Page 71
Chapter 5 Codes
Code Types by Serial Command Command Title cmds
Narrow Margins/Symbology ID Background Color
Format
Ko
<Konarrow margins status,symbology ID status>
Kx
<Kxbackground color> <Kpstatus,check digit status,check digit output status,large intercharacter gap,fixed code length status,fixed code length,full ASCII> <Kqstatus,start & stop match status,start & stop output status,large intercharacter gap,fixed code length status,fixed code length,check digit type,check digit output> <Krstatus,check digit,check digit output,length 1,length 2> <Ksstatus,EAN status,supplementals status,separator char.> <K[status,[usused],fixed code length status,fixed code length> <Ktstatus,fixed length,length> <Kt,,,EAN-128 status,output format,separator status,separator character,application identifier parentheses,record padding> <Kt,,,UCC/EAN-128 status,output format,application record separator status,application record separator character,application record brackets,application record padding <K!status,fixed code length status,fixed code length> <KZAIAG status, ID1, status1, ID2, status2, ID3, status3, ID4, status4, *ID5a,ID5b,ID5c, status5, ID6, status6, ID7, status7, ID8, status8, ID9, status9, ID9, status10, ID11, status11, ID12, status12>
Code 39
Kp
Codabar
Kq
Interleaved 2 of 5
Kr
UPC/EAN
Ks
PDF417 Code 128
K[ Kt
EAN-128
Kt
UCC/EAN-128 (subset of Code 128)
Kt
Code 93
K!
AIAG
KZ
Code Type Status Request
KW?
<KW?>
5–Codes
MS-820 Industrial Bar Code Scanner User’s Manual
5-3
Page 72
Code Types by Embedded Menu
5–Codes
For information on accessing the embedded menus, see “Embedded Menus” on page A-19. From the Main menu, scroll down through the options until you reach the following screens:
5-4
MS-820 Industrial Bar Code Scanner User’s Manual
Page 73
Chapter 5 Codes
Narrow Margins Definition:
Usage: Serial Cmd: Default: Options:
Allows the scanner to read symbols with quiet zones less than 8 times the width of the narrow bar element. “Quiet zone” is the space at the leading and trailing ends of a symbol. Each quiet zone can be as narrow as only five times the width of the narrow bar element when Narrow Margins is enabled. Used when the leading and trailing edges of the symbols are smaller than the standard margin or other objects encroach into the margins. <Konarrow margins status,symbology identifier> Disabled 0 = Disabled 1 = Enabled
Note: Do not use Narrow Margins with Large Intercharacter Gap enabled in Code 39 or Codabar.
5–Codes
MS-820 Industrial Bar Code Scanner User’s Manual
5-5
Page 74
Symbology ID
Symbology ID Definition:
Symbology ID is an AIM standard prefix character that identifies the bar code type. When enabled, the scanner analyzes and identifies the bar code symbology and adds a three character identifying prefix to the data: 1. ] (close bracket character) indicating the presence of a symbology ID 2. A, C, E, F, G, I, L, Q A = Code 39; C = Code 128 or UCC/EAN-128; E = UPC/EAN; F = Codabar; G = Code 93; I = I–2 of 5; L = PDF417; Q = Pharma Code 3. Modifier, a single number indicating the status of the check digit character:
Usage: Serial Cmd: Default: Options:
If Check Digit is not enabled, the output is 0 (Col. 1). If Check Digit and Check Digit Output are enabled, the output is as shown in Column 2. If Check Digit is enabled, but Check Digit Output is disabled (Col. 3), the output is as shown in Col. 4, which is the sum of Col. 2 and Col. 3. Used when host needs to know the symbology type and how it’s decoded. <Ko narrow margins status,symbology identifier> Disabled 0 = Disabled 1 = Enabled
Example: For Code 39, if Check Digit and Check Digit Output are both enabled, a 1 will be sent; if Check Digit Output is disabled, a 3 (sum of column 1 and column 2) will be sent. Table 5-1 Symbology Identifier Option Values Symbology
Column 1 No check character
A C C E F G I L Q
Code 39 Code 128 UCC/EAN-128 UPC/EAN Codabar Code 93 I–2 of 5 PDF417 Pharma Code
0 0 0 0 0 0 0 0 0
5–Codes
Symbology I.D.
