Page 211
Glossary of Terms
Appendix P, Glossary of Terms
Bar Code Density. Number of characters per inch or other unit of measure. Baud Rate. The number of discrete signal events per second. Bits per second. Capture. The act of grabbing or recording a frame by an sensor. A frame or succession of frames that are captured. Channel. A high-speed pathway between the computer and the control units of the peripheral devices. Check Digit. A Modulus 43 or Modulus 10 digit that is added to the bar code message for additional data integrity. Command Processing. Allows the user to enter the ESP program from the auxiliary port or send serial string commands from the auxiliary port. Configuration. A setup or process of changing a scanner’s settings to conform to a specific application. Concentrator. Intermediary device that relays data from scanners to a host and commands from the host to the scanner or other devices.
MS-820 Industrial Bar Code Scanner User’s Manual
A-37
Appendices
Active On (ION). An optoisolated input that’s logically “on” when current flows through the connection points. Active Off (IOFF). An optoisolated input that’s logically “on” when no current flows through the connection points. Analog Gain Adjustment (AGC). Adjustment to signal strength that seeks to maintain a constant level regardless of the range of the bar code label. Application Record. A variation of UCC/EAN-128 which adds an application identifier to label data, including user-definable separators, brackets, and padding. Autocalibration. A routine that cycles through various optical settings and selects the combination that produce the best read rate. Autodiscriminate. The ability to decode several different bar code symbologies without changing configuration. Auto Range. Outward focus of the scanner until an object is sensed by signal strength. The scanner then begins searching for a decodable label. Auxiliary Port. RS-232 connections to an auxiliary terminal or device for remote viewing. the transfer of data to and from the host, and under certain conditions a configuration port. Bar Code. The symbol used for recognition by a bar code scanner. An array of parallel bars and spaces of varying widths that conform to recognized standards and can be decoded and displayed as serial data. Bar Code Data. The information that is transmitted from a decoded bar code symbol. Bar Code Label. The physical media on which a bar code symbol is presented.
Page 212
Appendix P Connector. Physical device (plug or socket) on a device or cable to provide in/out connectivity for various circuits and pins. Counter. Memory space provided to keep track of scanner events. Daisy Chain. Linkage of master and slave scanners to allow data to be relayed up to the host via auxiliary port connections. Decode. A good read. The successful scanning and decoding of the information encoded in a bar code label. Default. Restores ROM or Flash settings, initializes serial commands and resets all counters. Delimited. A command or field that is bracketed by pre-defined characters.
Appendices
Decode Rate. The number of good reads per second decoded by the scanner. Depth of Field. The distance between the minimum and maximum range in which a scanner can read bar code labels. Discrete I/O. Inputs and outputs characterized by discrete signal transitions from one voltage level to another so that digital switching can occur. EPROM. Erasable, programmable, read only memory. Embedded Memory. Onboard memory device such as EPROM or flash. End of Read Cycle. The time or condition at which the scanner stops expecting label information to decode. External Edge. Allows a read cycle to be initiated by a trigger signal from an object detector when it detects the appearance of an object (rising edge). The read cycle ends with a good read, a timeout, or a new trigger. External Level. Allows a read cycle to be initiated by a trigger signal from an object detector. The read cycle ends when the object moves out of the detector’s range. Falling Edge. A change of state (to inactive) associated with a level trigger in which the scanner stops searching for bar code symbols. (See Rising Edge.) Fixed Code Length. Increases data integrity by ensuring that only one label length will be accepted. Flash Memory. Memory that can be changed by downloading new code. Focal Length. The distance measured from the scanner to the center of the depth of field, or focal point. Focus. The point at which the tip of the scan beam is at its narrowest. Frame. The total area scanned in an image sensor. Full Duplex. Auxiliary port data is sent directly to the host but not displayed on the auxiliary port screen. Gain. Optimal signal strength. Good Read. A decode. The successful scanning and decoding of the information encoded in a bar code label. Half Duplex. Auxiliary port data is sent directly to the host and displayed on the auxiliary port screen.
