs) will be activated. <K720,output on,active state,pulse width,output mode,trend analysis mode,trigger evaluation period,number to output on,reads per trigger threshold> Noread 0 = Mismatch Or Noread 1 = Match (or good read) 2 = Mismatch 3 = Noread 4 = Trend Analysis

Note: If Output On is set to Mismatch Or Noread, Match, or Mismatch, a transition (switching) will not occur unless Matchcode Type is enabled and a master label is loaded into memory.

Mismatch or Noread Definition:

Match Definition:

Activates a discrete output when the bar code data matches the master label. Note: If you want to output for a good read and Matchcode is not enabled, you can enable any output for Match.

Mismatch Definition:

Activates a discrete output whenever the bar code data does not match that of the master label.

MS-880 Industrial Long Range Scanner User’s Manual

14-5

14–Discrete I/0

Activates discrete output when the bar code data does not match that of the master label or the bar code has not been decoded before the end of the read cycle.

Page 212

Output 1 Noread Definition:

Activates a discrete output whenever the bar code data is not decoded before the end of the read cycle.

Trend Analysis Definition: Usage:

Activates discrete output when a trend analysis condition is met, depending on the trend analysis option enabled. Typically used when a discrete indication of a low read quality condition occurs.

Active State Definition: Serial Cmd: Default: Options:

Sets the active state of the discrete output. <K720,output on,active state,pulse width,output mode,trend analysis mode,trigger evaluation period,number to output on,reads per trigger threshold> Normally Open 0 = Normally Closed 1 = Normally Open

Pulse Width Definition:

14–Discrete I/0

Serial Cmd: Default: Options:

14-6

Sets the time in 10 mS increments that the discrete output remains active. <K720,output on,active state,pulse width,output mode,trend analysis mode,trigger evaluation period,number to output on,reads per trigger threshold> 5 (.05 seconds). Corresponds to 50 mS displayed in the menu. 1 to 255 (0.01 to 2.55 seconds). Divide the number entered on the command line by 100 for time in seconds.

MS-880 Industrial Long Range Scanner User’s Manual

Page 213

Chapter 14 Discrete I/0

Output Mode Definition: Serial Cmd: Default: Options:

Sets the condition in which the discrete output is de-activated. <K720,output on,active state,pulse width,output mode,trend analysis mode,trigger evaluation period,number to output on,reads per trigger threshold> Pulse 0 = Pulse 1 = Latch Mode 1 2 = Latch Mode 2

3 = Latch Mode 3

Pulse Definition:

This is the default mode of operation in which the programmable output is activated when the Output On condition has been met and held active for the duration of the selected pulse width.

Latch Mode 1 (Unlatch on Discrete Input 1) Definition:

The programmable output is active when the Output On condition has been met and held active until the discrete Input 1 has been activated.

Latch Mode 2 (Unlatch Opposite Condition) Definition:

The programmable output is activated when the Output On condition has been met and held active until the opposite condition selected under Output On has been met. For example, if Noread is enabled under Output On, the programmable output will go active upon a noread and remain active until the opposite condition, a good read, occurs.

Definition:

The programmable output is active when the Output On condition has been met and is held active until a new read cycle begins.

NOTE: All of the Output On modes are inhibited when any Output on Warning is active for Output 1 (see <K713> command).

MS-880 Industrial Long Range Scanner User’s Manual

14-7

14–Discrete I/0

Latch Mode 3 (Unlatch Enter Read Cycle)

Page 214

Output 1

Trend Analysis Mode Definition:

Sets the trend condition (Mismatch, Noread, or Reads/Trigger) that will activate the output. Parameters associated with Trend Analysis Mode are Number To Output On and Trigger Evaluation Period. The Number To Output On setting allows the user to select the number of times that the selected trend condition occurs before activating the output. Trigger Evaluation Period sets the number of triggered events to evaluate for trend condition. Example: Trend analysis mode = Noread Number to Output On =4 Trigger Evaluation Period=25

Usage: Serial Cmd: Default: Options:

In this example, the scanner will activate the output when 4 noreads occur within a period of 25 trigger events (read cycles). Useful in cases in which the user doesn’t want to shut down for one condition but wants to monitor quality and read conditions. <K720,output on,active state,pulse width,output mode,trend analysis mode,trigger evaluation period,number to output on,reads per trigger threshold> Noread 0 = Mismatch 1 = Noread 2 = Reads/Trigger

Mismatch 14–Discrete I/0

Definition:

Output will be activated when the number of Mismatches equals the value entered for Number to Output On within the trigger window selected in Trigger Evaluation Period.

Noread Definition:

The output will be activated when the number of noreads equals the value entered for Number to Output On within the trigger window selected in Trigger Evaluation Period.

Reads per Trigger Threshold Definition:

14-8

The Reads/Trigger trend monitors the number of good reads per triggered read cycle. If the number of Reads/Trigger falls below the value entered in Reads per Trigger Threshold, a trend condition is set. If this trend condition matches the number set in Number to Output On, the output will be activated.

