Chapter 13 Output Format and Filtering
Ordered Output/Filtering Definition:
Usage: Serial Cmd:
Ordered Output involves filtering and ordering. In the filtering stage, each label in a read cycle is read and matched against a user-defined table of up to 12 filters which search on code type, code length and data contents. A given label must meet all three criteria in any one of the filters in order to be included. In the ordering stage, labels are transmitted in the order that they match up with the filters. A label matching filter #1 will transmit first, another matching filter #2 will transmit next, and so forth. Useful in sorting several bar code labels into multiple categories with specific fields and a defined order of output. <K744,filter#,code type,length,wildcard character,placeholder character,data>
Ordered Output/Filtering by ESP 13–Output Format
Click on the Ordered Output tab.
Click on Send to send all settings to the scanner.
Double-click on this row to bring up the popup on the left for filter #1 Use this option to limit the code length
Type in data that you want the label to match Use this option to enter a control character on the Matching line above
This allows you to define the wildcard and placeholder
MS-880 Industrial Long Range Scanner User’s Manual
13-11
Page 202
Ordered Output/Filtering
Ordered Output/Filtering by Embedded Menu Embedded Menu:
Ordered Output/Filtering by Serial Command 13–Output Format
Filter # Definition: Serial Cmd: Default: Options:
The filter sequence number from 1 to 12 <K744,filter#,code type,length,wildcard character,placeholder character,data> 0 Range 1 to 12
Code Type Definition: Serial Cmd: Default: Options:
User-assigned code type that the scanner will search for. If a match is found, the scanner then checks Length. <K744,filter#,code type,length,wildcard character,placeholder character,data> 0 (Same as available in the Code Types setup menus)
Length Definition: Serial Cmd: Default: Options:
13-12
User-assigned code length that the scanner will search for. If the length is found, the scanner then checks Wild Card. <K744,filter#,code type,length,wildcard character,placeholder character,data> 0 (any length) 0 to 128
MS-880 Industrial Long Range Scanner User’s Manual
Page 203
Chapter 13 Output Format and Filtering Wildcard Character Definition:
Serial Cmd: Default: Options:
Wildcard Character indicates that any number of characters that follow the wildcard will be regarded as matches. For example, “123*” will match “123”, “123456”, “123ABC”, but not “12”. Filter data ”123*AB?C” will be interpreted as “123*” Both Wildcard Character and Placeholder Character can be mixed in the same filter data. <K744,filter#,code type,length,wildcard character,placeholder character,data> 2A (*) Any pairings of hex digits representing an ASCII character; for example, 2A = * (00 = disabled)
Placeholder Character
Serial Cmd: Default: Options:
Placeholder Character is a type of wild card that requires identical data position. For example, Filter data “123?”, will match all of the “1234”, “123A”, but not “123”, “12345”, “1234C”. Filter data “123?A” will match “1234A” and “123BA”, but not “123”, “1234C” or “1234ABCD” Both Wildcard Character and Placeholder Character can be mixed in the same filter data. <K744,filter#,code type,length,wildcard character,placeholder character,data> 3F (?) Any ASCII input as pair of hex digit; e.g., 3F=’?’ (00 = disabled)
Wildcard/Placeholder Matches Both Wildcard Character and Placeholder Character can be mixed in the same filter data. You can regard wildcard marks as the end of matching, whereas a placeholder requires identical data both before and after the placeholder.
MS-880 Industrial Long Range Scanner User’s Manual
13-13
13–Output Format
Definition:
Page 204
Ordered Output/Filtering For example: Filter data “123*” matches “123”, “123456”, “123ABC” but not “12”. Filter data “123*AB?C” will be interpreted as “123*” Filter data “123?A?” matches “1234AB”, “123BAT”, but not “1234A” or “123BATS”. Filter data “12??*” matches “1234”, “123456”, “123ABC”, but not “12”, “123”. Filter data “123?A*” matches “1234A”, “123BA”, “123BATS”, but not “1234”, “1234C”.
For example: <K745,1> enables Output Filters #1 setting. <K745,3> enables Output Filters #1 to filter #3’s setting. <K745,0> disables all output filters. The reader will not perform any filtered output.
Data
13–Output Format
Definition: Serial Cmd: Default: Options:
User-assigned data that the scanner will search for. <K744,filter#,code type,length,wildcard character,placeholder character,data> Null Any pairing of hex digits representing ASCII characters; e.g., 41422A = “AB*” (00 = disabled)
Number of Filters Definition: Serial Cmd: Default: Options:
The number of filters that labels will be compared against, up to the specified number. For example, entering 7 means that filters #1 through #7 will be enabled. <K745,number of filters involved> 0 0 to 12 Any number from 1 to 12 enables Output Filtering. A zero (0) disables Output Filtering. The reader will not perform any filtered output.
