A two-page Microscan specification sheet (2001) for the MS-880 industrial automation scanner. It describes the features and lists read ranges, interfaces, connector pinouts, power, laser, scanning parameters, codes read and environmental limits.
- What it is
- Heavy duty industrial automation scanner with autofocus, reading linear codes and PDF417 p. 1
- Read range
- 10" to 35" on 7.5 mil labels up to 10" to 120" on 50 mil; 90" (228.6 cm) on 20 mil p. 2
- Interfaces
- RS-232, RS-422/485, IrDA port; daisychain/auxiliary port capable p. 2
- Fieldbus option
- DeviceNet, Profibus, Ethernet or Data Highway Plus through the optional IB-880 Wiring Box p. 2
- Connectors
- 25-pin D-sub host plug, 9-pin D-sub program plug, 3-pin MicroChange power, 4-pin MicroChange trigger p. 2
- Power
- 10-28 VDC, 230mA at 24 VDC typical, 200 mV p-p max. ripple p. 2
- Codes read
- Code 39, Code 128, UPC/EAN, Interleaved 2 of 5, Codabar, Code 93, PDF417, Pharma Code; AIAG, UCC/EAN-128 p. 2
- Laser
- Visible laser diode, 650 nm nominal; 50,000 hours operating life at 25°C p. 2
- Scan rate
- 400 to 1000 scans/second (default 500); rotating 14-faceted mirror; raster sweep 30° maximum p. 2
- Dimensions
- 3.5" (88 mm) L x 5" (127 mm) W x 6" (152 mm) H p. 2
- Temperature
- Operating 0° to 50°C (32° to 122°F); storage –50° to 75°C p. 2
- Enclosure
- IP65; humidity up to 90% non-condensing p. 2
- Programming
- ESP-MP software (Windows 95, 98, 2000, NT), embedded menus, serial commands, bar code programming; IrDA port p. 1
- Discrete I/O
- Trigger, New Master and Input 1 optoisolated 5-28V; Outputs 1, 2, 3 opto-isolated 10-28V p. 2
What this sheet walks you through
- Read range for each label size p. 2
- Pin assignments of the program, power and trigger connectors p. 2
- Wiring options of the IB-880 wiring box p. 1
Good to know
- Specifications are for typical performance at 25°C with grade A labels and may vary at temperature extremes. p. 2
- The laser label warns not to stare into the beam. p. 2
Questions this sheet answers
How far can the Microscan MS-880 read?
Out to 90 inches (228.6 cm) on a 20 mil label and 10" to 120" on a 50 mil label, measured with Code 39 grade A labels. p. 1, 2
What voltage does the MS-880 need?
10 to 28 VDC, drawing about 230mA at 24 VDC, through a 3-pin MicroChange power connector. p. 2
Does the MS-880 support DeviceNet or Profibus?
Yes, through the optional IB-880 Wiring Box, which also offers Ethernet and Data Highway Plus. p. 2
Can the MS-880 read PDF417?
Yes. It reads PDF417 and AIAG formats as well as standard linear codes. p. 1
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
Industrial Scanner 2D Reader Versatility and high performance have been built into ever y feature of the MS-880, providing the flexibility to solve a multitude of bar code scanning applications, under a variety of factory conditions. A heavy duty scanner designed for industrial automation, the MS-880 offers robust features including; wireless programming, autofocus, windows based software, linear and 2-D code reading, and multiple protocol options. The MS-880 is the ideal scanner for any facility looking to simplify equipment purchase by selecting one scanner model for use throughout the factory floor in a variety of applications. As bar code requirements change, adjustments can quickly be made to the scanner to fit the needs of the application.
INDUSTRIAL AUTOMATION SCANNER Long Read Range: The MS-880 optics were designed for successful reading at extended or varying distances, such as a safety or clearance zone required around conveyor or assembly areas. The MS-880 reads out to 90 inches (228.6 cm) on a 20 mil label. Autofocus: This setting is part of the autocalibration feature which automatically determines and selects optimal read settings for:
- Focus
- Gain
- Tracking
Programmable Raster: The scan area can be optimized for applications that may require:
- Reading multiple symbols
- Inconsistently placed labels
- Reading PDF417 code Optional Wiring Box, IB-880: Flexible and easy integration are attained without special cables or connectors. See the IB-880 specification sheet for complete details.
- Pluggable relay modules
- Terminal strip connectivity
- Connectivity with hand-held scanners
- Multiple protocol communications Integrated Industrial Protocols:
- DeviceNet
- Profibus
- Ethernet
- DataHighway Plus
Multiple Programming Methods: The MS-880 can be programmed while still on the line via a separate programming port, or the wireless IrDA port. Four programming methods:
Shown here with the wiring box option.
MS-880
Visible Read Indicators: Visible LEDs on the MS-880 show if the labels are being successfully read, allowing line workers to check the scanner’s performance instantly.