5-6
Column 2 Check digit Output enabled 1 0 0 0 1 0 1 0 0
Column 3 Check digit Output disabled 2 0 0 0 2 0 2 0 0
MS-820 Industrial Bar Code Scanner User’s Manual
Column 4 Sum of Column 2 and 3 3 0 0 0 3 0 3 0 0
FNC 1 Character in first position
1
Page 75
Chapter 5 Codes
Background Color Definition: Usage:
Allows the user to choose which symbol background (white or black) the scanner can read. If the background is darker than the symbol, then enable black background. Typically the background is white; but on PCBs for example, they can be black.
ESP:
Serial Cmd: Default: Options:
<Kx background color> White 0 = White 1 = Black
5–Codes
MS-820 Industrial Bar Code Scanner User’s Manual
5-7
Page 76
Code 39
Code 39 Definition: Usage:
An alphanumeric code with unique start/stop code patterns, composed of 9 black and white elements per character, of which 3 are wide. Code 39 is considered the standard for non-retail symbology.
Code 39 Status Serial Cmd: Default:
<Kp status,check digit status,check digit output status,large intercharacter gap,fixed code length status,fixed code length,full ASCII set> Enabled
Options:
Note: This is the only code type enabled by default. 0 = Disabled 1 = Enabled
Check Digit Status (Code 39) Serial Cmd: Default: Options:
<Kp status,check digit status,check digit output,large intercharacter gap,fixed code length status,fixed code length,full ASCII set> Disabled 0 = Disabled 1 = Enabled
Check Digit Output (Code 39) Definition:
Usage: Serial Cmd:
5–Codes
Default: Options:
When enabled, the check digit character is read and compared along with the label data. When disabled, label data is sent without the check digit. Note: With Check Digit Output and an External or Serial trigger option enabled, an invalid check digit calculation will cause a noread message to be transmitted at the end of the read cycle. Check digit Output, added to the bar code symbol, provides additional security. <Kp status,check digit status,check digit output,large intercharacter gap,fixed code length status,fixed code length,full ASCII set> Disabled 0 = Disabled 1 = Enabled
5-8
MS-820 Industrial Bar Code Scanner User’s Manual
Page 77
Chapter 5 Codes
Large Intercharacter Gap (Code 39) Definition: Usage:
Serial Cmd: Default: Options:
When enabled, the scanner can read symbols with gaps between bar code characters that exceed three times (3x) the narrow element width. Large Intercharacter Gap is helpful for reading symbols that are printed out of specification. Caution: Do not use Large Intercharacter Gap with Narrow Margins enabled since a large intercharacter gap (over 3x) could cause a narrow margins (5x) to be interpreted as an intercharacter gap. <Kp status,check digit status,check digit output,large intercharacter gap,fixed code length status,fixed code length,full ASCII set> Disabled 0 = Disabled 1 = Enabled
Fixed Code Length Status (Code 39) Definition: Serial Cmd: Default: Options:
When enabled the scanner will check the label length against the code length field. If disabled any length would be considered a valid label. <Kp status,check digit status,check digit output,large intercharacter gap,fixed code length status,fixed code length,full ASCII set> Disabled 0 = Disabled 1 = Enabled
Fixed Code Length (Code 39) Definition: Usage: Serial Cmd: Default: Options:
Specifies the exact number of characters that the scanner will recognize (this does not include start and stop and check digit characters). The scanner ignores any code not having the specified length. Fixed Code Length helps prevent truncations and increases data integrity by ensuring that only one label length will be accepted. <Kp status,check digit status,check digit output,large intercharacter gap,fixed code length status,fixed code length,full ASCII set> 10 1 to 128
5–Codes
MS-820 Industrial Bar Code Scanner User’s Manual
5-9
Page 78
Code 39
Full ASCII Set (Code 39 Definition:
Usage:
Serial Cmd:
5–Codes
Default: Options:
