Page 181

Electrical Specifications

Optoisolator Outputs Optoisolator circuits can transfer pulses between the scanner and peripherals with no direct connection with the scanner’s internal circuitry. However, not every optoisolator configuration provides complete isolation. The following diagrams show both fully optoisolated and non-optoisolated circuits. They are only examples and do not represent all the possible wiring configurations. Generic Output Waveform Characteristics Iload =5mA Iload =50mA V Out-On

4.5V

Iload =100mA

11V

1.0V t On-Typ

30µS

20µS

30µS t Off-Typ

1000µS

150µS

75µS

Outputs (+)

Scanner Output

ILoad Outputs (–)

Output Circuit Examples Fully Optoisolated

Host

Isolated Scanner Power (+)

1 to 28 V Scanner

Outputs (+)

Output

Input Outputs (–) Power ground

Not Optoisolated, Scanner Grounded In this diagram, power is applied externally, but the scanner’s power ground is used to complete the circuit. This setup involves some risk to the optoisolator if excessive voltages are applied. Caution: The maximum current that can pass through the optoisolator is 100 mA.

Non-isolated Scanner

Host

Power (+) 1 to 28 V Scanner

Outputs (+)

Output

MS-850 Raster Scanner User’s Manual

Input Outputs (–)

Power ground

A-7

Appendices

This circuit is fully optoisolated and the recommended configuration. It allows the user to apply 1 to 28 VDC to the circuit. Caution: The maximum current that can pass through the optoisolator is 100 mA.

Page 182

Appendix B Additional Isolated Output Circuit Examples Secondary Relay 1 to 28 V

Scanner Output

Power +

Outputs (+)

Outputs (–) Power ground Outputs (–)

Appendices

Power ground

MS-850 Raster Scanner User’s Manual

V

PLC

Input

Outputs (+)

Output

A-8

PLC

Power +

RELAY

Isolated Scanner

Scanner

Isolated Scanner

PLC GND

Page 183

Electrical Specifications

Optoisolator Inputs All discrete inputs can be fully isolated pulses as PNP or NPN circuits. Inputs include trigger, new master, and other discrete inputs. Input-1 and Trigger Waveform Characteristics

New Master Pin Waveform Characteristics Minimum

Maximum

Minimum

Maximum

VIN-HIGH/IIN-HIGH

4.5 V/4mA

11 V/12mA

VIN-HIGH/IIN-HIGH

10 V/4mA

28 V/12mA

VIN-LOW/IIN-LOW

0 V/0mA

2.3V/2mA

VIN-LOW/IIN-LOW

0 V/0mA

5V/2mA

Pulse Widthmin

48 µS

Pulse Widthmin

48 µS

Note: Trigger pulses can be sent to the scanner either through the host 25-pin connector or a separate 4-pin trigger connector.

25-Pin Connector Input Examples Fully Optoisolated PNP Source +V

V CC

V CC

+V Input (+)

Signal Input (+)

Input (–)

Input (–)

Signal

Not Optoisolated PNP Source

Non-isolated Scanner V CC

Power (+) Input (+)

+V

NPN Source

Non-isolated Scanner V CC

Signal

Power (+)

+V

Input (+) Input (–)

Input (–)

Power ground

MS-850 Raster Scanner User’s Manual

Power ground

Signal

A-9

Appendices

Isolated Scanner

NPN Source

Isolated Scanner

Page 184

Appendix B 4-Pin Connector Trigger Input Example NPN Trigger Source Non-isolated

+V

+10 to 28 V V

Power (+) CC

Trigger (NPN) Signal

Appendices

Power (–)

A-10

MS-850 Raster Scanner User’s Manual

Page 185

Serial Configuration Commands

Appendix C, Serial Configuration Commands The following table is a list of all the available serial configuration commands. These commands are also listed at the beginning of each applicable chapter. For utility (operational) commands see Table 12-1, “Summary of Utility Serial Commands,” on page 12-3. Table A-6 Complete List of Serial Configuration Commands Cmd Ka

<Kabaud,parity,stop bits,data bits>

Format

Auxiliary Port Parameters

Ky

<Kyaux port mode,baud,parity,stop bits,data bits,daisy chain status,daisy chain ID>

Host Protocol

Kf

<Kfprotocol>

LRC

Kc

<Kcstatus>

Response Timeout

KA

<KAresponse timeout>

Intercharacter Delay

KB

<KBintercharacter delay>

Preamble

Kd

<Kdstatus,preamble>

Postamble

Ke

<Kestatus,postamble>

Comm. Status Request

KT?