- ESP™-MP software (compatible with Windows 95, 98, 2000 and NT)
- Embedded menus
- Serial commands
- Bar code programming Wireless Communications: The IrDA port allows programming via palm computers and laptops. Bar Code Symbologies: The MS-880 reads PDF417 and AIAG formats, as well as all standard linear symbologies which include:
- Code 39
- UPC/EAN
- UCC/EAN-128
- Code 93
- Code 128
- Interleaved 2 of 5
- Codabar
- Pharma Code
Other codes are available; call Microscan more for details.
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
MS-880 INDUSTRIAL AUTOMATION SCANNER Specifications and Options READ RANGES1
MECHANICAL Length: 3.5" (88 mm) Width: 5" (127 mm) Height: 6" (152 mm) Weight: 4 lbs. (227 g)
Side1Label SizeScanning Distance7.5 mil (.190 mm)
10" to 35" (25.4 to 88.9 cm)
10 mil (.254 mm)
10" to 44" (25.4 to 111.8 cm)
15 mil (.381 mm)
10" to 74" (25.4 to 188 cm)
20 mil (.508 mm)
10" to 90" (25.4 to 228.6 cm)
30 mil (.762 mm)
10" to 100" (25.4 to 254 cm)
40 mil (1.020 mm)
10" to 110" (25.4 to 279.4 cm)
50 mil (1.27 mm)
10" to 120" (25.4 to 304.8 cm)
Readings are using a Code 39 grade A label
CONNECTORS/PIN ASSIGNMENTS
COMMUNICATION
Program Connector: 9-pin D-subminiature plug
Interface: RS-232, RS-422/485, IrDA port, Daisychain/auxiliary port capable. Interface with IB-880 Wiring Box (optional): DeviceNet, Profibus, Ethernet or Data Highway Plus
Pin No.FrontFunction2RX2323TX232CODE TYPES5Signal ground9Boot mode
Standard codes: Code 39, Code 128, UPC/EAN, Interleaved 2 of 5, Codabar, Code 93, PDF417, Pharma Code. Applications Standard: AIAG, UCC/EAN-128
Power Connector: 3-pin MicroChange Pin No.
ELECTRICAL
Function
Power Requirement: Input, 10-28 VDC, 200 mV p-p max. ripple, 230mA at 24 VDC (typ.)
1Power ground2NCEMISSIONS3
Power 10 to 28 VDC (in)
EN55022: 1998 Limits & Methods: ITE Disturbances (radiated and conducted) EN55024: 1998 (General Immunity: Residential) EN61000-6-2: 1999 (Heavy Industrial: Immunity)
Trigger Connector: 4-pin MicroChange Pin No.
BottomFunction1
Power 10 to 28 VDC (out)
2NPN3Ground4N/C
INDICATORS Beeper: Good read, match/mismatch, noread, serial command confirmation LEDs: 1 status, 1 power, 5 read performance (representing percentage of good decodes)
DISCRETE I/O
Host Connector: 25-pin D-subminiature plug
ENVIRONMENTAL Enclosure: IP65 Operating temperature: 0° to 50°C (32° to 122°F) Storage temperature: –50° to 75°C (–63° to 167°F) Humidity: Up to 90% (non-condensing)
LASER LIGHT Type: Semiconductor visible laser diode (650 nm nominal) Operating life: 50,000 hours @ 25°C (77° F) Safety class: CDRH Class II
SCANNING PARAMETERS Scanner mirror type: Rotating, single line, 14-faceted mirror Scan rate: Adjustable from 400 to 1000 scans/second (default = 500 sps) Raster Sweep Speed: 1 to 10 sweeps per second Raster Sweep Angle: 30° maximum Scan Width Angle: Typically 60° Pitch Angle: ±50° maximum Skew Angle: ±40° maximum Label contrast: 25% min. absolute dark to light differential at 650 nm wavelength
Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Host RS232
Host & Aux Host RS232 RS422/485 Chassis ground Host TxD Host RxD RTS Aux TxD CTS Aux RxD Output 1 (+) Signal Ground Output 2 (+) Trigger (–) Trigger (+) Default configuration Input 1 (+) RxD (+) TxD (–) Noread/Output 3 (+) RxD (–) Power Ground Power +10 to 28 VDC TXD + Output 1 (–) Output 2 (–) Noread/Output 3 (–) Input 1 (–) New master (–) New master (+)
In/ Out Out In Out In Out
Trigger, New Master, Input 1: Optoisolated, 5-28V rated, (12mA at 24 VDC) Outputs (1, 2, 3): Opto-isolated, 10–28V rated, (ICE<100 mA @ 24 VDC, current limited by user)
SAFETY CERTIFICATIONS Designed for FCC, CDRH, CE, UL/cUL, TüV, BSMI CAUTION LASER LIGHT
.
DO NOT STARE INTO BEAM
650 nm DIODE LASER 1.0 MILLIWATT MAXIMUM CLASS II LASER PRODUCT
Out In In In In In Out Out In In In Out Out Out Out In In In
ISO 9001/Cert. No. 00-1047 ©2001 Microscan Systems, Inc. 12/01 Specifications subject to change. Updates to this specification can be found on-line at www.microscan.com. Product specifications are given for typical performance at 25°C (77°F) using grade A labels. Some performance characteristics may vary at high temperatures or other environmental extremes.