The text of a manual · part 9 of 23
MS-850 Raster Scanner User's Manual, pages 81 to 90
Pages 81 to 90 of 222
The original document is the PDF (4.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-850
Page 81
Chapter 5 Codes
Check Digit Type (Codabar) Definition: Serial Cmd: Default: Options:
Modulus 16: NW 7:
Allows the user to select the check digit type Codabar will use. <Kqstatus,start & stop match,start & stop match output,large intercharacter gap,fixed code length status,fixed code length,check digit type,check digit output> Disabled 0 = Disabled 1 = Modulus 16 2 = NW 7 3 = Both Used in the photo-finishing market. Used in Japanese markets.
Check Digit Output (Codabar) Definition: Usage: Serial Cmd: Default: Options:
When enabled, the check digit character is sent along with the bar code data. When disabled, bar code data is sent without the check digit. For additional security a check digit can be added to the bar code symbol. <Kq status,start & stop match,start & stop match output,large intercharacter gap,fixed code length status,fixed code length,check digit type,check digit output> Disabled 0 = Disabled 1 = Enabled
5–Codes
MS-850 Raster Scanner User’s Manual
5-13
Page 82
Interleaved 2 of 5
Interleaved 2 of 5 Definition:
Usage:
A dense, continuous, self-checking, numeric symbology. Characters are paired together so that each character has five elements, two wide and three narrow, representing numbers 0 through 9, with the bars representing the first character and the interleaved spaces representing the second character. (A check digit is highly recommended.) Important: You must set Code Length in order to decode I 2/5 symbols. It is has been has been popular because it is the most dense code for printing numeric characters less than 10 characters in length; however Microscan does not recommend this symbology for any new applications because of inherent problems such as truncation.
Interleaved 2 of 5 Status Serial Cmd: Default: Options:
<Krstatus,check digit status,check digit output status,code length #1,code length #2,guard bar> Disabled 0 = Disabled 1 = Enabled
Check Digit Status (Interleaved 2 of 5) Definition: Usage: Serial Cmd: Default: Options:
An error correcting routine in which the check digit character is added. It is typically not used but can be enabled for additional security in applications where the host requires redundant check digit verification. <Krstatus,check digit status,check digit output status,code length #1,code length #2> Disabled 0 = Disabled 1 = Enabled
Check Digit Output (Interleaved 2 of 5) Definition:
5–Codes
Serial Cmd: Default: Options:
5-14
When enabled, a check digit character is sent along with the bar code data for added data security. <Krstatus,check digit status,check digit output,code length #1,code length #2,guard bar> Disabled 0 = Disabled 1 = Enabled
MS-850 Raster Scanner User’s Manual
Page 83
Chapter 5 Codes
Code Length #1 (Interleaved 2 of 5) Definition:
Usage: Serial Cmd: Default: Options:
Allows user to define the symbol length. Because I 2/5 is a continuous code, it is prone to substitution errors. Hence, a code length must be defined and a bar code symbol must contain an even number of digits. Note: If a start, stop or check digits are used, they are not included in the code length count. With I 2/5, two code lengths can be defined. When using only one symbol length in an application, setting Code Length #2 to 0 (zero) to ensure data integrity is recommended. <Kr status,check digit status,check digit output status,code length #1,code length #2,guard bar> 10 2 to 128, even. Since I 2/5 characters are paired, code length must be set to an even number. If Check Digit is enabled, add 2 to your code length. For example, if your symbol is 10 characters plus a check digit, then enable Code Length for 12. Note: Typically, when printing an I 2/5 label with an odd number of digits, a 0 will be added as the first character.
Code Length #2 (Interleaved 2 of 5) Definition: Usage: Serial Cmd: Default: Options:
Allows user to define a second code length for I–2 of 5. If using a second symbol, a zero or any even code length from 2 to 64 may be specified. If not using a second symbol, set Code Length #2 to 0 to ensure data integrity. <Kr status,check digit status,check digit output status,code length #1,code length #2,guard bar> 6 2 to 128, even. Since I 2/5 characters are paired, code length must be set to an even number. If Check Digit is enabled, add 2 to your code length. For example, if your symbol is 10 characters plus a check digit, then enable Code Length for 12. Note: Typically, when printing an I 2/5 label with an odd number of digits, a 0 will be added as the first character.