<KT?>

Triggering Mode

Kg

<Kgtrigger mode,filter time>

End of Read Cycle

Kh

<Khmode,timeout>

Serial Trigger Character

Ki

<Kicharacter>

External Trigger State

Kj

<Kjexternal trigger state>

Decodes Before Output

Km

<Kmdecodes before output>

Multilabel

KL

<KLnumber of labels,multilabel separator>

Narrow Margins/Symbology ID

Ko

<Konarrow margins status,symbology ID status>

Background Color

Kx

<Kxbackground color>

Code 39

Kp

<Kpstatus,check digit status,check digit output status,large intercharacter gap,fixed code length status,fixed code length,full ASCII>

Interleaved 2 of 5

Kr

<Krstatus,check digit,check digit output,length 1,length 2>

UPC/EAN

Ks

<Ksstatus,EAN status,supplementals status,separator char>

PDF417

K[

<K[status,raster sweeps before decode attempt,fixed length status,fixed length>

Code 128

Kt

<Ktstatus,fixed length,length,,,,,,>

UCC/EAN-128 (subset of Code 128)

Kt

<Kt,,,UCC/EAN-128 status,output format,application record separator status,application record separator character,application record brackets,application record padding

Codabar

Kq

<Kqstatus,start & stop match status,start & stop output status,large intercharacter gap,fixed code length status,fixed code length,check digit type,check digit output>

Code 93

K!

<K!status,fixed code length status,fixed code length> MS-850 Raster Scanner User’s Manual

Appendices

Command Title Host Port Parameters

A-11

Page 186

Appendix C

Appendices

Command Title

Cmd

Format

AIAG

KZ

<KZAIAG status, ID1, status1, ID2, status2, ID3, status3, ID4, status4, *ID5a,ID5b,ID5c, status5, ID6, status6, ID7, status7, ID8, status8, ID9, status9, ID9, status10, ID11, status11, ID12, status12>

Code Type Status Request

KW?

<KW?>

Match Code Type

Kn

<Kntype,sequential matching,match start position,match length,wild card character,sequence on noread,sequence on every mismatch>

Master Label Data Base Size

KM

<KMnumber of master labels>

New Master Pin

Kz

<Kzstatus>

Operations Status Request

KV?

<KV?>

Background Color

Kx

<Kxbackground color

Code Type Status Request

KW?

<KW?>

Noread Message

Kk

<Kkstatus,output>

Laser On/Off

KC

<KCstatus,laser on/off status>

Serial Verification

KS

<KSserial command status,serial command beep status,control/hex output>

Beeper

Ku

<Kustatus,volume>

Output 2

Kw

<Kwoutput on,active state,pulse width,number before output>

Output 3

K‘

<K‘output on,active state,pulse width,number before output>

Output 1

Kv

<Kvoutput on,active state,pulse width,number before output>

Output 2

Kw

<Kwoutput on,polarity,pulse width,# before output>

Output 3

K‘

<K‘output on,polarity,pulse width,# before output>

Bar Code Output

Kl

<Klstatus,when to output>

Partial Output

KY

<KYstatus,start position,length>

Operational Command Output Format

K/

<K/status>

Scanner Output Status Request

KX?

<KX?>

Scanner Type (factory)

KP

<KPdensity>

Scan Speed (factory)

KE

<KEscan speed>

Gain/Tracking (factory)

KD

<KDgain,tracking>

Transition Trigger Sampling Rate

KH

<KHtransition sample status,transition sample rate threshold>

No Barcode Output

KN

<KNstatus,message>

Bad Barcode Output

K’

<K’status,message>

A-12

MS-850 Raster Scanner User’s Manual

Page 187

Serial Configuration Commands Command Title

Cmd

Scanner Setup Status Request

Format

KU?

