MICROSCAN.

MS-/710 Scanner User's Manual

P/N 83-000700 REV I

Page 2

Copyright © 2000 by Microscan Systems, Inc., 1201 S.W. 7th Street, Renton, Washington, U.S.A. 98055 (425) 226-5700 FAX: (425) 226-8682 ISO 9001/Certification No. US96/0465 All rights reserved. The information contained herein is proprietary and is provided solely for the purpose of allowing customers to operate and/or service Microscan manufactured equipment and is not to be released, reproduced, or used for any other purpose without written permission of Microscan. Throughout this manual, trademarked names might be used. Rather than put a trademark (™) symbol in every occurrence of a trademarked name, we state herein that we are using the names only in an editorial fashion, and to the benefit of the trademark owner, with no intention of infringement.

Warranty Information Microscan Systems, Inc. warrants products manufactured by it to be free from defects in material or workmanship under normal use and service for a period of one year from date of shipment. This warranty is specifically limited to the replacement or repair of any such warrantable defects, without charge, when the complete product is returned to Microscan Systems, Inc., freight prepaid, at the address shown above. Contact the factory at the address above for a Return Material Authorization (RMA) number before returning the product. Microscan Systems, Inc. shall be the sole judge of the warrantability of alleged product defects. Products that are returned for warranty examination and that are found to be non-warrantable are chargeable and are returned freight collect. A copy of a purchase order with the amount of the charge must be received by Microscan, either by mail or by FAX, before any equipment is returned. Warrantable products are repaired or replaced at no charge and returned freight prepaid. THIS EXPRESS WARRANTY EXCLUDES ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PURPOSE. MICROSCAN SYSTEMS, INC., SHALL NOT BE LIABLE FOR WARRANTY IN ANY AMOUNT EXCEEDING THE PURCHASE PRICE OF THE GOODS. MICROSCAN SYSTEMS, INC., SHALL NOT BE LIABLE FOR ANY SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER IN CONTRACT, TORT, OR OTHERWISE. The buyer acknowledges that he/she is not relying on the seller's skill or judgment to select or furnish goods suitable for any particular purpose and that there are no warranties that extend beyond the description on the face hereof. This warranty extends only to the original purchaser, and shall not apply to any products or parts that have been subject to misuse, neglect, accident, or abnormal conditions or operations. Claims for damage in transit are directed to the freight carrier upon receipt.

Disclaimer The information and specifications described in this manual are subject to change without notice. For the latest version of this manual, see the Download page on our web site at www.microscan.com. For technical support email helpdesk@microscan.com.

ii

MS-710 Scanner User’s Manual

Page 3

Table of Contents Table of Contents ................................................................ iii List of Illustrations ................................................................v List of Tables ...................................................................... vi About the MS-710 Scanner .................................................. vii About This Manual .............................................................. vii Keystroke Entries ............................................................... vii Approvals .......................................................................... vii Warning and Caution Summary ........................................... viii Safety Labels ...................................................................... ix Zulassungen ........................................................................x Sicherheitshinweis und Vorsichtsmaßnahmen ...........................x Achtung/Warnung: .............................................................. xi

Chapter 1

Setup and Installation

Step 1 - Plan Scanning System ............................................ 1-2 Step 2 - Attach Cabling ...................................................... 1-3 Step 3 - Consider Read Range and Scan Width ...................... 1-4 Step 4 - Position Scanner ................................................... 1-5 Step 5 - Mount Scanner ...................................................... 1-6 Step 6 - Establish Communications ...................................... 1-7 Step 7 - Configure Scanner ................................................. 1-8 Step 8 - Test Decode Rate with Static Label .......................... 1-9 Step 9 - Test Decode Rate with Moving Label ...................... 1-10 Step 10 - Increase the Number of Scans ............................. 1-11

