Page 41

Operation Menu label is in the read range of the scanner. When To Output options have no affect on Continuous Read. Continuous Read is useful in testing label or scanner functions.

Continuous Read 1 Output Note: Enabling Continuous Read 1 Output when Number of Labels (page 2-21) is set to any number greater than one will cause Number of Labels to default back to one.

With Timeout disabled (that is, End Of Read Cycle set to New Trigger), the scanner will output the current label data immediately, but output it only once. A new label appearing at any time in the scan range will produce a new read output as long as the new label is not identical to the previous label.

External Level1 Allows a read cycle to be initiated by a trigger signal from an object detector when an object appears within the detector’s range. The read cycle exists as long as the detector “sees” the object and does not end until the object moves out of the detector’s range even if a good read or timeout occur sooner (figure 2-5).

Figure 2-5 External Level Trigger Signals

1. Level and Edge apply to the active logic state (positive or negative) that exists while the object is in a read cycle, between the rising edge and falling edge. Rising edge is the trigger signal associated with the appearance of an object. Falling edge is the trigger signal associated with the subsequent disappearance of the object. MS-710 Scanner User’s Manual

2-17

2–Menu Config.

Label data is immediately transmitted once every time new label data is placed in front of the scanner. With Timeout enabled for End Of Read Cycle, if the label doesn't change, the scanner will repeat the output at the end of each subsequent timeout period. For example, if Timeout were set to one second, the scanner would output the label data immediately, and then repeat the output at intervals of one second, for as long as the label continued to be scanned.

Page 42

Chapter 2 External Edge As with Level, Edge allows a read cycle to be initiated by a trigger signal from an object detector when it detects the appearance of an object (rising edge). But unlike Level mode, the removal of an object (falling edge) does not end the read cycle. With Edge enabled, the read cycle ends with a good read output, a timeout, or a new trigger (figure 2-6 on page 2-18).

1

2–Menu Config.

2

Initiate Read Cycle: Object # 1, moving in front of the detector beam, causes a trigger signal to be sent to the scanner, initiating the read cycle.

Active

0 associated waveforms (assumes Trigger Pulse set to Positive)

Object detector

2

Initiate Second Read Cycle Object # 2, moving in front of the detector beam, causes another trigger signal to be sent to the scanner. This signal initiates a new read cycle and ends the previous read cycle (unless a New Trigger is enabled and a good read or timeout has not already occurred).

1

Object detector

Active 0

Figure 2-6 External Edge Trigger Signals

Serial Data The scanner accepts an ASCII character from the host or controlling device as a trigger to start a read cycle. Serial data trigger behaves the same as External Edge.

Serial Data & External Edge The scanner accepts either an external trigger or a serial ASCII command to start a read cycle.

End of Read Cycle Default:

Timeout

Options:

Timeout, New Trigger, Timeout & New Trigger

Allows you to choose the circumstances that will end the read cycle. The read cycle is the time during which the scanner will receive and process label data. When the Triggering Mode option is set in an External or Serial mode of operation, the trigger event initiates the read cycle. Note: When operating in Continuous Read or Continuous Read 1 Output, the scanner is always in the read cycle.

2-18

MS-710 Scanner User’s Manual

Page 43

Operation Menu Timeout Can end the read cycle after a specified period of time, and if no label has been read, causes a noread message, if enabled, to be transmitted. With either External Edge, Serial Data, or Serial Data & Edge enabled, a timeout ends the read cycle. With External Level enabled, the read cycle does not end until the falling edge trigger occurs, and the next read cycle does not begin until the next rising edge trigger.

New Trigger Ends the read cycle at the occurrence of a new trigger event, and if no label has been read, causes a noread message, if enabled, to be transmitted at the occurrence of the new trigger event. With either External Edge, Serial Data, or Serial Data & Edge enabled, and edge or serial trigger ends a read cycle and initiates the next read cycle. With External Level enabled, a falling edge trigger ends a read cycle, However, the next read cycle does not begin until the occurrence of the next rising edge trigger.

Timeout & New Trigger Ends the read cycle after a specified period of time or at the occurrence of a new trigger event, and if no label has been read, causes a noread message, if enabled, to be transmitted. With either External Edge, Serial Data, or Serial Data & Edge enabled, a timeout, or an edge or serial trigger, whichever comes first, ends the read cycle. With External Level enabled, the read cycle does not end until the occurrence of a falling edge, and the next read cycle does not begin until the next rising edge trigger.

Timeout (in 10 ms incs) Default:

100 (one second). Corresponds to 1000 ms displayed in the menu.

