Page 121
Using the IB-105 Table A-6 IB-105 Trigger Connector
Table A-9 IB-105 D-sub Host Connector
Pin
Function
Pin
1
Trigger in to pin 9 of scanner connector
1
Chassis ground
2
Relay contact normally open (up to 1watt)
2
Host RS-232 TXD (RS-232)
3
VCC (+5V)
3
Host RS-232 RXD (RS-232)
4
VBB (+12V, if using Microscan’s standard object detectora)
4
5
Ground
Host RS-232 RTS or under software control aux RS-232 TXD, or RS-485 transmitter enable (out)
6
Relay common
5
Host RS-232 CTS or under software control aux RS-232 RXD (in)
6
Relay-2 output from pin 14 of scanner connector.
a. P/N 99-440001-03
Table A-7 IB-105 Scanner Connector Pin
Function
Function
7
Signal ground Relay-1 output from pin 7 of scanner connector.
1
+5 VDC (in)
8
2
Transmit data (RS-232) (out)
9
VCC (+5V)
3
Receive data (RS-232) (in)
4
Signal ground (RS-232)
10
Trigger input; same as pin 1 of trigger connector
5
NC
Default configuration pin goes to pin 8 of the scanner connector and the default switch
6
RTS (5V only)
11
7
Relay-1 Driver (out). Can sink 10 mA and source 2 mA.a
12
NC
13
Host RS-422/RS-485 (+in)
8
Default configuration (in)
9
Trigger (in) from 3V to 24V
14
Host RS-422/RS-485 (–out)
10
CTS (5V only)
15
11
NC
Relay contact normally open (up to 1watt) (common with pin 17)
12
New master (in)
16
Host RS-422/RS-485 (–in)
Relay contact normally open (up to 1watt) (common with pin 15)
13
Chassis ground
17
14
Relay-2 Driver (out). Can sink 10 mA and source 2 mA
18
NC
19
Host RS-422/RS-485 (+out)
20
NC
21
NC
15
NC a. Relay-1 output also causes closure of an isolated relay between pin 15 and pin 17 of the IB-105 host connector.
Table A-8 IB-105 Power Connector Pin
Function Signal ground
2
Chassis ground
3
+5 VDC
4
NC
5
NC
Ground
23
NC
24
NC
25
New master input to pin 12 of the scanner connector and new master button
Appendices
1
22
MS-810 Industrial Scanner User’s Manual
A-23
Page 122
Chapter A Table A-10 IB-105 LAN (RJ11) Connector Pin
Function
1
Chassis ground
2
RS-422/485 (+in)
3
RS-422/485 (–in)
4
RS-422/485 (+out)
5
RS-422/485 (–out)
6
Chassis ground
Table A-11 IB-105 Options P/N 99-420001-XX
Description
–01
RS-232 with RTS/CTS or RS-485
–02
RS-232 with RTS/CTS or RS-422
–03
RS-422 with Aux RS-232 or RS-232
–04
RS-422 (MS-810) to RS-232
–05
RS-422 LAN to RS-232 converter
Internal Dip Switches 8 7 6 5 4 3 2 1
= ON
= OFF
The IB-105 routes signals between the scanner and other devices. It has the following connectors and switches: New Master Switch
Used in match code operations to indicate that the next label will be read as the new master label. Momentarily press the switch to activate it. Trigger Connector
Connects to an object detector. Internal Relay
The IB-105 uses the scanner’s relay-1 signal to drive a one watt internal relay that connects pin 2 with pin 6 on the trigger connector and pin 15 with pin 17 on the host connector. The relay contacts are closed when relay-1 (pin 7 of the scanner connector) is high. (See tables A-6, A-7, A-8, and A-9 for pinouts.)
Appendices
These contacts are isolated from ground to prevent unwanted ground currents. Default Switch
Provides a convenient way to restore factory configuration settings to the scanner. This switch is recessed to prevent accidentally defaulting the scanner. For default instructions, see “Transferring/Restoring Files” on page A-11.