Standard Code 39 encodes 43 characters; zero through nine, capital “A” through capital “Z”, minus symbol, plus symbol, forward slash, space, decimal point, dollar sign and percent symbol. When Full ASCII Set is enabled, the scanner can read the full ASCII character set, from 0 to 255. Must be enabled when reading characters outside the standard character set (0-9, A-Z, etc.) User must know in advance whether or not to use Full ASCII Set option. Since Full ASCII Set requires two code words to encode one character, it is less efficient. <Kp status,check digit status,check digit output,large intercharacter gap,fixed code length status,fixed code length,full ASCII set> Disabled 0 = Disabled 1 = Enabled
5-10
MS-820 Industrial Bar Code Scanner User’s Manual
Page 79
Chapter 5 Codes
Codabar Definition: Usage:
Codabar is a 16-character set (0 through 9, and the characters $, :, /, ., +, and –) with start/stop codes and at least two distinctly different bar widths. Used in photo-finishing and library applications. Formerly used in some medical applications but not typically used in newer applications.
Codabar Status Serial Cmd: Default: Options:
<Kqstatus,start & stop match,start & stop match output,large intercharacter gap,fixed code length status,fixed code length,check digit type,check digit output> Disabled 0 = Disable 1 = Enabled
Start & Stop Match (Codabar) Definition: Usage: Serial Cmd: Default: Options:
Requires the Codabar start and stop characters (a, b, c, or d) to match before a valid read can occur. Used to increase security of symbology. <Kqstatus,start & stop match,start & stop match output,large intercharacter gap,fixed code length status,fixed code length,check digit type,check digit output> Enabled 0 = Disabled 1 = Enabled
Start & Stop Output (Codabar) Definition: Usage: Serial Cmd: Default: Options:
Causes the start and stop characters to be transmitted with bar code data. Used to verify matching. <Kq status,start & stop match,start & stop match output,large intercharacter gap,fixed code length status,fixed code length,check digit type,check digit output> Enabled 0 = Disabled 1 = Enabled
5–Codes
MS-820 Industrial Bar Code Scanner User’s Manual
5-11
Page 80
Codabar
Large Intercharacter Gap (Codabar) Definition: Usage:
Serial Cmd: Default: Options:
Instructs the scanner to read symbols with gaps between characters exceeding three times the narrow element width. It is helpful for reading symbols that are printed out of specification. Caution: Do not use Large Intercharacter Gap with Narrow Margins enabled since enabling Large Intercharacter Gap (over 3x) could cause a narrow margins (5x) to be interpreted as an intercharacter gap. <Kqstatus,start & stop match,start & stop output match,large intercharacter gap,fixed code length status,fixed fixed code length,check digit type,check digit output> Disabled 0 = Disabled 1 = Enabled
Fixed Code Length Status (Codabar) Definition: Serial Cmd: Default: Options:
When enabled, the scanner will check the label length against the fixed code length field. If disabled any length would be considered a valid label. <Kq status,start & stop match,start & stop match output,large intercharacter gap,fixed code length status,fixed code length,check digit type,check digit output> Disabled 0 = Disabled 1 = Enabled
Fixed Code Length (Codabar) Definition: Usage: Serial Cmd:
5–Codes
Default: Options:
Specifies the exact number of characters that the scanner will recognize (this does not include start and stop and check digit characters). The scanner ignores any code not having the specified length. Fixed Code Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted. <Kq status,start & stop match,start & stop match output,large intercharacter gap,fixed code length status,fixed code length,check digit type,check digit output> 10 1 to 128
Note: Fixed Code Length Status must be enabled for Fixed Code Length to take effect. Note: Because of symbology limitations, setting Code Length to any number less than four will produce undetermined results.
5-12
MS-820 Industrial Bar Code Scanner User’s Manual