5–Codes
MS-850 Raster Scanner User’s Manual
5-15
Page 84
UPC/EAN
UPC/EAN Definition:
Usage:
UPC (Universal Product Code) is a fixed length numeric, continuous symbology. UPC can have two or five digit supplemental bar code data following the normal code. The U.P.C., Version A (U.P.C., A) symbol is used to encode a 12 digit number. The first digit is the number system character, the next five are the manufacturer number, the next five are the product number, and the last digit is the checksum character. When enabled, the scanner will read UPC version A and UPC version E only. Used primarily in POS application in the retail industry. It is commonly used with Microscan scanners in applications in combination with Matchcode when there is a need to verify that the right product is being placed in the right packaging.
UPC Status Serial Cmd: Default: Options:
<KsUPC status,EAN status,supplementals status,separator status,separator character> Disabled 0 = Disabled 1 = Enabled
EAN Status Definition:
Usage:
Serial Cmd:
5–Codes
Default: Options:
EAN is a subset of UPC. When enabled, the scanner will read UPC version A, UPC version E, EAN 13, and EAN 8. It also appends a leading zero to UPC version A symbol information and transmits 13 digits. If transmitting 13 digits when reading UPC version A symbols is not desired, disable EAN. Note: The extra character identifies the country of origin. EAN is the European version of the UPC symbology and is used in European market applications. Note: UPC must be enabled for EAN to take effect. <KsUPC status,EAN status,supplementals status, separator status, separator character> Disabled 0 = Disabled 1 = Enabled
5-16
MS-850 Raster Scanner User’s Manual
Page 85
Chapter 5 Codes
Supplementals Status (UPC/EAN) Definition:
Usage: Serial Cmd: Default: Options: Disabled: Enabled:
Required:
A supplemental is a 2 or 5 digit symbol appended to the main label. When set to Enabled or Required, the scanner reads supplemental bar code data that has been appended to the standard UPC or EAN codes. Reads Supplementals typically used in publications and documentation. <Ks UPC status,EAN status,supplementals status,separator status, separator character,> Disabled 0 = Disabled 1 = Enabled 2 = Required UPC Supplementals will not be decoded. When enabled, the scanner will try to decode a main and a supplemental. However, if a supplemental is not decoded, at the end of the read cycle, the main will be sent by itself. The UPC main and supplemental symbols are considered to be one symbol and will be treated as such. When set to Required and either the main or supplemental symbol is not read, a single noread condition results. The UPC main and supplemental symbols are treated as one symbol. For example, if Supplementals is set to Required, Separator is enabled, and an asterisk is defined as the UPC separator character, then the data will be displayed as: MAIN * SUPPLEMENTAL.
Note: Under no circumstances will supplemental symbol data be sent without a main symbol. Note: If additional symbols - other than the main or supplemental - will be read in the same read cycle, Number of Labels should be set accordingly.
Separator Status (UPC/EAN) Definition: Usage: Serial Cmd: Default: Options:
Allows the user to insert a character between the standard UPC or EAN code and the supplemental code when Supplementals is set to Enabled or Required. Allows user to distinguish between the main and Supplemental symbols. <Ks UPC status,EAN status,supplementals status,separator status,separator character> Disabled 0 = Disabled 1 = Enabled
5–Codes
MS-850 Raster Scanner User’s Manual
5-17
Page 86
UPC/EAN
Separator Character (UPC/EAN) Definition: Usage: Serial Cmd: Default: Options:
Allows the user to change the separator character from a comma to a new character. As required by the application. <KsUPC status,EAN status,supplementals status,separator status,separator character> , (comma) Any ASCII character
Note: If Separator Character has been changed to any other character and you wish to re-define the separator as a comma, you will need to use ESP or the embedded menu. Note: Whenever Separator Character is defined as a comma (,) sending a <Ks ?> command will return the current definitions including the separator character comma which will appear between two serial separator commas.
Supplementals Type (UPC/EAN) Definition: Usage: Serial Cmd: Default: Options: Both:
5–Codes
2 Char Only: 5 Char Only:
Allows the user to select 2 character or 5 character supplements, or both. As required by symbology used in application. <Ks UPC status,EAN status,supplementals status,separator status,separator character,supplemental type> Both 0 = Both 1 = 2 char only 2 = 5 char only Either 2 character or 5 character supplementals will be considered valid. Only two character supplementals will be considered valid. Only five character supplementals will be considered valid.