Chapter 2

Menu Configuration

About the Menu Configuration Program ................................. 2-2 Communications Menu ........................................................ 2-5 Protocol Menu .................................................................. 2-12 Operation Menu................................................................ 2-16 Code Type Menu............................................................... 2-25 Output Menu ................................................................... 2-32 Setup Menu ..................................................................... 2-38

Chapter 3

Serial Configuration

About Serial Configuration .................................................. 3-3 Communications Port Commands ......................................... 3-5 Protocol Commands ........................................................... 3-6 Operations Commands ..................................................... 3-10 Code Types Commands .................................................... 3-13 Scanner Output Commands .............................................. 3-15 Scanner Setup Commands ................................................ 3-18

MS-710 Scanner User’s Manual iii

Page 4

Chapter 4

Operational Commands

Read Rate ......................................................................... 4-3 Trigger.............................................................................. 4-5 Scanner ............................................................................ 4-6 Counters ........................................................................... 4-7 Master Label ...................................................................... 4-9 Reset .............................................................................. 4-11 Checksum ....................................................................... 4-13 Code Type Commands ...................................................... 4-15

Appendices Appendix A, Scanner Specifications ...................................A-2 Appendix B, Electrical Specifications ..................................A-5 Appendix C, ASCII Table ..................................................A-7 Appendix D, Orientation ...................................................A-8 Appendix E, Defaulting the Scanner ................................. A-10 Appendix F, Number of Scans ......................................... A-11 Appendix G, Troubleshooting .......................................... A-14 Appendix H, Using the IB-105 ........................................ A-18 Appendix I, MS-Sensor .................................................. A-24 Appendix J, Bar Code Symbology .................................... A-27 Appendix K, Interface Standards ..................................... A-28 Appendix L, Multidrop Communications ............................ A-29 Appendix M, Glossary of Terms ....................................... A-32

Index iv

I-1

MS-710 Scanner User’s Manual

Page 5

List of Illustrations Figure 1-1 Typical Setup (without IB-105) .............................................. 1-2 Figure 1-2 Auxiliary Port Setup .............................................................. 1-2 Figure 1-3 Daisy Chain Setup ................................................................ 1-2 Figure 1-4 DTE Host Connection ............................................................ 1-3 Figure 1-5 MS-710 External 15-pin Connector ......................................... 1-3 Figure 1-6 Read Range and Width .......................................................... 1-4 Figure 1-7 Tilt, Skew, and Pitch Axes ..................................................... 1-5 Figure 1-8 MS-710 Mounting Dimensions ................................................ 1-6 Figure 2-1 Configuration Program - Main Menu ........................................ 2-2 Figure 2-2 Communications Menu Structure ............................................ 2-5 Figure 2-3 Protocol ............................................................................ 2-12 Figure 2-4 Operation Menu Structure ................................................... 2-16 Figure 2-5 External Level Trigger Signals .............................................. 2-17 Figure 2-6 External Edge Trigger Signals .............................................. 2-18 Figure 2-7 Match Code Type ................................................................ 2-22 Figure 2-8 Code Types Menu Structure ................................................. 2-25 Figure 2-1 Symbology Identifier Option Values ...................................... 2-25 Figure 2-2 Scanner Output Menu Structure ........................................... 2-32 Figure 2-3 Setup Menu Structure ......................................................... 2-38 Figure A-1 MS-710 Dimensions .............................................................. A-2 Figure A-2 Low Density and High Density Scan Range/Width Graph ............ A-3 Figure A-3 Right-angle Down Scan Range/Width Graph ............................. A-3 Figure A-4 Grounding Diagram, Scanner-Host ......................................... A-6 Figure A-5 Ladder Orientation .............................................................. A-8 Figure A-6 Picket Fence Orientation ....................................................... A-8 Figure A-7 Angled Picket Fence Orientation ............................................ A-9 Figure A-8 Detector Orientation ............................................................. A-9 Figure A-9 Ladder Orientation ............................................................. A-11 Figure A-10 Picket Fence Orientation .................................................... A-11 Figure A-12 Label Dimensions ............................................................. A-12 Figure A-11 Angled Picket Fence Orientation ......................................... A-12 Figure A-13 Front of IB-105 ................................................................ A-18 Figure A-14 Back of IB-105 ................................................................. A-18 Figure A-15 MS-sensor Range ............................................................. A-25 Figure A-16 MS-sensor Flowchart ......................................................... A-26

