The text of a manual · part 2 of 15
MS-810 Industrial Scanner User's Manual, pages 11 to 20
Pages 11 to 20 of 144
The original document is the PDF (2.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-810
Page 11
1
Quick Start
Chapter Contents Step 1 - Plan Scanning System .............................................................. 1-2 Step 2 - Attach Cabling ........................................................................... 1-3 Step 3 - Consider Read Range and Scan Width .................................... 1-4 Step 4 - Position Scanner ....................................................................... 1-5 Step 5 - Mount Scanner .......................................................................... 1-6 Step 6 - Establish Communications ........................................................ 1-7 Step 7 - Configure Scanner .................................................................... 1-8 Step 8 - Test Decode Rate with Static Label .......................................... 1-9 Step 9 - Test Decode Rate with Moving Label ..................................... 1-10 Step 10 - Increase the Number of Scans ............................................. 1-11
This chapter provides step-by-step instructions for setting up and installing the MS-810 scanner. Note: Bar code labels should meet minimum ANSI (American National Standards Institute) standards as specified in ANSI Bar Code Print Quality Guideline, X3.1821990.
MS-810 Industrial Scanner User’s Manual
1-1
1–Quick Start
Chapter
Page 12
1–Quick Start
Chapter 1
Step 1
Plan Scanning System
Before installing the MS-810 scanner you should sketch out a diagram of your scanning system, showing equipment, connector and cable types, and cable lengths. (For wiring information, see “Attach Cabling” on page 1-3.) Figure 1-1 shows a typical scanning system setup.
2 outputs from internal relays
Bar-coded item flow External Object Detector
MS-810 Scanner
Host
To power supply
Figure 1-1 Typical Setup
1-2
MS-810 Industrial Scanner User’s Manual
Page 13
Attach Cabling
The MS-810 has a 15-pin connector. RS-232 cabling from the 15-pin connector to the host can be up to 47 feet provided it does not include DC input.
Scanner
Host
Transmit 2
2 Transmit
Receive 3
3
Signal Ground
Receive Signal Ground
4
Figure 1-2 DTE Host Connection
6
11
1
5
10
15
Figure 1-3 MS-810 15-pin Connector
Note: Pinouts are shown in Appendix B, “Electrical Specifications” on page A-4 and in “Special 5 VDC MS-810” on page A-21.
MS-810 Industrial Scanner User’s Manual
1-3
1–Quick Start
Step 2
Page 14
1–Quick Start
Chapter 1
Step 3
Consider Read Range and Scan Width a) Verify that the labels to be scanned will pass through the readable range. Optimum decode rates can be expected at the center of the depth of field (halfway between minimum and maximum read range) for a given bar code density. b) Note the approximate scan width at the specific distance the labels will be passing through. Read range is the distance from the scanner in which a passing label can be read. For the MS-810, read range varies from 2 to 30 inches depending on label density and optical version of scanner. Scan width is that distance across the scan arc in which a label can be read. For a moving label, the closer to the scanner, the shorter the time it will be within the scan width, and hence the fewer scans it will receive.
Figure 1-4 Read Range and Width
Note: See Table A-1, “Range Data,” on page A-3.
1-4
MS-810 Industrial Scanner User’s Manual
Page 15
Position Scanner a) Position the scanner in a place devoid of sunlight, bright lights, or laser light from other sources. b) Avoid excessive tilt, skew, or pitch. Maximum tilt is determined by label characteristics and the number of scans required. Maximum skew is ±40°; maximum pitch is ±50°.1 c) Pitch label slightly to avoid specular reflection, the return of direct, non-diffused light. For the MS-810 raster scanner, specular reflection is avoided by pitching labels at least 5° plus or minus from a line perpendicular to the mirror. 2
Figure 1-5 Tilt, Skew, and Pitch Axes
Note: Another way to avoid specular reflection is to skew the scanner slightly in relation to the label.
1. Maximum tilt is determined by label characteristics and number of scans required. 2. The specular reflection zone is a narrow zone straight out from the scanner in which direct reflected light from a label can distort the scanner’s ability to distinguish bars from spaces. MS-810 Industrial Scanner User’s Manual
1-5
1–Quick Start
Step 4
Page 16
1–Quick Start
Chapter 1
Step 5
Mount Scanner
The MS-810 scanner can be top or bottom mounted depending on your model type. Use the measurements provided in figure 1-6 to locate centers of mounting holes and drill as specified: Top mount – drill two 0.16 inch (4.06 mm) diameter holes. Bottom mount – drill two 0.203 inch (5.16 mm) diameter holes.
Figure 1-6 MS-810 Mounting Dimensions
Caution: Maximum penetration depth of screws is 0.29 inch (7.37 mm) for top mount or 0.15 inch (3.81 mm) for bottom mount. Caution: To prevent twisting or distortion of the scanner housing, ensure that the mounting surface or bracket is flat.
1-6
MS-810 Industrial Scanner User’s Manual
Page 17
Establish Communications
1–Quick Start
Step 6
To set up the host communications, from the ESP™ main menu: a) Select Serial Port and Configure from the pull-down menus. b) Make the port selection from Serial Port options COM 1 through COM 8. (Usually COM 2 for desktops and COM 1 for laptops.) c) Click the Auto Baud button down menu.
or select Auto Baud from Serial Port pull
ESP will cycle through the various baud, etc. combinations until communications are established (look for the CONNECTED banner on your screen) or the cycle is completed without connecting and a DISCONNECTED banner appears on your screen. You can also interrupt the search by clicking the Stop button. Allow some time for the auto baud routine to test most of the combinations. You can watch this at the bottom of the dialog box. Once it has found it, it will change the host’s settings to match the scanner’s. The default settings for the MS-810 scanner are 9600 baud, Even Parity, 7 Data Bits, and 1 Stop Bits.
MS-810 Industrial Scanner User’s Manual
1-7
Page 18
1–Quick Start
Chapter 1
Step 7
Configure Scanner
You can make changes from the default settings by modifying individual ESP menus and saving those changes to the scanner. For explanations of menu configuration settings, see Chapter 2, “ESP Menu Configuration.” Note: When you save communications changes to the scanner, serial port settings are automatically matched. Note: You can check the scanner’s settings at any time by clicking SEND/RECV and RECEIVE FROM SCANNER to receive the scanner’s current settings into ESP. As data is being received a blue bar will fill across the bottom of the dialog box.
1-8
MS-810 Industrial Scanner User’s Manual
Page 19
Test Decode Rate with Static Label a) Position the label in front of a functioning scanner, click on the Utilities button, and in the Read Rate dialog either click the Percent or Decodes/Sec radio button and click Start, or enter the <Cp> or <C> command from the host terminal to launch test. b) Observe rate. (The percent or decode rate is added to the front of the data string.) c) End the test by clicking the Stop button or the <J> command. Note: If, after making adjustments, you have changed the read range or another parameter used in the number of scans formula, you should recalculate the number of scans (see “Number of Scans” on page A-18). Note: Variations between labels are common. For this reason, the greater number of sample labels you test, the more likely you are to achieve optimum decode rates.
MS-810 Industrial Scanner User’s Manual
1-9
1–Quick Start
Step 8
Page 20
1–Quick Start
Chapter 1
Step 9
Test Decode Rate with Moving Label
Once you’ve mounted the scanner and established a good read rate with a stationary label, you can repeat the test with a moving label. To ensure reliable scanning, you need to apply a minimum of five scans to each label. This means that all variables, label speed, read range, etc. are significant. To calculate in advance the number of scans that the label will receive, use the formulas described in Appendix G, “Number of Scans,” on page A-18.
1-10
MS-810 Industrial Scanner User’s Manual