Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 22 of 23

MS-850 Raster Scanner User's Manual, pages 211 to 220

Pages 211 to 220 of 222

The original document is the PDF (4.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan MS-850

Page 211

Glossary of Terms Connector. Physical device (plug or socket) on a device or cable to provide in/out connectivity for various circuits and pins. Counter. Memory space provided to keep track of scanner events. Daisy Chain. Linkage of master and slave scanners to allow data to be relayed up to the host via auxiliary port connections. Decode. A good read. The successful scanning and decoding of the information encoded in a bar code label. Default. Restores ROM or Flash settings, initializes serial commands and resets all counters. Delimited. A command or field that is bracketed by pre-defined characters. Decode Rate. The number of good reads per second decoded by the scanner. Depth of Field. The distance between the minimum and maximum range in which a scanner can read bar code labels. Discrete I/O. Inputs and outputs characterized by discrete signal transitions from one voltage level to another so that digital switching can occur. EPROM. Erasable, programmable, read only memory. Embedded Memory. Onboard memory device such as EPROM or flash.

Full Duplex. Auxiliary port data is sent directly to the host but not displayed on the auxiliary port screen. Gain. Optimal signal strength. Good Read. A decode. The successful scanning and decoding of the information encoded in a bar code label. Half Duplex. Auxiliary port data is sent directly to the host and displayed on the auxiliary port screen.

MS-850 Raster Scanner User’s Manual

A-37

Appendices

End of Read Cycle. The time or condition at which the scanner stops expecting label information to decode. External Edge. Allows a read cycle to be initiated by a trigger signal from an object detector when it detects the appearance of an object (rising edge). The read cycle ends with a good read, a timeout, or a new trigger. External Level. Allows a read cycle to be initiated by a trigger signal from an object detector. The read cycle ends when the object moves out of the detector’s range. Falling Edge. A change of state (to inactive) associated with a level trigger in which the scanner stops searching for bar code symbols. (See Rising Edge.) Fixed Code Length. Increases data integrity by ensuring that only one label length will be accepted. Flash Memory. Memory that can be changed by downloading new code. Focal Length. The distance measured from the scanner to the center of the depth of field, or focal point. Focus. The point at which the tip of the scan beam is at its narrowest. Frame. The total area scanned in an image sensor.

Page 212

Appendix N

Appendices

Host. A computer, PLC, or other device that is used to execute commands and process data and discrete signals. Host Port. The pins or connections on a scanner or other device that physically connect with a host and - using the RS-232, RS-422, or RS-485 standards - pass data and serial commands from one device to another. Initialize. Implement serial configuration commands into the scanner’s active memory. Input. A channel or communications line. Decoded data or a discrete signal that is received by a device. See Output. Intercharacter Delay. The time interval in milliseconds between individual characters transmitted from the scanner to the host. Intercharacter Gap. The extra space between the last element of one character and the first element of the adjacent character of a specific bar code symbol. IrDA. Infrared Data Association which promotes interoperable, infrared data interconnection standards. Label Height. Regardless of orientation, the measurement taken along the length of a label’s individual bars. Label Length. Regardless of orientation, the measurement taken across the label's bars from one end to the other, including the quiet zone. Label Speed (LS) is the distance per second that a label moves as it travels through the scan lines. Label Transitions. The transition of bars and spaces on a label, used to detect the presence of a label on an object. Ladder Label Orientation. A bar code label in which the bars are parallel to the label’s direction of travel. Large Intercharacter Gap. Allows the scanner to read symbols with gaps between bar code characters that exceed three times (3x) the narrow element width. Laser Framing. Setting scan width size by adjusting the on/off duration of the laser beam. Laser On/Off. When enabled, the laser is ON only during the read cycle, provided the scanner is enabled for a Serial or External trigger. LED. Light emitting diode. Longitudinal Redundancy Check (LRC). An error-checking routine that verifies the accuracy of transmissions. Master Scanner. First scanner in a daisy chain mode and linked directly to the host and in tandem to slave scanners. Matchcode. The ability to compare bar code labels being scanned against a master label that is stored in the memory of the scanner. Embedded Menu. Configuration options embedded in the scanner’s erasable memory. ESP-MP Menu. Easy Setup Program - Multiple Platform. Configuration program that runs in Windows-based operating systems 95 and above.