Options:

0 to 65535. Divide the number to be entered by 100 for time in seconds.

Note: Timeout or Timeout & New Trigger under End of Read Cycle (page 2-19) must be enabled for Timeout (in 10 ms incs) to take effect. Allows you to define the duration of the timeout period.

MS-710 Scanner User’s Manual

2-19

2–Menu Config.

With Continuous Read 1 Output enabled, a timeout initiates a new read cycle and allows the same label to be read again.

Page 44

Chapter 2 Serial Trigger Character Default:

^]. Corresponds to <GS> displayed in the menu.

Options:

Any single ASCII character, including control characters, except NUL (00H), an existing host command character,1 or an on-line protocol character.

2–Menu Config.

Note: Serial Data (page 2-18) or Serial Data & Edge (page 2-18) must be enabled for Serial Trigger Character to take effect. “N/A” is displayed in the menu when all other triggering modes are enabled. Allows you to define a single ASCII character as the host serial trigger character that initiates the read cycle. The serial trigger is considered an on-line host command and requires the same command format as all host commands (that is, to be entered within the < > brackets).

External Trigger Polarity Default:

Positive

Options:

Positive, Negative

Note: External Level (page 2-17), External Edge (page 2-18), or Serial Data & Edge (page 2-18) must be enabled for External Trigger Level to take effect. “N/A” is displayed in the menu when all other triggering modes are enabled. Allows you to determine whether a positive or negative transition will initiate the read cycle. Note: If using the Microscan object detector (P/N 99-440001-03), use positive trigger polarity.

Trigger Filter Default:

78 (approximately 10 ms). Corresponds to 9984 µs displayed in the menu.

Options:

2 to 255 (approximately 0.256 ms to 32 ms in 0.128 ms increments). Multiply the number to be entered by 128 for time in microseconds, then divide by 1000 for time in milliseconds.

Allows you to set a trigger bounce filter duration.

1. For example, assigning an upper case D would nullify the <D> (Enter Menu Configuration) command. For a list of operational commands used by the scanner, see Chapter 4, “Operational Commands.”

2-20

MS-710 Scanner User’s Manual

Page 45

Operation Menu Good Decode Reads Default:

1

Options:

1 to 31

Allows you to select the number of good reads (from 1 to 31) required per label before a good decode output. Note: Be sure to set the value within the determined scan rate for the scanning setup so that the scanner is capable of scanning a label the required number of times.

Default:

Disabled

Options:

Disabled, Enabled

Note: Match Code Type (page 2-22) and a triggered mode (page 2-16) must be set for Enabled or Sequential for New Master Pin to take effect. Allows you to momentarily connect pin 12 to ground in order to clear any existing master label information from memory and allows the next label to be read as the new master label information.

Number of Labels Default:

1

Options:

1 to 6

Note: If Number of Labels is set to any number greater than one while Match Code Type or Continuous Read 1 Output is enabled, Number of Labels will default back to one. Note: If using Supplementals option for UPC, see “Supplementals,” on page 2-29 for specific directions on defining Number of Labels. Allows you to choose the number of different labels that can be read in a single trigger event. The following conditions apply: 1. Each label must be different to be read. 2. The maximum number of characters in any one label is 64. 3. The maximum number of characters in a single scan line is 384. 4. The maximum number of characters for all labels is 384, including preamble, postamble, and all spaces and commas. 5. All noread messages are posted at the end of the data string. 6. If more than one label is within the scan beam at the same time, label data may not be displayed in the order of appearance.

MS-710 Scanner User’s Manual

2-21

2–Menu Config.

New Master Pin

Page 46

Chapter 2 Multilabel Separator Default:

, (comma)

Options:

Any available ASCII character, except NUL.

Allows you to choose the separator character to be inserted between each label. Note: UPC separator character, if used, must be different than the multilabel separator.

2–Menu Config.

Match Code Type

Figure 2-7 Match Code Type Default:

Disabled

Options:

Disabled, Enabled, Wild Card, and Sequential

When not disabled, allows you to enter a master label into the scanner's RAM to be compared with subsequently scanned labels. The results of this comparison determine the scanner’s data and relay outputs, if enabled. The following conditions apply: 1. A triggered mode (page 2-16 to page 2-18) must be enabled for Match Code Type to take effect. 2. Not disabling Match Code Type when Number of Labels is set to any number greater than one will cause Number of Labels to default back to one. 3. If you wish to send a pulse on a Good Read, Match Code Type must be disabled (see “Output On” on page 2-33).

Disabled Disabled has no effect on operations.

