The text of a manual · part 18 of 19
Series 4000 Raster Scanner User's Manual: Appendix G
Pages 129 to 133 of 137, from Series 4000 Raster Scanner User's Manual
The original document is the PDF (5.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-4280
Page 129
Appendices
_ Appendix G, Glossary of Terms
Autodiscriminate. The ability to decode various bar code symbologies without having to change scanner functions.
AWG. Abbreviation for American Wire Gauge. This is a standard measur-ing system for wire sizes, listed from 0 (biggest) to 40 (smallest). A 26 AWG is equivalent to .0159 in. (0.405 mm) in diameter.
Bar Code. Data that has been encoded Into an array of parallel bars and spaces of varying widths.
Bar Code Density. Number of characters per inch or other unit of measure.
Baud Rate. The term used to describe the number of discrete conditions or signal events per second. In RS-232 and RS-422/485 systems, baud rate is the same as bits per second (bps).
Blurring. Congestion of bars and spaces, typically occurring when scanning at severe angles and/or distances, to a point that the scan beam is distorted and individual bar code elements are not discerned.
CODE 39. An alphanumeric bar code with a character set containing a start/stop character, 10 numbers, 26 letters, 6 symbols, and a space. This code is discrete, variable length, and self-checking.
Concentrator. Intermediary device which communicates with up to 50 other devices, and relays data from those devices to the host as well as commands from the host to the devices.
Configuration. The method used to change factory default settings for operational features to match a specific application. Configuration can be done through menu selection, or with serial commands.
Connector. Physical device (plug or socket) on unit to provide in/out con-nectivity for various circuits and pins.
Counter. Memory space provided to keep track of read cycle events.
Decoder. A device that analyzes digital input provided by the scan head and translates it into bar code information.
Depth of Field. The range in which a scanner is focused for bar code reading, as measured from the front of the scanner. See "Read Range."
EPROM. Erasable, programmable, read only memory. The EPROM stores the coded information that contains decoding algorithms and options that can be changed by the user.
A-14 Series 4000 Raster Scanner User's Manual
Page 130
Appendix G, Glossary of Terms
End of Read Cycle. The time at which the scanner stops expecting label information to decode. This can be caused by a timeout, a trigger event, or a good read.
Focal Length. The distance measured from the scanner to the center of the depth of field, or foca/ point.
Good/Bad Pulses. TTL signals sent by the scanner to indicate to a controlling device that a good or bad read has occurred.
Good Match. The event which occurs when a scanned bar code label matches the master label information that is stored in the memory of the
- Scanner.
Good Read. The event which occurs when a label's data is accurately scanned and decoded.
Intercharacter Gap. The extra space between the last element of one character and the first element of the adjacent character of a discrete bar code symbol.
Label Height. Regardless of orientation, the measurement taken along the length of a bar.
Label Length. Regardless of orientation, the measurement taken across the label's bars from one end to the other, including the quiet zone.
Label Speed. The rate in inches or centimeters per second that a label moves through the scan beam.
Ladder Label Orientation. A bar code label i in which the bars are parallel to the direction of travel.
Match Code. The ability to compare bar code labels being scanned against a master label that is stored in the memory of the scanner.
Menu Configuration. The process of changing factory default settings via a sequence of menus displayed on a terminal monitor.
Mil. One thousandths of an inch or .0254 mm. In bar-coding, a measurement that identifies a bar code label by the width of its narrowest element.
Mismatch. A mismatch occurs when the scanned bar code label does not match the master label that is stored in the memory of the scanner.
Multidrop. A communications protocol for networking two or more decoders or other devices with a concentrator (or controller) and character-ized by the use of individual device addresses and the RS-485 standard.
Series 4000 Raster Scanner User’s Manual A-15
Page 131
Appendices
A-16
Narrow Bar Width. The width of the narrowest bar of a given label, expressed in thousands of an inch (or mils).
Non-read. (Also called “no read”) The absence of data at the scanner output after an attempted scan due to no code, defective code, scanner failure or operator error.
Number of Scans Calculation. The number of times a bar code label is scanned by the scanner during one pass through the laser beam.
Object Detector. A photo electric device used to sense to presence or absence of an object.
Operational Commands. Classified as serial commands, operational commands are used to change day-to-day operating parameters. With only a few exceptions, the structure consists of a less than (<) symbol, a capital letter, and a greater than (>) symbol.
Oval Spot. An elongated laser beam involving custom optics that is designed to project lengthwise with the label's bars and spaces.
Picket Fence Label Orientation. A bar code label in which the bars are perpendicular to the direction of travel.
Pitch. Label (or scanner) rotation around the center of the X-axis.
Point-to-Point. A protocol consisting of a single communications event, typically used to connect a bar code reader to a CRT terminal or a host computer.
Polled Protocol. A communication protocol in which the host requests information from the scanner by means of an address.
Port. Circuit for data entry and exit. (One or more ports may be included within a single connector.)
Protocol. The rules for communication between devices, providing a means to control the orderly communication of information between linked devices.
Quiet Zones. Specified “clear” (nonprinted) areas immediately before and after the bar code symbol. The area is usually white (for black and white bar code) and at least 10 times the width of the narrowest bar, as measured in thousands of an inch. The zones can be other than white as long as their densities remains consistent and they have the required contrast relative to the bars.
Read Cycle. A programmed period of time or condition during which the scanner will accept bar code label input.
Series 4000 Raster Scanner User’s Manuat
Page 132
Appendix G, Glossary of Terms
Read Range. The distances in which a label can be reliably read, as measured from the front of the scanner. See "Depth of Field. "
Read Rate. The reading performance of the scanner for a given label based on the percentage of good reads per a determined number of scans.
Relay Driver. A TTL signal sent by the scanner. The output is determined by the relay driver selection during configuration.
Round Spot. The standard laser beam as it appears on the label being scanned, sometimes slightly ovalized.
Scanner. A scanning device which is comprised of a scan head and a decoder combined into one package.
Scan Head. The module that projects laser light on bar code labels and receives reflected light back. This device changes the analog signal to a digital representation of the bar code and outputs it to a decoder.
Scan Rate. The number of times the scanner scans per second.
Scan Width. The measurement (inches or centimeters) of the scan beam line at the readable scan range of a given application.
Serial Commands. The classification of commands that are generated by the following structure: a less than (<) symbol, specific command datum, and a greater than (>) symbol.
Serial Configuration. The method of changing factory default settings via command strings. The structure consists of a less than (<) symbol, a capital K, a parameter letter, configuration data, and a greater than (>) symbol.
Skew. Label (or scanner) rotation around the center of the Y-axis.
Specular Reflection. The direct, mirror-like reflection of laser light back to the scanner, causing over-light saturation.
Symbology. A set of bar code symbols, such as Code 39 or Code 128, which have special rules to define the widths and positions of bars and spaces to represent specific numeric or alphanumeric information.
Tilt. Label (or scanner) rotation around the center of the Z-axis.
Timeout. A user-selected period of time that ends a scanner's read cycle.
Trigger. A signal, either external or serial, that initiates the read cycle and causes the scanner to expect label input.
Series 4000 Raster Scanner User's Manual A-17
Page 133
Appendices
TTL. Abbreviation for transistor-transistor logic, the standard for signal output.
Wide-to-narrow Ratio. The ratio of the width of the widest (or wider)
bar to the narrowest bar of a given bar code symbology. For example, 2:1, 2.5:1, 3:1, and 4:1.
A-18 Series 4000 Raster Scanner User's Manual