A-38

MS-850 Raster Scanner User’s Manual

Page 213

Glossary of Terms Mil. One thousandths of an inch or 0.0254 mm. In bar-coding, a measurement standard that identifies a bar code label by the width of its narrowest element. Mismatch. An event that occurs when the scanned bar code label does not match the master label that is stored in the memory of the scanner. Multilabel. A scanner mode which allows a scanner to read more than one bar code label in a single read cycle. Multidrop. A communications protocol for networking two or more scanners or other devices with a concentrator (or controller) and characterized by the use of individual device addresses and the RS-485 standard. Narrow-bar-width. The width of the narrowest bar of a given label, expressed in thousands of an inch (or mils). Narrow Margins. Allows the scanner to read symbols with quiet zones less than 8 times the width of the narrow bar element. Non-delimited. A command that is not bracketed by pre-defined characters.

MS-850 Raster Scanner User’s Manual

A-39

Appendices

Non-volatile RAM (NOVRAM). Random Access Memory that is available on poweron; that is, after power to the unit has been recycled. Noread. A non-read. A condition that occurs when the scanner is set up to decode labels but no label is scanned during the read cycle. Normally Closed. A discrete output state that is only active when open. Normally Open. A discrete output state that is only active when closed. NOVRAM. Non-volatile random access memory. Data that is saved for “power-on” is saved to NOVRAM. Number of Decodes. The number of times a bar code label is scanned by the scanner during one pass through the laser beam. Object Detector. A photo electric device used to sense the presence or absence of an object (also referred to as a package detector). Output. A channel or communications line. Data or discrete signals that are transmitted or displayed by a device. Output Format. The modification of data output according to a user-defined index of Extraction and Insertion commands. Parity. An error detection routine in which one data bit in each character is set to 1 or 0 (zero) so that the total number of 1 bits in the data field is even or odd. Picket Fence Label Orientation. A bar code label in which the bars are perpendicular to the label’s direction of travel. Pitch. Label (or scanner) rotation around the center of a line perpendicular to the label’s bars. Point-to-Point. A protocol consisting of a single communications event, typically used to connect a bar code scanner to a terminal or host computer. Port. Logical circuit for data entry and exit. (One or more ports may be included within a single connector.)

Page 214

Appendix N Protocol. The rules for communication between devices, providing a means to control the orderly flow of information between linked devices. Quiet Zones. Specified “clear” (non printed) areas immediately before and after the bar code symbol. The area is usually white (for black and white bar code) and at least 10 times the width of the narrowest bar, as measured in thousands of an inch. The zones can be other than white as long as their densities remain consistent and they have the required contrast relative to the bars. RAM. (Random Access Memory) Memory that is lost after power is recycled to the unit.

Appendices

Raster. Multiple, stacked scans produced by a separate oscillating mirror or by a spinning mirror with varying facet angles. Read Cycle. A programmed period of time or condition during which the scanner will accept bar code label input. Read Range. The distances in which a label can be reliably read, as measured from the front of the scanner. See “Depth of Field.” Relay. An electrical switch that allows a low power to control a higher one. Reset. Sets all counters to zero. Rising Edge. A change of state (to active) that initiates (and in some cases ends) a read cycle with a new trigger, an edge trigger, or the leading edge of a level trigger. (See Falling Edge.) ROM. (Read Only Memory) Memory that cannot be changed. Scanner. A scanning device that is comprised of a scan head and a decoder integrated in one package. Scan Rate (SR) The number of decodes per second that a given scanner is capable of casting. Scan Width (SW) is the width across the scan beam at a given distance from the scanner in which a label can be read. Send. Transmit data from one device to another. Separator. A character that separates data fields. Serial Commands. Online data strings such as <D> or <P> sent from a host or auxiliary terminal to a scanner or other device. Serial Configuration (Host Configuration). Serial command specifically for changing configuration and distinguished from operational command by the fact that they modify the non-volatile for power up configuration. Skew. Label (or scanner) rotation around the center of the skew axis. Slave Scanner. Linked to the master or preceding scanner in a daisy chain and relays bar code data to the host. See “Daisy Chain.” Specular Reflection Zone. The narrow zone straight out from the scanner in which direct reflected light from a label can distort the scanner’s ability to distinguish bars from spaces. Supplemental. A character or data string that is appended to the main bar code symbol.

A-40

MS-850 Raster Scanner User’s Manual

Page 215

Glossary of Terms Sweep. One pass of the raster, up or down. Sweep Rate (SwR) is the number of passes per second, up or down, describing the raster image. Symbol. A bar code. A decodable unit of information that is recognized by a bar code scanner. Symbology. A code type, such as Code 39 or Code 128, with special rules to define the widths and positions of bars and spaces to represent specific numeric or alphanumeric information. Symbology ID. An AIM standard prefix character that identifies the bar code type. Tilt. Label (or scanner) rotation around the centerline of the scan beam. Timeout. A user-selected period of time that ends a scanner's read cycle. Tracking. Adjustment of the precision of analog-to-digital conversion. Transmission. The transfer of data over a communications channel. Transmit. Send or convey signals or information from one device to another.