MS-710 Scanner User’s Manual v

Page 6

List of Tables Table 1-1 Read Ranges and Scan Widths .......................................... 1-3 Table 1-2 RS-232 15-pin External Cable Connections ......................... 1-6 Table 1-3 RS-422/485 External 15-pin Cable Connections ................... 1-6 Table 2-1 Symbology Identifier Option Values ................................. 2-31 Table 3-1 Summary of Serial Configuration Commands .................... 3-2 Table 3-2 Protocol Commands ......................................................... 3-7 Table 4-1 Summary of Operational Commands.................................. 4-2 Table 4-2 Hex Value to Binary Conversion ........................................ 4-7 Table 4-3 Finding Scanner Status from Binary Bit Digits ..................... 4-7 Table A-1 External 15-pin 12-conductor Cable Connections ................. A-3 Table A-2 Range Data ....................................................................A-4 Table A-3 ASCII Table with Control Characters ..................................A-5 Table A-4 Troubleshooting ..............................................................A-9 Table A-5 6-pin Trigger Connector ................................................. A-13 Table A-6 15-pin Scanner Connector .............................................. A-13 Table A-7 5-pin Power Connector .................................................. A-13 Table A-8 25-pin D-sub Host Connector .......................................... A-13 Table A-9 6-pin LAN (RJ11) Connector ........................................... A-14 Table A-10 IB-105 Options ........................................................... A-14 Table A-11 Multidrop Address Characters ....................................... A-23 vi

MS-710 Scanner User’s Manual

Page 7

About the MS-710 Scanner The MS-710 is a programmable, fixed-mount, high-speed scanner that reads and decodes a wide variety of bar code labels using a 10-sided spinning mirror to project laser beams over a wide scan angle.

About This Manual This manual provides complete information on setting up and installing the MS-710 scanner. Chapter 1 provides overall step-by-step instructions for setting up and installing the MS-710 scanner with specific “go to” references to other chapters and appendices. Chapter 2 provides instructions for configuring the MS-710 scanner by menu. Chapter 3 provides instructions for configuring the MS-710 scanner by serial command. Chapter 4 describes serial operational commands that can be used by the host. For specifications, see appendix A. The appendices also include reference tables, as well as other useful information relating to bar coding and the MS-710 scanner.

Keystroke Entries Keystrokes to be entered from your terminal are highlighted, as in <P>. Serial commands and operational commands start with a < left angle bracket and are followed by a > right angle bracket.

Approvals This equipment is approved for use by the following organizations: • CDRH (Center for Devices & Radiological Health) • UL (Underwriters Laboratories, Inc.) • cUL (UL mark for Canada) • TüV (Technischer überwachungs-Verein) • FCC (Federal Communication Commission) • CE Compliant

MS-710 Scanner User’s Manual vii

Page 8

Warning and Caution Summary For connection to a UL Listed direct plug-in power unit marked Class II and rated at 5 VDC at 2 amps or greater. European Models must use a similarly rated Class I or Class II power supply that is certified to comply with the standard for Safety EN 60950. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help

WARNING Use of controls, adjustments, or performance of procedures other than those specified herein may result in hazardous laser light radiation exposure. WARNING There are no user serviceable parts in the MS-710 scanner. Opening the scan head voids the Microscan Systems warranty and could expose the user to laser diode power of up to 5 mW. WARNING The laser beam can be harmful to eyesight. Avoid eye contact with the laser beam. Never point the beam at other people, or in a direction where people may be passing.

viii

MS-710 Scanner User’s Manual

Page 9

Safety Labels These Class II labels are located on the MS-710 scanner.

