Two-page Microscan spec sheet (2002) for the MS-850 industrial raster scanner, which reads linear bar codes and PDF417. It gives the scan rate, raster settings, read ranges, code types, interfaces, power, connectors, size and operating limits.

What it is
Industrial raster scanner for linear and PDF417 labels, in a sealed IP65 die-cast aluminum case p. 1
Scan rate
Adjustable from 350 to 1100 scans/second (default 500) p. 2
Raster
Sweep angle set from 0 to 30 degrees; up to 30 sweeps per second p. 1
Code types
Code 128, Code 39, Code 93, Codabar, Interleaved 2 of 5, UPC/EAN, PDF417; AIAG and UCC/EAN-128 standards p. 2
Interfaces
RS-232, RS-422/485; SDS, DeviceNet, Profibus or Ethernet with an accessory protocol box; daisy chain/auxiliary port capable p. 2
Power
10-28 VDC, 200 mV p-p max. ripple, 140 mA at 24 VDC typical p. 2
Connectors
Host: 25-pin D-subminiature plug; trigger: 4-pin MicroChange; power: 3-pin MicroChange p. 2
Discrete I/O
Three opto-isolated programmable outputs, one trigger input, one programmable input p. 1
Laser
Visible semiconductor laser diode, 650 nm nominal; 50,000 hours operating life at 25°C p. 2
Read range
From 1.5" to 2.5" for .005" bars up to 6" to 30" for .040" bars, at 500 decodes per second, Code 39 grade A p. 2
Size and weight
4.28" high, 3.74" wide, 1.76" deep; 16 oz. (453 g) p. 2
Scan geometry
Scan width angle typically 60°; pitch ±50° max; skew ±40° max; 10-faceted rotating mirror p. 2
Environment
Operating 0° to 50°C (32° to 122°F); humidity up to 90% non-condensing p. 2
Match code options
Match Code, Noread, Mismatch, Sequential Matching, Wild Card Matching, Number of Good Reads p. 1

What this sheet walks you through

  • Comparing read ranges by bar width and label density p. 2
  • Host, trigger and power connector pin assignments p. 2
  • Raster sweep angle versus sweeps per second p. 2
  • Diagnostic controls for preventive maintenance p. 1

Good to know

  • SDS, DeviceNet, Profibus and Ethernet work only together with an accessory protocol box. p. 2
  • Specifications are typical performance at 25°C with grade A labels and may vary at high temperatures or other extremes. p. 2
  • The default host configuration is selected by connecting pin 11 to ground pin 7. p. 2

Questions this sheet answers

What power supply does the Microscan MS-850 need?

10-28 VDC with at most 200 mV p-p ripple; it draws about 140 mA at 24 VDC. p. 2

Can the MS-850 read PDF417?

Yes. It reads PDF417 as well as linear codes such as Code 128, Code 39, Code 93, Codabar, Interleaved 2 of 5 and UPC/EAN. p. 1, 2

How far away can the MS-850 read a bar code?

The sheet lists ranges up to 6" to 30" for .040" bars, measured at 500 decodes per second on a Code 39 grade A label. p. 2

Does the MS-850 support DeviceNet, Profibus or Ethernet?

Yes, through an accessory protocol box; RS-232 and RS-422/485 are built in. p. 2

How many scans per second does the MS-850 do?

The scan rate is adjustable from 350 to 1100 scans per second, with 500 as the default. p. 2

The file

Size and text

Pages2
PDF477 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Microscan MS-850 Spec Sheet

The text of page 1, from the PDF itself

Industrial Scanner 2D Reader The MS-850 boasts of customer-driven features. Foremost, its IP65 rated, heavy-duty, die-cast aluminum case and locking connectors ensure protection from extreme environmental conditions. This 16-ounce industrial raster scanner reliably scans multiple labels - and multiple symbologies - simultaneously at a user-adjustable rate between 350 and 1100 scans per second. The MS-850's programmable raster module allows further adjustments to both raster sweep angle and speed, providing the flexibility to scan a variety of label densities. Built-in mounting holes in the front and back of the scanner allow the MS-850 to be quickly mounted to any flat surface. The MS-850 is ideal for any industry using linear and/ or PDF417 labels in high speed and/or industrial environments. It is particularly well suited for packaging, electronics manufacturing, automotive manufacturing, and factory automation applications.

MS-850

INDUSTRIAL RASTER SCANNER Rugged IP65 Enclosure: Internal circuitry and optical components are protected from dust and moisture by a heavy-duty, industrial sealed die-cast aluminum case. MicroChange twist-lock connectors provide reliable and uninterrupted connection for the power and trigger ports.

Programmable Raster Mirror with Precise Sweeping Arc: The MS-850 raster module allows accurate mirror oscillation up to 30 sweeps per second. The raster sweep angle is also operator controlled from 0° to 30° providing extremely precise coverage.

Multiple Label and Symbology Reading: The MS-850 offers incredible flexibility not only in its ability to read multiple labels, but also multiple symbology types, both linear and PDF417.

Real-time Controls: Discrete input/output connections consisting of three opto-isolated programmable outputs, one trigger input, and one programmable input provide versatile programming options. Standard Microscan match code routines such as Match Code, Noread, Mismatch, Sequential Matching, Wild Card Matching, and Number of Good Reads allow for highly controlled automated data acquisition.

Preventive Maintenance Features: Diagnostic controls monitor the operating conditions of the MS-850. Ultimately, these controls - relating to

Bar Code Symbologies: The MS-850 scans multiple symbologies, including PDF417 and all widely used linear bar code symbologies.