A-24
MS-810 Industrial Scanner User’s Manual
Page 123
Using the IB-105 Power Switch
Connects the +5V supply (pin 3 of power connector) to the IB-105. Power Connector
Designed to accept the standard +5V Microscan power supply. Chassis ground must be properly connected for the IB-105 and scanner to pass all regulatory requirements (FCC, CE, CISPER-22). Mode Switch
Used in options -01 and -02 to toggle the host port between RS-232 and RS-485 or between RS-232 and RS-422, respectively. Options -03 and -04 require that the Mode switch be pushed IN for proper operation. 25-pin (host) Connector
The 25-pin (host) connector is similar to the MS-3000 host connector; therefore, applications that were set up for the MS-3000 will work with the IB-105. The only exception is the addition of relay contact pins 15 and 17 of the 25-pin host connector that are in parallel with pins 2 and 6 of the trigger connector. Internally the IB-105 adds RS-232 levels to the RTS and CTS signals on the 25-pin (host) connector. These pins are alternately used for the second RS-232 port depending on the scanner’s configuration. RS-485/422 (LAN) Connector
The RS-485/422 (LAN) connector is pinned out the same as the MS-3000 to make it compatible with the Microscan network. See table A-10 on page A-31 for pinouts.
OPTION -01: RS-232 with RTS/CTS to RS-485 or Second RS-232 Serial Port Use the Mode switch to toggle the host port between RS-232 and RS-485. • When the Mode switch is OUT the RS-232 signals go through to the 25-pin (host) connector. Scanner
RS-232
IB-105
RS-232
Host
• When this switch is IN the IB-105 takes RS-232 signals (TXD, pin 2, RXD, pin 3) and converts them to RS-485 levels. The RS-485 levels are present at both the RS-485/422 (LAN) connector and the 25-pin (host) connector. (See tables A-6, A-7, A-8, and A-9 for pinouts.)
RS-232
RS-485
Host
RS-485
LAN
Appendices
Scanner
IB-105
Note: In this mode the scanner must be set up for Multidrop communications. MS-810 Industrial Scanner User’s Manual
A-25
Page 124
Chapter A Note: The second RS-232 TXD pin (pin 4 of the host connector) is not available in this mode.
OPTION -02: RS-232/422 with RTS/CTS or Second RS-232 Serial Port Use the Mode switch to toggle the host port between RS-232 and RS-422. When the Mode switch is OUT, the RS-232 signals go through to the 25-pin (host) connector. Note: The second RS-232 TXD pin is available in this mode. Scanner
RS-232
IB-105
RS-232
Host
• When the Mode switch is IN, the IB-105 takes RS-232 signals (TXD, RXD) and converts them to RS-422 levels. The RS-422 levels are present at both the RS-485/422 (LAN) connector and the 25-pin RS-232 connector. See page A-30 and page A-31 for pinouts.
Scanner
RS-232
RS-422
Host
RS-422
LAN
IB-105
OPTION -03:RS-422 with Second RS-232 Serial Port on Pins 2 and 3 In this configuration the Mode switch must be IN for proper operation. This mode is the same as option -02 except that the second serial port (aux) is present on pins 2 and 3 of the 25-pin (host) connector. This allows a standard RS-232 cable to connect to the second serial port.
Scanner
RS-232
RS-232
Aux
RS-422
LAN
IB-105
OPTION -04:RS-422 (MS-810) to RS-232
Appendices
In this configuration the Mode switch must be IN for proper operation. This configuration has the same features as the previous configurations except that the Scanner connector pins for TXD, RXD, CTS, RTS are used by the MS-810 for 422 communications. So to connect an RS-232 terminal to the MS-810, the IB-105 converts these signals to RS-232 levels and back. Pins 2 and 3 on the 25-pin (host) connector are the only communications pins that are active in this configuration. Scanner
A-26
RS-422
IB-105
RS-232
Host
MS-810 Industrial Scanner User’s Manual
Page 125
Using the IB-105 OPTION -05: RS-422 LAN to RS-232 Terminal 1 In this configuration the Mode switch must be IN for proper operation. This is a special configuration to convert RS-422 signals back to RS-232. The main purpose for this configuration is to use two IB-105’s, one to convert the scanner communications to RS-422 and one to convert these signals back to RS-232 (this configuration) for long distance communications (up to 4000 feet).