Enabled Instructs the scanner to compare labels or portions of labels with the master label.

2-22

MS-710 Scanner User’s Manual

Page 47

Operation Menu Sequential Instructs the scanner to compare labels or portions of labels for sequential numbers in ascending or descending order. There are four ways to load a master (see “Master Label Entry” on page 2-24). In every case sequencing occurs after each match. See “Match Code Type” on page 3-11 for special noread and mismatch sequences.

Wild Card Allows you to enter user defined wild card characters in the master label.

As in the above example, when wild cards are appended to the end of the master label, labels of variable lengths can result in matches. However, wild cards in the beginning or center of a label (e.g., UR**NT) do not allow for variable label lengths.

Matchcode Master Default:

(blank)

Options:

Displays current master and accepts user entry up to 64 characters.

Allows you to edit an existing master or type in a new master label from your keyboard.

Sequential Matching Default:

Increment

Options:

Increment, Decrement

Defines the order (ascending or descending) in which labels will be compared when Match Code Type is set to Sequential.

Match Start Position Default:

0

Options:

0 to 64

Match Start Position must be set to 1 or greater to enable this feature. Defines the first character in the label (from left to right) that will be compared with those of the master label when Match Code Type is set to Enabled or Sequential. For example, if you set Match Start Position to 3, the first 2 characters read in the label will be ignored and only the 3rd and subsequent characters to the right will be compared, up to the number of characters specified by Match Length.

MS-710 Scanner User’s Manual

2-23

2–Menu Config.

For example, with wild card defined as the default asterisk, entering URGENT** as your master label will result in matches for URGENT, URGENT1, and URGENT12 but not for URGENT123.

Page 48

Chapter 2 Match Length Default:

1

Options:

1 to 31

2–Menu Config.

Defines the length of the character string that will be compared with that of the master label when Match Code Type is set to Enabled or Sequential and Match Start position is set to 1 or greater. For example, If Match Length is set to 6 in a 10 character label, and Match Start Position is set for 2, only the 2nd through 7th characters (from left to right) will be compared.

Wild Card Character Default:

* (asterisk)

Options: Any ASCII character Allows you to define the wild card character that can be used when defining a master label. Master Label Entry With Match Code Type set to Enabled, Sequential, or Wild Card, a master label can be entered in four ways: 1. By typing in master label data in the Utilities menu. 2. With New Master Pin enabled (see page 2-21), toggling scanner pin 12 to ground (or by momentarily pressing the New Master button on the IB-105) will save the next label read as the master label. 3. Sending serial command <G> allows the next label read to be the master label. 4. Sending a serial command in the format <)XXXX)> downloads data as the master label.

2-24

MS-710 Scanner User’s Manual

Page 49

Code Type Menu

Code Type Menu

2–Menu Config.

Figure 2-8 Code Types Menu Structure

Default Clicking the DEFAULT button will reset all parameters on the current menu to defaults. This does not take effect until it is saved to the scanner with the SEND/NO SAVE or SEND/SAVE buttons.

Code 39 Default:

Enabled

Options:

Enabled, Disabled

Check Digit Default:

Disabled

Options:

Disabled, Enabled

Code 39 is self-checking and does not normally require a check digit. However, for additional data integrity, a Modulus 43 check digit can be added to the bar code message. With Check Digit and an External or Serial trigger option enabled (see “Triggering Mode” on page 2-16), an invalid check digit calculation will cause a noread message to be transmitted at the end of the read cycle. MS-710 Scanner User’s Manual

2-25

Page 50

Chapter 2 Check Digit Output Default:

Disabled

Options:

Disabled, Enabled

When enabled, the check digit character is sent along with the label data. When disabled, label data is sent without the check digit.

2–Menu Config.

Large Intercharacter Gap Default:

Disabled

Options:

Disabled, Enabled

Allows the scanner to read labels with gaps between bar code characters exceeding three times the narrow element width.

Fixed Code Length Default:

Disabled

Options:

Disabled, Enabled

Used to increase data integrity by ensuring that only one label length will be accepted.

Code Length Default:

10

Options:

1 to 64

Note: Fixed Code Length must be enabled for Code Length to take effect. Allows you to specify the exact number of characters that the scanner will recognize (this does not include start and stop). The scanner will ignore any code not having the specified length.

Codabar Default:

Disabled

Options:

Disabled, Enabled

Start & Stop Match Default:

Enabled

Options:

Enabled, Disabled

Requires the Codabar start and stop characters (a, b, c, or d) to match before a valid read can occur.

2-26

MS-710 Scanner User’s Manual