Page 101
Chapter 6 Scanner Setup
(factory setting) Definition:
Allows the user to set the number of scans per second by controlling the spinning mirror motor speed.
Usage:
Typically, to ensure a minimum number of scans, faster scan speeds are used for fast moving labels and/or longer labels with larger bar widths. Note: Scan beams will be moving faster across labels further out in the scan range since the moving beam is being projected from a spinning mirror.
Serial Cmd:
<KEscan speed>
Default:
50 (x 10 scans per second)
Options:
35 to 110 (x 10 scans per second)
MS-850 Raster Scanner User’s Manual
6-5
6–Scanner Setup
Scan Speed
Page 102
6–Scanner Setup
Gain Adjustment
Gain Adjustment (factory setting) Definition:
Sets a voltage amplitude value for the analog circuitry.
Usage:
Can be useful for fine-tuning gain or when portions of analog signals spike as in the case of specular reflection or extraneous noise. Caution: Changes to Gain are typically done by qualified technicians i.
Serial Cmd:
<KDgain,AGC sampling>
Default:
Default is 45 (nominal). Gain is optimized at the factory before shipment; the default value may not be 45.
Options:
10 to 255
6-6
MS-850 Raster Scanner User’s Manual
Page 103
Chapter 6 Scanner Setup
Definition:
AGC is the acronym for Automatic Gain Control. AGC increases the depth of field by attempting to maintain signal strength at a constant level regardless of the range of the bar code label. AGC Sampling allows you to specify how automatic gain control sampling will be done.
Serial Cmd:
<KDgain,AGC sampling>
Default:
Continuous
Options:
0 = Disabled
1 = Leading Edge
2 = Continuous
Disabled Definition:
When AGC Sampling is set to Disabled, gain levels can only be manually controlled by the Gain command (“Gain Adjustment” on page 66).
Usage:
Disabled is not recommended, but can be useful in certain applications in which labels do not require a large depth of field.
Leading Edge Definition:
Finds the leading edge of a symbol by looking for a 40 µs quiet zone followed by the number of transitions set in “Transition Counter Threshold” on page 6-8, stores the highest value of the samples, and adjusts the AGC accordingly at the end of the scan.
Usage:
Leading Edge is rarely used, but in some cases can improve scan rates when labels are skewed and the leading edge of a label is difficult to locate.
Continuous Definition:
Samples AGC throughout the scan at the rate set in “Transition Counter Threshold” on page 6-8, averages the sample values, and adjusts the AGC value at the end of the scan.
Usage:
Continuous is the default and the preferred mode for sampling analog signal amplitude.
MS-850 Raster Scanner User’s Manual
6-7
6–Scanner Setup
AGC Sampling
Page 104
6–Scanner Setup
Transition Counter
Transition Counter Used for both AGC and label detection routines (see Chapter 9, “Outputs”). Definition:
During the read cycle, the scanner counts the number of bar and space transitions defined in the Transition Counter. If the count matches or exceeds the threshold, the scanner will perform AGC routines. The results of this test are also made known in output messages. See “Bar Code Output,” on page 9-8 and “Bar Code Output,” on page 9-8.
Transition Counter Status Serial Cmd:
<KH transition counter status,transition counter threshold>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Transition Counter Threshold Definition:
Determines the number of bar/space transitions that must be read before a label is considered present and AGC can be resolved.
Usage:
Can be useful in certain application where extraneous objects in the field of view might require a higher threshold.
Serial Cmd:
<KH transition counter status,transition counter threshold>
Default:
14
Options:
1 to 255
6-8
MS-850 Raster Scanner User’s Manual
Page 105
Chapter
Matchcode
7 7–Matchcode
Chapter Contents Overview of Matchcode ...............................................................................7-4 Matchcode Type ..........................................................................................7-5 Master Label Database .............................................................................7-10 New Master Pin .........................................................................................7-15
This section explains the matchcode output functions and the master label database setup. Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.
MS-850 Raster Scanner User’s Manual
7-1
Page 106
Matchcode by ESP
7–Matchcode
Click this button to bring up the Matchcode menu. To change a setting, double-click the setting and use your curser to scroll through the options.
Matchcode by Serial Command Command Title Master Label Database Size cmds KM
Matchcode Type
Kn
New Master Pin Store next label scanned to database.a Enter data to database Request Master Label information Delete Master Label
Kz G M M? M
Format <KMnumber of master labels> <Kntype,sequential matching,match start position,match length,wild card character, sequence on noread,sequence on mismatch> <Kzstatus> <G> <Mmaster label number,data> <M?> <Mmaster label number,> a. If no number is included, the label will be saved to database number 1.