5-18
MS-850 Raster Scanner User’s Manual
Page 87
Chapter 5 Codes
PDF417 Definition:
Usage:
Serial Cmd:
A two-dimensional, multi-row (3 to 90), continuous, variable length symbology that has high data capacity for storing up to 2700 numeric characters, 1800 printable ASCII characters, or 1100 binary character per symbol. Each symbol character consists of 4 bars and 4 spaces in a 17-module structure. Used in applications where a large amount of information (over 32 characters) needs to be encoded within a symbol, typically where the symbol is transported from one facility to another. For example, an automobile assembly line might use a single label with multiple fields of information that will be read at several stations along the way, without reference to a database. <K[ status,raster sweeps before decode attempt,fixed code length status,fixed code length>
PDF417 Status Serial Cmd: Default: Options:
<K[ status,raster sweeps before decode attempt,fixed code length status,fixed code length> Disabled 0 = Disabled 1 = Enabled
Fixed Code Length (PDF417) Definition:
Usage:
When enabled, the PDF label must contain the same number of characters as the code length setting before it can be considered a good decode. The scanner will ignore any code not having the specified length. Used to increase data integrity by ensuring that only one label length will be accepted.
5–Codes
MS-850 Raster Scanner User’s Manual
5-19
Page 88
PDF417 Fixed Code Length Status (PDF417) Serial Cmd: Default: Options:
<K[ status,raster sweeps before decode attempt,fixed code length status,fixed code length> Disabled 0 = Disabled 1 = Enabled
Fixed Code Length (PDF417) Definition: Serial Cmd: Default: Options:
Specifies the exact number of characters the scanner will recognize. <K[ status,raster sweeps before decode attempt,fixed code length status,fixed code length> 10 1 to 2710
5–Codes
Note: Fixed Code Length Status must be enabled for Fixed Code Length to take effect.
5-20
MS-850 Raster Scanner User’s Manual
Page 89
Chapter 5 Codes
Code 128 Definition: Usage:
A very dense alphanumeric symbology. It encodes all 128 ASCII characters, it is continuous, has variable length, and uses multiple element widths measured edge to edge. Code 128 is a smaller code useful in applications with tight spots and high security needs.
Code 128 Status Serial Cmd: Default: Options:
<Kt status,fixed code length status,fixed code length> Disabled 0 = Disabled 1 = Enabled
Fixed Code Length Status (Code 128) Definition: Serial Cmd: Default: Options:
When enabled the scanner will check the label length against the code length field. If disabled any length would be considered a valid label. <Kt status,fixed code length status,fixed code length> Disabled 0 = Disabled 1 = Enabled
Fixed Code Length (Code 128) Definition: Usage: Serial Cmd: Default: Options:
It specifies the exact number of characters that the scanner will recognize (this does not include start and stop and check digit characters). The scanner ignores any code not having the specified length. Fixed Code Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted. <Kt status,fixed code length status,fixed code length> 10 1 to 128
Note: Fixed Code Length Status must be enabled for Fixed Code Length to take effect.
5–Codes
MS-850 Raster Scanner User’s Manual
5-21
Page 90
UCC/EAN-128
UCC/EAN-128 Definition: Usage:
A subset of Code 128, with extended features. See the Uniform Code Council, Inc. at www.uc-council.org. Used as a standard for shipping labels.
Note: Code 128 must be Enabled for UCC/EAN-128 to function.
UCC/EAN-128 Status Serial Cmd:
Default: Options: Enabled: Required:
<Kt,,,UCC/EAN-128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> Note: Code 128 serial command fields for K precede UCC/EAN-128. Disabled 0 = Disabled 1 = Enabled 2 = Required If Enabled, the scanner can read labels with or without a function 1 character in the first position. If set to Required, the label must have a function 1 in the first position and conform to EAN format in order to decode the bar code symbol.
Output Data Format (UCC/EAN-128) Definition: Usage: Serial Cmd: Default: Options: Standard:
5–Codes
Application Record:
Offers an option between Standard UCC/EAN-128 and Application Record format. Application Record is useful in applications in which the software can utilize application record formatting to help automate the processing of its UCC/EAN-128 data. <Kt,,,UCC/EAN-128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> Standard 0 = Standard 1 = Application Record In Standard UCC/EAN-128 application identifiers and data fields are sent, but none of the formatting (separators, parentheses, padding) will be included. Application Record is a variation of UCC/EAN-128 that allows the user to define separators between data fields, enclose application identifiers in parentheses, and enable padding (zeros) for variable length fields.
Note: If an illegal Application Record format is detected, the scanner will process it as a noread and output a noread message (if enabled).
5-22