MS-850 Raster Scanner User’s Manual

A-41

Appendices

Transparent. Data is passed between the auxiliary port and the host with keyed data echoed to the auxiliary port Trigger. A signal, transition, or character string that initiates a read cycle. Watchdog Timer. A security device that detects system crashes and attempts to reset the scanner. Watchdog Reset. A reset that is forced whenever the software locks up. Wild Card. User-defined character entered into a master label to permit matches with variable characters.

Page 216

Appendices

Appendix N

A-42

MS-850 Raster Scanner User’s Manual

Page 217

Index C

25-pin host connector 1-3

Caution Summary i-xii CDRH i-x CE Compliance i-x Check Digit Codabar 5-13 Code 39 5-8 I 2 of 5 5-14 Checksum 12-9 Codabar 5-11 Code 128 5-21 Code 39 5-8 Code 93 5-25 Code Length I 2 of 5 5-15 Code Type 12-13 Code Types by Embedded Menu 5-4 by ESP 5-2 by serial command 5-3 COM1 1-6 Communication Protocol Commands A-17 Communications 2-1 by embedded menu 2-3 by ESP 2-2 by serial command 2-2 Communications Port 1-6 Communications, loss of A-22 Communications, Specifications A-3 Connect 1-7 Continuous Read 4-4 Continuous Read 1 Output 4-5 Continuous, AGC Mode 6-7 Control Characters A-15 Control/Hex Output 9-13 Counters 12-6 Counts 11-11 cUL i-x

A About This Manual i-x Active State, discrete outputs 10-5 AGC 6-6 AIAG (Automotive Industry Action Group) 5-26 AIAG Identifiers 5-27 Ambient Temperature 11-10 Application code 12-5 Application Record UCC/EAN-128 5-22 Application Record Brackets, UCC/EAN-128 5-23 Application Record Padding, UCC/EAN-128 5-24 Application Record Separator UCC/EAN-128 5-23 Approvals i-x As Soon As Possible, output 9-9 ASCII Table, including control characters A-16 Auto Connect 1-7 Autodiscriminate, Code Types 5-28 Aux Port Communications Parameters 2-12 Auxiliary Port 2-6

B Background Color 5-7 Bar Code Symbologies A-3 Baud Rate aux port 2-12 host port 2-4 Beeper A-4 Beeper Status 9-14 Bottom Offset 8-4 BSMI i-x

MS-850 Raster Scanner User’s Manual

I-1

Index

Numerics

Page 218

Index D

External Trigger State 4-10

Daisy Chain ID 2-13 Daisy Chain Mode 2-10 Data Bits aux port 2-12 host port 2-4 Decode Rate A-24, A-25 Decodes/Second Test 12-10 Default Commands A-19 Default Flash Defaults to Active Memory and for Power-on A-20 Default NOVRAM Defaults to Active Memory A-19 Defaulting 12-13 Defaulting/Saving/Initializing A-19 Device Control 12-12 Diagnostics by embedded menu 11-3 by ESP 11-2 by serial command 11-2 Disclaimer i-ii Discrete I/O by embedded menus 10-3 by ESP 10-2 by serial command 10-2 Download 12-5 Download code 12-5

F

Index

E EAN Status 5-16 EAN-128 5-22 Easy Setup Program i-ix Easy Setup Program - Multiple Platform 1-4 Electrical Specifications A-5 Emissions, Specifications A-2 End of Read Cycle 4-11 End of Read Cycle, output 9-10 End Read Rate Test 12-11 Enter Master Label Data 7-11 Environmental, Specifications A-2 ESP (Easy Setup Program) i-ix External Trigger Edge 4-7, 4-8 External Trigger Level 4-6

I-2

FCC i-x File Transfer 12-5 Fixed Code Length Codabar 5-12 Code 128 5-21 Code 39 5-9 Code 93 5-25 PDF417 5-19 Flash memory i-ix Formulas for Number of Decodes A-25 From Host 3-7 Full ASCII Set (Code 39) 5-10 Full Duplex Mode 2-9 Fully Optoisolated circuit A-7, A-9

G Gain A-28 Gain Adjustment 6-6 General Specifications A-2 Glossary of Terms A-36 Good Decode Reads 4-9 Good Read/Match Counter 12-6 Good Read/Match Counter Reset 12-7

H Half Duplex Mode 2-8 Hardware Required 1-2 Hex Output 9-13 High Temperature Threshold 11-7 Host Communications i-x Host Connector, 25-pin A-6 Host Port Parameters 2-4

I Immunity A-2 Initializing 12-13 Initializing (resetting) Commands A-22 Install ESP-MP 1-4 Intercharacter Delay 3-11 Interface A-3