<KU?>

Raster Setup

KR

<KRstatus,top offset,bottom offset,sweep rate,read cycle on/off>

Warning Message Status

K"

<K"status1,laserhi,laserlo,novram corrupt>

Laser Overcurrent

K;

<K;message>

Laser Undercurrent

K:

<K:message>

Over-temperature

K+

<K+deg,message>

Under-temperature

K-

<K-deg,message>

Lifetime Hours

K$

<K$hours10,message>

Present Operating TemK% perature

<K%deg> (read only)

Counts

K_

<K_powerups,resets> (read only)

Time Since Last Reset

K@

<K@hours,minutes> (read only)

All Status Request

K?

<K?>

Appendices

MS-850 Raster Scanner User’s Manual

A-13

Page 188

Appendix D

Appendix D, Serial Command Format Serial commands are of two types: utility and configuration.

Rules that apply to both utility and configuration commands • A less than < and greater than > characters enclose the commands. • Commands and data are “case sensitive.” That is, characters must be entered as upper or lower case, as specified.

Serial Utility Commands These are sent during operations and are not followed by a <A> or <Z>. See Table 12-1, “Summary of Utility Serial Commands,” on page 12-3.

Serial Configuration “K” Commands

Appendices

See Appendix D, “Serial Command Format” on page A-14. These begin with a single K character followed by a single character, data fields, and an initializing command, as follows: <Kparameterdata,data,...etc.><initializing command> An initializing command <A> or <Z> always follows the command. A <Z> initializes the scanner’s memory and saves for power-on; an <A> initializes the scanner’s memory but does not save for power-on. For example, to enable UPC and save the change for power-on, send <K1><Z>. To change Baud Rate and reset without saving changes for power-on, send <Ka3><A>.

Serial Configuration Command Conventions • All data fields (except the last) must be followed by a comma (without a space). • The following characters cannot be used: , < > NUL. • All fields preceding a modified field must be included. • If there is no change in preceding fields, then commas alone can be entered in these fields. For example, if only the last field in the following command is changing, <Ka4,1,0,0> can be entered as <Ka,,,0>. • All fields following a modified field can be omitted. For example, to change Baud Rate, send <Ka3>.

A-14

MS-850 Raster Scanner User’s Manual

Page 189

Serial Command Format Concatenating Configuration Commands Commands can be concatenated (added together) in a single string or data block.

Serial Command Status Request To ensure that any command was received and accepted, you can send the Show Scanner Status command: <?>. The status of a specific serial command can be requested by entering the command followed by a question mark.

Entering Special Characters in Serial Commands To enter control characters within a serial command, hold down the control key while typing the desired character.

Entering Special Characters in Embedded Menus Control Characters

To Define a Carriage Return as a Character Press SP, then CR. It is displayed as ^M on the command line and as <CR> in the menu when the screen is refreshed.

To Define a Space as a Character Press SP twice. It is displayed as a blank space in the menu when the screen is refreshed. While it appears that nothing has been assigned, the hex value 20 will be sent during data transmission.

To Select NUL as the Character Press SP, then a 0 (zero). It is displayed as <NUL> in the menu when the screen is refreshed.

MS-850 Raster Scanner User’s Manual

A-15

Appendices

Control characters entered on the command line are displayed in the menu as mnemonic characters, such as: <CR><LF><NUL><NUL>. Press SP (the space bar) once, then enter the control character by holding down the control key and simultaneously pressing the desired character. For example to define a line feed, press SP, then Control and J simultaneously. It is displayed as ^J on the command line and as <LF> in the menu when the screen is refreshed.

Page 190

Appendix E

Appendix E, ASCII Table

Appendices

Table A-7 ASCII Table with Control Characters Dec 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

A-16

Hex 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

Mne NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

Ctrl ^ ^A ^B ^C ^D ^E ^F ^G ^H ^I ^J ^K ^L ^M ^N ^O ^P ^Q ^R ^S ^T ^U ^V ^W ^X ^Y ^Z ^[ ^\ ^] ^^ ^_

Dec 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63

Hex 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F

Ch SP ! “ # $ % & ' ( ) * + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?

Dec 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95

Hex 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F

MS-850 Raster Scanner User’s Manual

Ch @ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _

Dec 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127

Hex 60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F

Ch ` a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ D