Chapter 4 Read Cycle/Trigger
Trigger Filter Duration Definition:
Trigger Filter Duration can prevent trigger bounce from falsely triggering the scanner by limiting the time in which trigger pulses can be received.
Usage:
Trigger Filter Duration is useful where trigger bounce could cause false triggers.
Serial Cmd:
<Kg trigger mode,trigger filter duration>
Default:
78 (x 128 µs = 9984 µs)
Options:
0 to 65535 (corresponding to 0 to 2.048 s in 31.25 µs steps)
Good Decode Reads Definition:
The number of decodes (from 1 to 31) required per label before a label’s decoded data is sent. It requires the scanner to successfully decode a label a designated number of times (not necessarily consecutively) before it is sent. If it doesn’t achieve the number of good reads during the read cycle, then a noread will be sent. Note: Higher settings will decrease throughput speed.
Usage:
This is a very useful feature to increase reliability of reads for symbologies that do not have internal error checking such as Pharmacode.
Serial Cmd:
<Km decodes before output>
Default:
1
Options:
1 to 31
MS-850 Raster Scanner User’s Manual
4-9
4–Read Cycle/Trig-
Note: When setting up, be sure to determine if the scanner’s scan rate is capable of scanning your longest label the required number of times.
Page 62
External Trigger State
External Trigger State Definition:
When enabled for Active Off (IOFF) (Positive) the triggering device imposes a current on the optoisolator to activate the read cycle. When enabled for Active On (ION) (Negative) the triggering device interrupts the current to the optoisolator to activate the read cycle.
Usage:
Allows users to select the trigger state that will operate with their systems. (If using the Microscan object detector, use Active On.)
Serial Cmd:
<Kjexternal trigger state>
Default:
Active Off (Positive)
Options:
0 = Active On (Negative) 1 = Active Off (Positive)
4–Read Cycle/Trig-
Note: External Level, External Edge, or Serial Data or Edge trigger mode must be enabled for External Trigger to take effect.
4-10
MS-850 Raster Scanner User’s Manual
Page 63
Chapter 4 Read Cycle/Trigger
End of Read Cycle Definition:
The read cycle is the time during which the scanner will attempt to read and decode a bar code symbol.
Serial Cmd:
<Kh end of read cycle status,timeout>
End of Read Cycle Status A read cycle can be terminated by a new trigger, a timeout, or a combination of both.
ESP:
Double-click on End of Read Cycle Mode and make a selection.
Serial Cmd:
<Kh end of read cycle status,timeout>
Default:
Timeout
Options:
0 = Timeout 1 = New Trigger 2 = Timeout & New Trigger
Note: When operating in Continuous Read or Continuous Read 1 Output, the scanner is always in the read cycle.
MS-850 Raster Scanner User’s Manual
4-11
4–Read Cycle/Trig-
Definition:
Page 64
End of Read Cycle Timeout Definition:
Timeout ends the read cycle, causing the scanner to stop reading labels and send the label data or noread message when the time set in Timeout elapses (times out), if When to Output is set to End of Read Cycle. If in Continuous Read 1 Output, a timeout initiates a new read cycle and allows the same label to be read again. With either External Edge, Serial Data, or Serial Data & Edge enabled, a timeout ends the read cycle and label data or a noread message is sent to the host. With External Level enabled, the read cycle does not end until the falling edge trigger or a timeout occurs. The next read cycle does not begin until the next rising edge trigger. Typically used with Serial or Edge and Continuous One. It is effective in highly controlled applications when the maximum length of time between objects can be predicted. It assures that a read cycle ends before the next bar-coded object appears, giving the system extra time to decode and transmit the data to the host.
4–Read Cycle/Trig-
Usage:
4-12
MS-850 Raster Scanner User’s Manual
Page 65
Chapter 4 Read Cycle/Trigger New Trigger Definition:
New Trigger ends the current read cycle and initiates a new one when a new trigger occurs. New Trigger refers only to a “rising edge” trigger. With either External Edge, Serial, or Serial or Edge enabled, an edge or serial trigger ends a read cycle and initiates the next read cycle. In the case of External Level, a falling edge trigger ends the read cycle but the next read cycle does not begin until the occurrence of the next rising edge trigger. (See figure 4-1 on page 4-6 and figure 4-2 on page 4-7.)
Usage:
New Trigger is an effective way to end a read cycle when objects move past the scanner at irregular intervals (not timing dependent).
Note: When New Trigger is enabled, Laser On/Off will have no effect. When noreads occur, the laser will remain on.
Timeout or New Trigger Definition:
Timeout or New Trigger is identical to Timeout, except that a timeout or a new trigger (whichever occurs first) ends the read cycle.