MS-850 Raster Scanner User’s Manual

Page 219

Interface Standards A-30 Interleaved 2 of 5 5-14

K K Commands A-14 Keystrokes i-x

L

M Master Label 12-13 by ESP 7-10 Master Label Data Delete 7-13 Enter 7-11 Request 7-12 Request All 7-12 Store Next Label Scanned 7-14 Master Label Database 7-10, 12-13

N

Index

Label Density A-28 Label Dimensions A-28 Label Height A-25 Label Length A-26 Label Ratio A-28 Label Speed A-25, A-26, A-27 Ladder Calculation, single line A-25 Large Intercharacter Gap Codabar 5-12 Code 39 5-9 laser beam i-xii Laser Control 9-11 Laser Framing 9-11 Laser High Warning 11-5 Laser Light, Specifications A-2 Laser Low Warning 11-6 Laser On/Off Status 9-11 Laser Scanning 12-12 Laser Scanning, disable 12-12 Leading Edge, AGC Mode 6-7 Lifetime Hours 11-9 Longitudinal Redundancy Check 3-9 Low Temperature Threshold 11-8 LRC 3-9

Master Label Database Size 7-10 Match Counter 12-6, 12-7 Match Length 7-7 Match Start Position 7-6 Match, discrete outputs 10-4 Matchcode by embedded menu 7-3 by ESP 7-2 by serial command 7-2 Matchcode Type 7-5 Matchcode, overview 7-4 Mechanical A-2 Mirror Type A-2 Mismatch Counter 12-7 Mismatch Counter Reset 12-7 Mismatch or Noread, discrete outputs 10-4 Mismatch, discrete outputs 10-4 Model Selection 1-5 Motor Off 12-12 Motor On 12-12 Mounting Specifications A-4 Multidrop 3-6 Multidrop Addresses A-35 Multidrop Communications A-31 Multilabel 4-14 Multilabel Decode Rate Test 12-10 Multilabel Percent Test 12-10 Multilabel Separator 4-16

Narrow Margins 5-5 New Master Pin 7-15 New Trigger 4-13 No Bar Code Message 9-7 Noise Interference A-30 Noread Counter Reset 12-6 Noread Message, output 9-5 Noread, discrete outputs 10-4 Not Optoisolated A-9 NOVRAM/Default Warnings 11-4 Null Modem Cable 1-2 NULs, defining A-15 Number of Decodes A-24

MS-850 Raster Scanner User’s Manual

I-3

Page 220

Index Number of Labels 4-15

O Operating Life A-2 Operational Serial Commands 12-3 Operational Tips A-29 Output 1 10-4 Output 2 10-6 Output 3 10-6 Output Circuit Samples A-7 Output Data by ESP 9-3 Output Data Format 3-12 UCC/EAN-128 5-22 Output On, discrete outputs 10-4 Output-1 12-13 Output-2 12-13 Output-3 12-13 Outputs A-6 by embedded menu 9-2 by serial command 9-2

Index

P Padding, Application Record, UCC/EAN-128 5-24 Parity aux port 2-12 host port 2-4 Part Number 12-8 Partial Length 9-15 Partial Output 9-15 PDF Information 12-11 PDF417 5-19 Percent PDF Read Rate Test 12-11 Percent Test 12-10 Picket Fence Calculation Angled A-27 Raster A-26 Single Scan Line A-27 Pin Assignments A-5 Pitch A-23 Point-to-Point standard 3-4

I-4 with RTS/CTS 3-5 with RTS/CTS & XON/XOFF 3-5 with XON/XOFF 3-5 Polling Mode D 3-5 Polling Sequence A-33 Position Scanner and Symbol A-23 Postamble Characters 3-13 Power connector 1-3 Power Connector, 3-pin A-5 Power Supply 1-2 Powerups 11-11 Preamble Characters 3-12 Present Ambient Temperature 11-10 Protocol 3-4 by embedded menu 3-3 by ESP 3-2 by serial command 3-2 Protocol Commands A-17 Pulse Width, discrete outputs 10-5

R Range 1-11, A-27 Raster Height A-28 Raster Setup 8-3 Raster Sweep Rate 8-5, A-28 Raster/Laser Setup by Embedded Menu 8-2 by ESP Menus 8-2 by serial command 8-1 Read Cycle 4-11 by ESP 4-2 Read Cycle/Trigger by embedded menu 4-3 by serial command 4-2 Read Ranges A-3 Read Rate 12-10 Reset A-22 Reset Flash Defaults to Active Memory A-19 Resets 11-11 Response Timeout 3-10 Restore Commands A-19 Restore Flash Defaults to Active Memory A-19

MS-850 Raster Scanner User’s Manual