Scanner
IB-105
RS-232
(-02 or -04)
RS-422
IB-105
RS-232
Host
(-05)
See “IB-105 D-sub Host Connector” on page A-23 and “IB-105 LAN (RJ11) Connector” on page A-24 for pinouts. The LAN cable pinout must be as follows: LAN RJ-12 cable #1 IB-105 RS-485/422 Connector
#2 IB-105 RS-485/422 Host Connector
1
1
2
2
3
3
4
4
5
5
The signal routing is from the LAN connector to the LAN connector. The scanner and trigger connector are not used in this configuration.
MS-810 Industrial Scanner User’s Manual
A-27
Appendices
1. Access to the configuration menus of a scanner that is in a polled mode can be forced (without defaulting) by sending the <D> command from an auxiliary terminal via the auxiliary RS-232 port.
Page 126
Chapter A
Appendix J, Troubleshooting Operational Tips Do: • Check inputs (label speed, length, height, etc.) to ensure the desired number of scans per label. • Avoid excessive tilt, pitch, and skew of the bar code label. • Check the label for readability by doing a decode rate test. If there is any question about the label's readability, contact your Microscan representative. • After changing any parameter that might affect decode rate, repeat decode rate test. • Clean the scanner window with a clean, dry Q-tip or cotton cloth on a regular basis. Do Not: • Aim the scanner into direct light or sunlight. • Aim the scanner into an external object detector or other light-emitting device. • Obstruct the scanner window with mounting hardware or other objects. • Connect chassis of scanner and host to different ground potentials. • Operate the scanner in excessive temperature environments. The MS-810 scanner when used correctly should produce good reads. If not, table A-12 lists some of the more common problems associated with setting up and using the scanner. If you are unable to locate or correct the problem, call your Microscan representative.
WARNING
Appendices
Do not look directly into laser aperture. Laser light can be hazardous to your eyes.
A-28
MS-810 Industrial Scanner User’s Manual
Page 127
Troubleshooting
Problem
Possible Cause
Getting an “Upload from Scanner has timed out!” message when clicking the Receive from Scanner command.
Host cable defective or not wired properly
Check cable connections and wiring. (See “Attach Cabling” on page 1-3.)
Solution
Scanner configuration settings do not match host's
Reset scanner to default and/or match host settings with scanner's.
Wrong label type (different label type being scanned than that enabled in firmware)
Check label configuration settings to be certain that they match the label type being scanned. If label type is in doubt, enable Autodiscriminate All Codes (<P> command). Ensure that fixed length and check sums, if enabled, are set correctly.
Incorrect label range or label See “Consider Read Range and Scan too long to be totally covered Width” on page 1-4. Reposition label and by scan beam. check the decode rate.
No data or decode rate in decode rate Poor label quality Try a label that is known to be readable. test (<C>) Excessive ambient light, sun- Shield the bar code and/or scan head to verify light, or strobes that excessive light is not the problem.
Low decode rates during decode rate test (<C>)
Object detector or another scanner interfering with reads
Remedy by remounting, eliminating interference, or shielding. Many object detectors emit pulsed infrared signals that can seriously degrade the decode rate if they shine into the scanner or onto the bar code label when it is being read.
Poor label, range, placement, etc.
See “No data...” in previous Problem heading. Do “Increase the Number of Scans” on page 1-11.
Object detector not positioned properly
Ensure read cycle is active during the time the label is in the scan line.
End of Read Cycle not properly defined
Ensure that the proper End of Read Cycle is defined in scanner configuration.
Scanner not triggered when in external mode
Ensure trigger device is operating properly. Do Decode Rate Test <C>. If it reads successfully, the problem is triggering.
Decode rate okay but not getting any output (including Scanner not triggered when noreads) in trigin serial mode gered mode
Ensure the label is not excessively skewed, tilted, or otherwise disoriented. Ensure the bar code is in the scan line when it is supposed to be. Ensure that the bar code is pitched or skewed slightly so as to avoid specular reflection.
MS-810 Industrial Scanner User’s Manual
A-29
Appendices
Label misaligned or reflecting direct laser light
Ensure that correct serial trigger character is entered with start/stop characters (a left angle bracket < (unless redefined) and a right angle bracket >).