Usage:
Useful in applications that require an alternative way to end the read cycle. For example, if an assembly line should stop completely or the intervals between objects are highly irregular.
Timeout Duration Timeout Duration is the time span of the read cycle and is represented in 10 mS increments. It is used in conjunction with External Edge or Serial Trigger.
Usage:
It is useful in many tightly controlled applications which require a read cycle to end before the next object appears and therefore need the flexibility of a timeout adjustment.
Serial Cmd:
<Khend of read cycle status,timeout>
Default:
100 (Corresponds to one second or 1000 ms.)
Options:
0 to 65535. (Divide any positive number entered by 100 to determine the time in seconds.)
Note: A minimum setting of 2 is recommended. Note: Timeout or Timeout or New Trigger under End of Read Cycle must be enabled for Timeout Duration to take effect.
MS-850 Raster Scanner User’s Manual
4-13
4–Read Cycle/Trig-
Definition:
Page 66
Multilabel
Multilabel Definition:
Multilabel allows the user to define up to 12 bar code labels that can be read in a single read cycle.
Usage:
Multilabel is commonly used in shipping applications where a shipping label contains individual bar codes for part number, quantity, etc. This feature allows one trigger to pick up all the labels. AIAG and UCC/EAN128 are two application standards that address this need.
Conditions
Allows you to choose the number of different labels that can be read in a single trigger event. The following conditions apply: 1. All noread messages are posted at the end of the data string. 2. If more than one label is within the scan beam at the same time, label data may not be displayed in the order of appearance. 3. If Matchcode Type is set to Sequential or if Trigger is set to Continuous Read 1 Output, Number of Labels will default to 1 (if set to any number greater than 1). 4. The maximum number of characters in any one bar code (other than PDF417) is 64. For PDF417 it’s 2710. 5. The maximum number of characters in a single scan line is 102 (Code 39). 6. The maximum number of characters for all labels is 788, including preamble, separators, and LRC.
4–Read Cycle/Trig-
Table 4-1 Maximum Number of Characters per Numbers of Labels
4-14
Number of labels
Non-PDF Labels Cumulative Maximum
1-5 6 7 8 9 10 11 12
333 398 463 528 593 658 723 788
PDF Labels Maximum Cumulative per label Maximum 2710 13563 2320 13961 2030 14225 1804 14448 1622 14615 1474 14758 1350 14869 1246 14972
MS-850 Raster Scanner User’s Manual
Page 67
Chapter 4 Read Cycle/Trigger
Number of Labels Definition:
Number of Labels is the number of different labels that can be read in a single read cycle.
Serial Cmd:
<KLnumber of labels,multilabel separator>
Default:
1
Options:
1 to 12
4–Read Cycle/Trig-
MS-850 Raster Scanner User’s Manual
4-15
Page 68
Multilabel
4–Read Cycle/Trig-
Multilabel Separator Definition:
The character that’s inserted between each label scanned when Multilabel is set to any number greater than 1.
Usage:
Used to delimit or separate data fields with a user defined character.
ESP:
Double-click on Separator and select a character in the popup window.
Serial Cmd:
<KLnumber of labels,multilabel separator> Note: If Multilabel Separator has been changed to any other character than the default comma and you wish to re-define the separator as a comma, use ESP (as shown below) or the embedded menu.
Default:
, (comma)
Options:
Any available ASCII character, except < > NUL.
4-16
MS-850 Raster Scanner User’s Manual
Page 69
Codes
Chapter
5 Chapter Contents Narrow Margins ...........................................................................................5-5 Symbology ID ..............................................................................................5-6 Background Color........................................................................................5-7 Code 39 .......................................................................................................5-8 Codabar.....................................................................................................5-11 Interleaved 2 of 5.......................................................................................5-14 UPC/EAN ..................................................................................................5-16 PDF417 .....................................................................................................5-19 Code 128 ...................................................................................................5-21 UCC/EAN-128 ...........................................................................................5-22 Code 93 .....................................................................................................5-25 AIAG ..........................................................................................................5-26 Autodiscriminate ........................................................................................5-28 This section describes the various bar code symbol types that can be read and decoded by the scanner. Code 39 is enabled by default. To enable all codes, right-click Autodiscrimination under Code Type in the Utilities menu and select Enable, or send a <P> serial command to the scanner from the Terminal window.1 Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.
5–Codes
See www.aimusa.org/standards for additional information about codes.
1. If using an I 2/5 label, verify that the number of characters in the label being scanned matches the code length enabled for the I 2/5 code type (default is 10 and 6). MS-850 Raster Scanner User’s Manual
5-1
Page 70
Code Types by ESP
Click this button to bring up the Code Types menu.
5–Codes
To change a setting, double-click the setting and use your curser to scroll through the options.
5-2
MS-850 Raster Scanner User’s Manual