13-14
MS-880 Industrial Long Range Scanner User’s Manual
Page 205
Chapter 13 Output Format and Filtering Examples: Filter #1 Code type = Code 39, Length = disabled, Wildcard = ‘*’, placeholder = ‘?’, data = “AB*” = 41422A <K744,1,3,0,2A,3F,41422a>
Filter #2 Code type = Code 128, Length = 8, Wildcard = ‘*’, placeholder = ‘?’, data = “NBC??FGH” = 4e42433f3f464748. <K744,2,4,8,2A,3F,4e42433f3f464748> <K745,2> enables Ordered Output. It also enables filter#1 and filter#2. Let’s say we have four labels, “NBCXYFGH”, “NBDXYFGH”, “123XYZ”, “ABCDE”. The reader will registered two good reads only and transmit the following:“ABCDE”, “NBCXYFGH”.
13–Output Format
MS-880 Industrial Long Range Scanner User’s Manual
13-15
Page 206
Master Database in ESP
Master Database in ESP
13–Output Format
When you click the Master Database tab in the Output Format menu, you bring up a table for convenient entry of master label data for up to 10 entries. See “Master Label Database” on page 11-11 for details.
13-16
MS-880 Industrial Long Range Scanner User’s Manual
Page 207
Chapter
Discrete I/0
14 Chapter Contents Input 1 .......................................................................................................14-4 Output 1.....................................................................................................14-5 Output 2...................................................................................................14-10 Output 3...................................................................................................14-10 Diagnostic Outputs ..................................................................................14-11
Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.
MS-880 Industrial Long Range Scanner User’s Manual
14-1
14–Discrete I/0
This section includes instructions for setting up conditions for changing input/output electrical transitions for control of internal and external devices. A discrete I/O (in/ out) signal is an electrical transition from one voltage level to another so that digital switching can occur.
Page 208
Discrete I/O by ESP Menu
Click this button to bring up the Outputs menu.
To change a setting, double-click the setting and use your curser to scroll through the options.
Discrete I/O by Serial Command
14–Discrete I/0
Command Title old cmds
Diagnostic Output new cmds K713,
Format <K713,output#,status1,status2,status3,status4, status5,status6,status7,status8,status9> <K730, mode,active state> <K720,output on,active state,pulse width,output mode,trend analysis mode,trigger evaluation period,number to output on,reads per trigger threshold> <K721, output on,active state,pulse width,output mode,trend analysis mode,trigger evaluation period,number to output on,reads per trigger threshold> <K722, output on,active state,pulse width,output mode,trend analysis mode,trigger evaluation period,number to output on,reads per trigger threshold>
Input 1
KK
K730,
Output 1
Kv
K720,
Output 2
Kw
K721,
Output 3
K‘
K722,
Scanner I/O Status Request
KX?
K899? <K899?>
14-2
MS-880 Industrial Long Range Scanner User’s Manual
Page 209
Chapter 14 Discrete I/0
Discrete I/O by Embedded Menus For information on accessing the embedded menus, see “Embedded Menus” on page A-23. From the Main menu, scroll down through the options and select the following screen:
14–Discrete I/0
MS-880 Industrial Long Range Scanner User’s Manual
14-3
Page 210
Input 1
Input 1 Definition: Usage:
A programmable, discrete input used to reset counters, outputs or control optoelectrical settings. For example, an application is setup so that a mismatch stops the production line by using outputs in a latch mode (see “Output Mode”). A push button switch can be connected to the input pin so that when pressed, it unlatches the output, allowing the line to resume operations.
Input Mode Definition: Serial Cmd: Default: Options:
Determines the functionality of the input. <K730,input mode,active state> Disabled 0 = Disabled 1 = Reset Counts 2 = Unlatch Output
Disabled Definition:
When set to Disabled there is no effect on operation.
Reset Counts
14–Discrete I/0
Definition: Usage:
When set to Reset Counts, a transition to the active state of the input will cause the scanner to reset the internal counters. (See “File Transfer”). Primarily used in test mode. Can also be used to reset counters daily.
Unlatch Output Definition:
This setting is used in combination with any of the three discrete outputs that are in Unlatch Mode 1 (see “Latch Mode 1 (Unlatch on Discrete Input 1)” on page 14-7). A transition to the active state will clear any of the three outputs that were previously latched.
Active State Definition: Serial Cmd: Default: Options:
14-4
Sets the active level of the input pin. <K730,input mode,active state> Active Off (IOFF) 0 = Active On (ION)1 = Active Off (IOFF)