Page 128
Chapter A Problem
Possible Cause Triggering/timeout out of sync
Decode rate okay but getting only Object detector or another noread messages in scanner interfering with triggered mode reads Window dirty or obstructed
Solution Review triggering and timing. (See the “Operation Menu” on page 2-16.) Remedy by remounting, eliminating interference, or shielding. Many object detectors emit pulsed infrared signals that can seriously degrade the decode rate if they shine into the scanner or onto the bar code label when it is being read. Clean or remove obstruction.
Previous label Scanner configured in Conread, but subsetinuous Read 1 Output quent label will not Scanner in polled mode read
Scan a label that contains different data than that of the one being read.
Proper trigger levels not Scanner not enter- enabled ing read cycle in Trigger circuit not correctly triggered mode wired (trigger not working) Object detector inoperative
Ensure that the trigger pulse and the trigger polarity settings are correct.
Check communications protocol.
Ensure that the trigger circuit wiring meets the scanner requirements. (See“Attach Cabling” on page 1-3.)
Appendices
Check detector range and sensitivity. Try a detector that is known to be good.
A-30
MS-810 Industrial Scanner User’s Manual
Page 129
Bar Code Symbology
Appendix K, Bar Code Symbology Before choosing a bar code symbol, consider:1 • the type of information to be scanned (numeric only, alphanumeric) • the length of the messages to be encoded • how and where labels are to be applied • label printer capabilities
• scan speed • beam width • the space available on the object to be identified • host software limitations • range of the scanner • the speed of the conveyor
Microscan standard scanner firmware supports the following five bar code symbologies. (Firmware can also be custom ordered to support other symbologies.) Code 39. An alphanumeric code with unique start/stop code patterns, composed of nine black and white elements per character, three of which are always wide. Considered the de facto standard for non-retail symbology. Codabar. A 16-character set (0 through 9, and the characters $, :, /, ., +, and –) with start/stop codes and at least two distinctly different bar widths. It is commonly used in libraries, photo finishing, and air parcel express applications. (A check digit is highly recommended.) I 2 of 5. Interleaved 2 of 5 is a high-density, continuous numeric symbology used mainly in the distribution industry. I 2 of 5 encodes two digits: one in the bars, and one in the spaces. (A check digit is highly recommended.) UPC and EAN. UPC (Universal Product Code) is a fixed length numeric, continuous symbology used in the supermarket and retail industry. The European Article Numbering (EAN) system is a well-known variation of UPC. Both UPC and EAN can have two or five digit supplemental bar code data following the normal code. Code 128. A very high density alphanumeric symbology. Will encode all 128 ASCII characters, it is continuous, has variable length, and uses multiple element widths measured edge to edge. It is widely used in the non-food distribution industry and shipping containers.
Appendices
1. For further information about symbology, see The Bar Code Book, by Roger C. Palmer, Helmers Publishing, Inc., 1989. MS-810 Industrial Scanner User’s Manual
A-31
Page 130
Chapter A
Appendix L, Interface Standards Interface Standards, established by the Electronic Industries Association (EIA), specify such things as the signaling voltage levels, maximum cable lengths, and number of drivers. With Microscan devices, selection of interface is made by pin assignment and, in the case of the host communications, by software switching between RS-232 and RS-422. Microscan devices use RS-232, RS-422, and RS-485 multidrop.
RS-232 RS-232 defines an interface between two devices such as, for example, the scanner and host. It differs from the other interfaces by dedicating individual pins to specific functions and by requiring both devices to share a common ground line. Since both device chassis are connected to a common ground, a ground loop potential and the possibility of noise interference exists. Therefore cable lengths are limited to a maximum of 50 feet (19.7m). Despite being the most limited, this interface is used frequently because of the large installed base of RS-232 equipment.
RS-422 RS-422, unlike RS-232, measures signals deferentially; that is, the receiver looks at the potentials between the two receive (or transmit) wires rather than the potential between signal and ground. As a result, cables, if shielded, can be up to 4000 feet (1219m) in length. Like RS-232, RS-422 communication is designed for only two devices on a single line and must have a common ground. It can be used wherever RS-232 is used.
RS-485
Appendices
RS-485, like RS-422, can transmit up to 4000 feet (1219m) using differential voltages but unlike RS-422, its transmitters are turned off until a request for data is received from the host. RS-485 is used exclusively in Multidrop protocol.
A-32
MS-810 Industrial Scanner User’s Manual