MS-880 Industrial Long Range Scanner User’s Manual

Page 215

Chapter 14 Discrete I/0

Trigger Evaluation Period Definition: Serial Cmd: Default: Options:

The number of trigger events to examine within the trend analysis event. <K720,output on,active state,pulse width,output mode,trend analysis mode,trigger evaluation period,number to output on,reads per trigger threshold> 0 0 to 255

Number Before Output Definition: Serial Cmd: Default: Options:

Sets the number of events (matches, mismatches, or noreads as configured by Output On) that must occur before activating the associated output. <K720,output on,active state,pulse width,output mode,trend analysis mode,trigger evaluation period,number to output on,reads per trigger threshold> 0 0 to 255

Reads per Trigger Threshold Definition:

Serial Cmd: Default: Options:

MS-880 Industrial Long Range Scanner User’s Manual

14-9

14–Discrete I/0

Helpful Hints:

When Reads/Trigger trend analysis mode is enabled, the Reads per Trigger Threshold value is the minimum number of successful reads required during a read cycle. You can determine the expected number of scans during a read cycle by multiplying the enabled Number of Scans per second times the number of seconds in the read cycle. You can also use Quality Output (see “Quality Output”) to observe the number of successful reads. <K720,output on,active state,pulse width,output mode,trend analysis mode,trigger evaluation period,number to output on,reads per trigger threshold> 0 0 to 65,535

Page 216

Output 2

Output 2 Serial Cmd:

<K721,output on,active state,pulse width,output mode,trend analysis mode,trigger evaluation period,number to output on,reads per trigger threshold>

Output 2 has the same parameters and default settings as Output 1.

Output 3 Serial Cmd:

<K722,output on,active state,pulse width,output mode,trend analysis mode,trigger evaluation period,number to output on,reads per trigger threshold>

14–Discrete I/0

Output 3 has the same parameters and default settings as Output 1.

14-10

MS-880 Industrial Long Range Scanner User’s Manual

Page 217

Chapter 14 Discrete I/0

Diagnostic Outputs Note: See Chapter 15, “Diagnostics” for definitions and setup of Diagnostic Warnings. Definition: Usage: ESP:

Warning messages conditions relating to the MS-880 performance and environment can be programmed to activate selected outputs (Output 1, Output 2, or Output 3) whenever a warning condition occurs. Useful where output warnings of scanner malfunctions can be integrated to alert users and/or shut down a line. Click the Output Format and select the Diagnostic Outputs tab to bring up the table below:

Serial Cmd:

<K713,output #,status1,status2,status3,status4,status5,status6, status7,status8,status9> A <K?> command returns three separate verification responses, one for each output. A <K713?,n> command returns a verification response for one selected output (n=1,2,3). For example, in order to cause Output 3 to become active in response to any warning enabled message, issue this command: <K3,1,1,1,1,1,1,1,1,1>.

MS-880 Industrial Long Range Scanner User’s Manual

14-11

14–Discrete I/0

Double-click the appropriate cell under Outputs and enable/disable output in the popup on the left.

Page 218

Diagnostic Outputs

Output Definition: Function: Serial Cmd: Options:

Selects the status settings for one of three outputs (Output 1, Output 2, or Output 3). Each of the three outputs is independently associated with ten status settings. The settings can be accessed to verify/change one output at a time. <K713, output #,status1,status2,status3,status4,status5,status6, status7,status8,status9> 1 = Logic output 1 2 = Logic output 2 3 = Logic output 3

Status Definition: Serial Cmd: Default: Options:

When enabled, the error condition will cause the selected output to become active. <K713, output #,status1,status2,status3,status4,status5, status6,status7,status8,status9> Disabled (each can be independently enabled) 0 = Disabled 1 = Enabled status1 = Laser Current Low status2 = Laser Current High

14–Discrete I/0 status3 = Temperature Low status4 = Temperature High status5 = Diagnostics Flash Corrupt status6 = Laser Ref. Corrupt status7 = Product lifetime exceeded status8 = Factory settings defaulted status9 = Customer settings defaulted Note: When enabled, the error condition will override all other operational modes configured for the output.

14-12

MS-880 Industrial Long Range Scanner User’s Manual

Page 219

Chapter

Diagnostics

15 Chapter Contents Warning Messages ................................................................................15-4 High Temperature Threshold .................................................................15-8 Low Temperature Threshold..................................................................15-9 Lifetime Hours......................................................................................15-10 Present Ambient Temperature (deg. C)...............................................15-11 Counts .................................................................................................15-12 Time Since Last Reset.........................................................................15-13

This section describes warning and operating messages and their settings. Important: Since Warning Messages and NOVRAM Messages are not enabled by default, these messages will not be displayed. However, if you suspect that erroneous defaults are occurring, enable Warning Messages and NOVRAM Messages by sending <K400,1,,,1>.

MS-880 Industrial Long Range Scanner User’s Manual

15-1

15–Diagnostics

Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.

Page 220

Diagnostics by ESP Menu

Click this button to bring up the Diagnostic menu.

To change a setting, double-click the setting and use your curser to scroll through the options.

15–Diagnostics

Diagnostics by Serial Command Command Title

Old Cmds

Warning Message Status

K”

Lifetime Hours Over-temperature Under-temperature Laser Overcurrent Laser Undercurrent Power-on/Resets Counts Time Since Last Reset Present Operating Temperature

K$ K+ KK; K: K_ K@?

<K400,warning message status,laser high status,laser low status,novram/reset warning status> K401, <K401,hours10,message> K402, <K402,degrees,message> K403, <K403,degrees,message> K404, <K404,message> K405, <K405,message> K406, <K406,powerups,resets> K407? <K407?> returns: hours,minutes (read only)

K%?

K408? <K408?> returns: deg (read only)

15-2

New Cmds

Format

K400,

MS-880 Industrial Long Range Scanner User’s Manual