7-2
MS-850 Raster Scanner User’s Manual
Page 107
Chapter 7 Matchcode
Matchcode by Embedded Menu For information on accessing the embedded menus, see “Embedded Menus” on page A-18. From the Main menu, scroll down through the options and select the following screen:
7–Matchcode
MS-850 Raster Scanner User’s Manual
7-3
Page 108
Overview of Matchcode
7–Matchcode
Overview of Matchcode Definition:
With Matchcode you can store master label data in the scanner’s memory, compare this data against the scanned bar codes, and define how label data and/or discrete signal output will be directed. A master label database can be setup for up to 10 master labels. See “Master Label Database” on page 7-10. Note: Matchcode will function with multiple labels (see “Multilabel” on page 4-14); however if Matchcode Type is set to Sequential or if Triggering Mode is set to Continuous Read 1 Output, Number of Labels will default back to 1 (if set to any number greater than 1).
Usage:
Matchcode is used in applications to sort, route, or verify data based on matching the specific bar code label in a variety of ways as defined in this section. For example, a manufacturer might sort a product based on dates that are embedded in the bar code.
Steps for entering and using master labels 1. Set Triggering Mode to External or Serial (“Trigger Mode” on page 4-4). 2. Chose the method of label comparison that fits your application (“Matchcode Type” on page 7-5). 3. Define the output you want to achieve with your matchcode setup: a. Barcode output (“Bar Code Output” on page 9-8). b. Discrete output (“Output 1” on page 10-4, “Output 2” on page 10-6, and “Output 3” on page 10-6). 3. Select the number of master labels you want to create (“Master Label Database Size” on page 7-10). 4. Decide which of 4 ways you want enter your master label(s): a. Use ESP to type in master label data directly (“Enter Master Label Data” on page 7-11). b. Send a serial command with label data in the form of <Mmaster label#,data>. c. Send a <G> (Scan Next Label as Master Label) command. d. Enable the New Master Pin command (“New Master Pin” on page 7-15) and activate a discrete input to store the in the next label scanned as master label. 5. Enter master label data using the method determined in step 4.
7-4
MS-850 Raster Scanner User’s Manual
Page 109
Chapter 7 Matchcode
Matchcode Type Definition:
Allows the user to choose the way that master labels will be compared with subsequently scanned labels. Note: First set Triggering Mode to External or Serial.
ESP:
7–Matchcode
Serial Cmd:
<Kn matchcode type,sequential matching,match start position, match length,wild card character,sequence on noread,sequence on mismatch>
Default:
Disabled
Options:
0 = Disabled 1 = Enabled 2 = Sequential 3 = Wild Card
Disabled:
Has no effect on operations.
Enabled:
Instructs the scanner to compare labels or portions of labels with the master label.
Wild Card:
Allows the user to enter user defined wild card characters in the master label.
Sequential Matching:
Instructs the scanner to sequence after each match (numeric only) and compare labels or portions of labels for sequential numbers. Note: If Matchcode Type is set to Sequential, Number of Labels will default back to 1 (if set to any number greater than 1).
MS-850 Raster Scanner User’s Manual
7-5
Page 110
Matchcode Type
7–Matchcode
Sequential Matching Definition:
With Sequential enabled, Sequential Matching determines if a count is in ascending (incremental) or descending (decremental) order.
Usage:
Useful in tracking product serial numbers that increment or decrement sequentially.
Serial Cmd:
<Knmatchcode type,sequential matching,match start position, match length,wild card character,sequence on noread,sequence on mismatch>
Default:
Increment
Options:
0 = Increment 1 = Decrement
Match Start Position Definition:
Match Start Position determines the portions of labels that will be matched by defining the first character in the label (from left to right) that will be compared with those of the master label, when Matchcode Type is set to Enabled or Sequential.
Function:
For example, if Match Start Position is set to 3, the first 2 characters read in the symbol will be ignored and only the 3rd and subsequent characters to the right will be compared, up to the number of characters specified by Match Length.
Usage:
Match Start Position is useful in defining specific portions of a symbol for comparisons. For example, if a symbol contains a part number, manufacturing date, and lot code info but the user is only interested in the part number information. With Match Start Position the scanner can be set to only sort on the part number and ignore the rest of the characters.
Serial Cmd:
<Knmatchcode type,sequential matching,match start position, match length,wild card character,sequence on noread,sequence on mismatch>
Default:
0
Options:
0 to
Note: Match Start Position must be set to 1 or greater to enable this feature. A 0 setting will disable this feature.
7-6
MS-850 Raster Scanner User’s Manual