A-38
MS-820 Industrial Bar Code Scanner User’s Manual
Page 213
Glossary of Terms Host. A computer, PLC, or other device that is used to execute commands and process data and discrete signals. Host Port. The pins or connections on a scanner or other device that physically connect with a host and - using the RS-232, RS-422, or RS-485 standards - pass data and serial commands from one device to another. Initialize. Implement serial configuration commands into the scanner’s active memory.
MS-820 Industrial Bar Code Scanner User’s Manual
A-39
Appendices
Input. A channel or communications line. Decoded data or a discrete signal that is received by a device. See Output. Intercharacter Delay. The time interval in milliseconds between individual characters transmitted from the scanner to the host. Intercharacter Gap. The extra space between the last element of one character and the first element of the adjacent character of a specific bar code symbol. IrDA. Infrared Data Association which promotes interoperable, infrared data interconnection standards. Label Height. Regardless of orientation, the measurement taken along the length of a label’s individual bars. Label Length. Regardless of orientation, the measurement taken across the label's bars from one end to the other, including the quiet zone. Label Speed (LS) is the distance per second that a label moves as it travels through the scan lines. Label Transitions. The transition of bars and spaces on a label, used to detect the presence of a label on an object. Ladder Label Orientation. A bar code label in which the bars are parallel to the label’s direction of travel. Large Intercharacter Gap. Allows the scanner to read symbols with gaps between bar code characters that exceed three times (3x) the narrow element width. Laser Framing. Setting scan width size by adjusting the on/off duration of the laser beam. Laser On/Off. When enabled, the laser is ON only during the read cycle, provided the scanner is enabled for a Serial or External trigger. LED. Light emitting diode. Longitudinal Redundancy Check (LRC). An error-checking routine that verifies the accuracy of transmissions. Master Scanner. First scanner in a daisy chain mode and linked directly to the host and in tandem to slave scanners. Matchcode. The ability to compare bar code labels being scanned against a master label that is stored in the memory of the scanner. Embedded Menu. Configuration options embedded in the scanner’s erasable memory. ESP-MP Menu. Easy Setup Program - Multiple Platform. Configuration program that runs in Windows-based operating systems 95 and above.
Page 214
Appendix P
Appendices
Mil. One thousandths of an inch or 0.0254 mm. In bar-coding, a measurement standard that identifies a bar code label by the width of its narrowest element. Mismatch. An event that occurs when the scanned bar code label does not match the master label that is stored in the memory of the scanner. Multilabel. A scanner mode which allows a scanner to read more than one bar code label in a single read cycle. Multidrop. A communications protocol for networking two or more scanners or other devices with a concentrator (or controller) and characterized by the use of individual device addresses and the RS-485 standard. Narrow-bar-width. The width of the narrowest bar of a given label, expressed in thousands of an inch (or mils). Narrow Margins. Allows the scanner to read symbols with quiet zones less than 8 times the width of the narrow bar element. Non-delimited. A command that is not bracketed by pre-defined characters. Non-volatile RAM (NOVRAM). Random Access Memory that is available on poweron; that is, after power to the unit has been recycled. Noread. A non-read. A condition that occurs when the scanner is set up to decode labels but no label is scanned during the read cycle. Normally Closed. A discrete output state that is only active when open. Normally Open. A discrete output state that is only active when closed. NOVRAM. Non-volatile random access memory. Data that is saved for “power-on” is saved to NOVRAM. Number of Decodes. The number of times a bar code label is scanned by the scanner during one pass through the laser beam. Object Detector. A photo electric device used to sense the presence or absence of an object (also referred to as a package detector). Output. A channel or communications line. Data or discrete signals that are transmitted or displayed by a device. Output Format. The modification of data output according to a user-defined index of Extraction and Insertion commands. Parity. An error detection routine in which one data bit in each character is set to 1 or 0 (zero) so that the total number of 1 bits in the data field is even or odd. Picket Fence Label Orientation. A bar code label in which the bars are perpendicular to the label’s direction of travel. Pitch. Label (or scanner) rotation around the center of a line perpendicular to the label’s bars. Point-to-Point. A protocol consisting of a single communications event, typically used to connect a bar code scanner to a terminal or host computer. Port. Logical circuit for data entry and exit. (One or more ports may be included within a single connector.)