  • Interleaved 2 of 5
  • PDF417
  • Code 39
  • Code 93
  • Code 128
  • Codabar
  • UPC/EAN Applications Standards
  • UCC/EAN-128
  • AIAG

Other codes are available, call Microscan for details.

the operating life and temperature, laser current levels, and frequency of power-ups - help prevent costly downtime. For example, user defined messages alert the operator when thresholds have been exceeded and allow for intervention before problems arise.

Service Options:

  • Installation assistance program
  • Service agreements
  • Training
  • On-site service
  • Extended warranty
Page 2 of Microscan MS-850 Spec Sheet

The text of page 2, from the PDF itself

MS-850 INDUSTRIAL RASTER SCANNER Specifications and Options MECHANICAL

READ RANGES1

Height: 4.28" (10.9 cm) Width: 3.74" (9.5 cm) Depth: 1.76" (4.5 cm) Weight: 16 oz. (453 g)

Narrow-bar-widthHigh Density.005" (.127 mm)

1.5" to 2.5" (3.81 to 6.35 cm)

.0075" (.190 mm)

1" to 3.5" (2.54 to 8.89 cm)

Narrow-bar-widthMedium Density.0075" (.190 mm)

2.5" to 5" (6.35 to 12.7 cm)

.010" (.254 mm)

1" to 6" (2.54 to 15.24 cm)

Medium and High Density

.015" (.381 mm)

1" to 8" (2.54 to 20.32 cm)

.020" (.508 mm)

1" to 11" (2.54 to 27.94 cm)

.030" (.762 mm)

1" to 14" (2.54 to 35.56 cm)

Narrow-bar-widthLow Density.015" (.381 mm)

6" to 15" (15.24 to 38.1 cm)

.020" (.508 mm)

6" to 20" (15.24 to 50.8 cm)

.030" (.762 mm)

6" to 24" (15.24 to 60.96 cm)

.040" (1.02 mm)

6" to 30" (15.24 to 76.2 cm)

Low Density

1.

At 500 decodes per second using Code 39 grade A label.

CODE TYPES Standard Offerings: Code 128, Code 39, Code 93, Codabar, Interleaved 2 of 5, UPC/EAN, PDF417 Applications Standards: AIAG, UCC/EAN-128

CONNECTORS/PIN ASSIGNMENTS Host Connector: 25-pin D-subminiature plug Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

ENVIRONMENTAL Enclosure: Cast aluminum IP65 Operating temperature: 0° to 50°C (32° to 122°F) Storage temperature: –50° to 75°C (–63° to 167°F) Humidity: Up to 90% (non-condensing)

EMISSIONS Heavy industrial: EN 61000-6-2:1999 Radiated emission: EN 55022:1998 Class A 30-1000 MHz Conducted emissions: EN 55022:1998 Class A 0.15-30 MHz Noise immunity: IEC 801-4 level 3

LASER LIGHT Type: Semiconductor visible laser diode (650 nm nominal) Operating life: 50,000 hours @ 25°C Safety class: CDRH Class II

SCANNING PARAMETERS Scanner mirror type: Rotating, 10-faceted Scan rate: Adjustable from 350 to 1100 scans/second (default = 500 sps) Scan width angle: Typically 60° Pitch: ±50° maximum Skew: ±40° maximum Label contrast: 25% min. absolute dark to light differential at 650 nm wavelength Raster mirror performance: Raster sweep angle

1°–10° 11°–20° 21°–30° (max.)

Maximum sweeps per second

30 20 10

COMMUNICATION Interface: RS-232, RS-422/485, *SDS, *DeviceNet, *Profibus, *Ethernet, daisy chain/ auxiliary port capable

  • Used in conjunction with an accessory protocol box.

a

Host RS232

Host & Aux Host RS232 RS422/485 Chassis ground Host TxD Host RxD RTS Aux TxD CTS Aux RxD Output 1 (+) Signal Ground Output 2 (+) Trigger (–) Trigger (+) Default configuration a Input 1 (+) RxD (+) TxD (–) Noread/Output 3 (+) RxD (–) Power Ground Power +10 to 28 VDC TXD + Output 1 (–) Output 2 (–) Noread/Output 3 (–) Input 1 (–) New master (–) New master (+)

In/ Out Out In Out In Out

ELECTRICAL Power Requirement: 10-28 VDC, 200 mV p-p max. ripple, 140 mA at 24 VDC (typ.) Trigger, New Master, Input 1: Optoisolated, 5-28V rated, (12 mA at 24 VDC) Outputs (1, 2, 3): Optoisolated, 10-28 VDC rated, (ICE <100 mA at 24 VDC, current limited by user)

SAFETY CERTIFICATIONS FCC, CDRH, CE, UL/cUL, TüV, BSMI

Out In In In In In Out Out In In Out Out Out Out In In In

ISO 9001/Cert. No. 00-1047 ©2002 Microscan Systems, Inc. 01/02 Specifications subject to change. Updates to this specification can be found on-line at www.microscan.com. Product specifications are given for typical performance at 25°C (77°F) using grade A labels. Some performance characteristics may vary at high temperatures or other environmental extremes. Warranty–One year limited warranty on parts and labor. Extended warranty available.

The default is activated by connecting pin 11 to ground pin 7.

Trigger Connector: 4-pin MicroChange Pin No. 1 2 3 4

Function Power + 10 to 28 VDC NPN Power Ground NC

In/Out Out

Microscan Systems, Inc. Tel 425 226 5700 / 800 251 7711 Fax 425 226 8250

Microscan Europe Tel 31 172 423360 / Fax 31 172 423366

Microscan Asia Pacific R.O. Power Connector: 3-pin MicroChange Pin No. 1 2 3

Function Power ground NC Power + 10 to 28 VDC

Tel 65 6846 1214 / Fax 65 6846 4641 In/Out

Part of a full range of sales tools available from our web site:

www.microscan.com E-mail: helpdesk@microscan.com In