LASER LIGHT IS EMITTED FROM THIS APERTURE

AVOID EXPOSURE M A N U FA C TU R E D

S ER I A L N U M B ER

VO R S I CH T

CA U TI O N L A S E R L I G HT D O N O T S T A RE

I NT O B E A M.

L IS T ED UL

L A S E R S T RA H L U NG , W E N N A B DE CK U NG G E Ö F F NE T . NI CHT I N DE N S T R A HL B L I CK E N

1 95 0

4 K6 8

FI S

®

®

LASERSTRAHLUNG NI CHT IN

6 7 0 n m L A S E R D I O DE 1 . 0 MI L L I WA T T MA X

DEN STRAHL BLI CKEN LASER KLASSE 2 nJ @ 38uS

M

IC R OS C A N

S Y S T E M S , I n c.

1 2 0 1 SW R e nt on , W A

E N 6 08 2 5 - 1 : 1 9 9 4

7t h S t . 9 80 5 5 g epr ü f te T U V R h ei nl an d

1 1 -1 2 0 0 2 3 -0 1

Sc i h er he i t

G D/RD

RDY

PWR 5 V

65 0 m A

DI N V DE 08 3 7 T ei l 1 : 1 99 4 - 0 7

C L A S S I I L A S E R P R O D UCT

CAUTION- LASER LIGHT WHEN OPEN-DO NOT STARE INTO BEAM. PRODUCT CONFORMS TO USA DHHS 21 CFR SUBCHAPTER "J"

Side

Back

MS-710 Scanner User’s Manual ix

Page 10

Zulassungen Dieses Gerät wurde für die Zulassung durch die folgenden Organisationen und in Übereinstimmung mit deren Normen entwickelt: CDRH (Center for Devices & Radiological Health; Zentrum für Geräte und Strahlenschutz) UL (Underwriters Laboratories, Inc.) cUL (kanadisches UL-Zeichen) TüV (Technischer Überwachungsverein) FCC (Federal Communication Commission; Kommunikationsausschuß der USA) CE konform

Sicherheitshinweis und Vorsichtsmaßnahmen Diese Gerät wurde geprüft und entspricht den Grenzwerten für ein digitales Gerät der Klasse A gemäß Teil 15 der FCC-Richtlinien. Diese Grenzwerte bieten ausreichenden Schutz vor schädlichen Störungen bei einer Installation in Wohnräumen. Dieses Gerät kann Hochfrequenzstrahlung erzeugen, verwenden und abgeben. Wenn es nicht den Anleitungen entsprechend installiert und verwendet wird, kann es zu Funkstörungen kommen. Es gibt jedoch keine Garantie, daß bei bestimmten Installationen keine Störungen auftreten. Sie können feststellen, ob dieses Gerät den Funk- oder Fernsehempfang beeinträchtigt, indem Sie es ein- und ausschalten. Versuchen Sie in diesem Fall, die Störung mit Hilfe einer der folgenden Methoden zu beheben: • Richten Sie die Empfangsantenne anders aus, oder wählen Sie einen anderen Standort. • Erhöhen Sie den Abstand zwischen diesem Gerät und dem Empfangsgerät. • Schließen Sie dieses Gerät an eine Steckdose eines anderen Stromkreises als dem des Empfangsgerätes an. • Setzen Sie sich mit dem Händler oder einem erfahrenen Funk- und Fernsehtechniker in Verbindung. Dieses Gerät darf nur an eine VDE geprüfte Spannungsversorgung 5V ··· angeschlossen werden. Die SELV Spannungsversorgung muß mindestens 2 A. Modelle für den europäischen Markt müssen eine entsprechende Stromversorgung der Klasse I oder II verwenden, die nach der Sicherheitsrichtlinie EN 60950 zertifiziert ist.

x

MS-710 Scanner User’s Manual