A-40
MS-820 Industrial Bar Code Scanner User’s Manual
Page 215
Glossary of Terms Protocol. The rules for communication between devices, providing a means to control the orderly flow of information between linked devices. Quiet Zones. Specified “clear” (non printed) areas immediately before and after the bar code symbol. The area is usually white (for black and white bar code) and at least 10 times the width of the narrowest bar, as measured in thousands of an inch. The zones can be other than white as long as their densities remain consistent and they have the required contrast relative to the bars. RAM. (Random Access Memory) Memory that is lost after power is recycled to the unit. Raster. Multiple, stacked scans produced by a separate oscillating mirror or by a spinning mirror with varying facet angles. Read Cycle. A programmed period of time or condition during which the scanner will accept bar code label input. Read Range. The distances in which a label can be reliably read, as measured from the front of the scanner. See “Depth of Field.” Relay. An electrical switch that allows a low power to control a higher one. Reset. Sets all counters to zero.
Scanner. A scanning device that is comprised of a scan head and a decoder integrated in one package. Scan Rate (SR) The number of decodes per second that a given scanner is capable of casting. Scan Width (SW) is the width across the scan beam at a given distance from the scanner in which a label can be read. Send. Transmit data from one device to another. Separator. A character that separates data fields. Serial Commands. Online data strings such as <D> or <P> sent from a host or auxiliary terminal to a scanner or other device. Serial Configuration (Host Configuration). Serial command specifically for changing configuration and distinguished from operational command by the fact that they modify the non-volatile for power up configuration. Skew. Label (or scanner) rotation around the center of the skew axis. Slave Scanner. Linked to the master or preceding scanner in a daisy chain and relays bar code data to the host. See “Daisy Chain.” Specular Reflection Zone. The narrow zone straight out from the scanner in which direct reflected light from a label can distort the scanner’s ability to distinguish bars from spaces. Supplemental. A character or data string that is appended to the main bar code symbol. MS-820 Industrial Bar Code Scanner User’s Manual
A-41
Appendices
Rising Edge. A change of state (to active) that initiates (and in some cases ends) a read cycle with a new trigger, an edge trigger, or the leading edge of a level trigger. (See Falling Edge.) ROM. (Read Only Memory) Memory that cannot be changed.
Page 216
Appendix P Symbol. A bar code. A decodable unit of information that is recognized by a bar code scanner. Symbology. A code type, such as Code 39 or Code 128, with special rules to define the widths and positions of bars and spaces to represent specific numeric or alphanumeric information. Symbology ID. An AIM standard prefix character that identifies the bar code type. Tilt. Label (or scanner) rotation around the centerline of the scan beam. Timeout. A user-selected period of time that ends a scanner's read cycle. Tracking. Adjustment of the precision of analog-to-digital conversion. Transmission. The transfer of data over a communications channel.
Appendices
Transmit. Send or convey signals or information from one device to another. Transparent. Data is passed between the auxiliary port and the host with keyed data echoed to the auxiliary port Trigger. A signal, transition, or character string that initiates a read cycle. Watchdog Timer. A security device that detects system crashes and attempts to reset the scanner. Watchdog Reset. A reset that is forced whenever the software locks up. Wild Card. User-defined character entered into a master label to permit matches with variable characters.
A-42
MS-820 Industrial Bar Code Scanner User’s Manual