The text of a manual · part 17 of 19
Series 4000 Raster Scanner User's Manual, pages 126 to 128
Pages 126 to 128 of 137: Appendix D; Appendix E; Appendix F
The original document is the PDF (5.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-4280
Page 126
Appendix D, Bar Code Symbology
Appendix D, Bar Code Symbology
Some factors to consider before choosing a bar code symbol are:!
e the type of information * scan speed to be scanned (numeric °
, beam width only, alphanumeric)
e the space available on the
° the length of the mes- object to be identified sages to be encoded ae e host software limitations e how and where labels are to be applied ¢ range of the scanner ° label printer capabilities ° the speed of the conveyor
Microscan standard decoder firmware supports the following five bar code symbologies. (Firmware can also be custom ordered to support other symbologies.)
Code 39. An alphanumeric code with unique start/stop code patterns, composed of 9 black and white elements per character, 3 of which are always wide.
Codabar. A 16-character set (0 through 9, and the characters $, :, /, ., +, and -) with start/stop codes and 18 different bar widths.
1 2 of 5. Interleaved 2 of 5 is a high-density, continuous numeric symbology. | 2 of 5 encodes two digits: one in the bars, and one in the spaces. (A check digit is highly recommended.)
UPC and EAN. UPC (Universal Product Code) is a fixed length numeric, continuous symbology. The European Article Numbering system (EAN) is a well-known variation of UPC. Both UPC and EAN can have 2 or 5 digit supplemental bar code data following the normal code.
Code 128. A very high density alphanumeric symbology. Will encode all 128 ASCII characters, it is continuous, has variable length, and uses multiple element widths measured edge to edge.
1. For further information about symbology, see The Bar Code Book, by Roger C. Palmer, Hermers Publishing, Inc., 1989.
Series 4000 Raster Scanner User’s Manual A-11
Page 127
Fal 4
Appendices
Appendix E, Interface Standards
Interface Standards, established by the Electronic Industries Association (EIA), specify such things as the signaling voltage levels, maximum cable lengths, and number of drivers. With Microscan devices, selection of interface is made by pin assignment and, in the case of the host communications, by software switching between RS-232 and RS-422. Microscan devices use RS-232, RS-422, and RS-485 multidrop.
RS-232
RS-232 defines an interface between two devices such as, for example, the scanner and host. It differs from the other interfaces by dedicating individual pins to specific functions and by requiring both devices to share a common ground line. Since both device chassis are connected to a common ground, a ground loop potential and the possibility of noise interference exists. Therefore cable lengths are limited to a maximum of 50 feet (19.7 m). Despite being the most limited, this interface is used frequently because of the large installed base of RS-232 equipment.
RS-422
RS-422, unlike RS-232, measures signals differentially that is, the receiver looks at the potentials between the two receive (or transmit) wires rather than the potential between signal and ground. As a result, cables, if shielded, can be up to 4000 feet (1575 m) in length. Like RS-232, RS-422 communication is designed for only two devices on a single line. It can be used wherever RS-232 is used.
RS-485
RS-4885, like RS-422, can transmit up to 4000 feet (1575 m) using differential voltages but unlike RS-422, its transmitters are turned off until a request for data is received from the host. RS-485 is used exclusively in Multidrop protocol.
NOTE: See “Protocol” in chapter 3, “Configuration,” for additional information on standards.
A-12 Series 4000 Raster Scanner User’s Manual
Page 128
Appendix F, Binary Calculation for the Profile Card
Appendix F, Binary Calculation for the Profile Card
Data switch settings for values 51-255 must be determined by the user with binary calculation. (Specifically, the timeout values for 51-255 in mode 9 and various serial trigger character selections in mode 10.)
The eight data switches on the profile card represent the eight data bits that define any number from 0 to 255 in binary format. To convert a number to its binary equivalent: 1. Determine which decimal equivalent (1, 2, 4, 8, 16, 32, 64, 128) is the largest number not exceeding the original number to convert. (See table A-6.)
2. Put a one (1) above that number. A one (1) in a column represents an ON position for that data switch.
For example, table A-6 shows the calculation process for the number 250. The first one (1) is placed in the eighth bit column over the number 128, since that is the largest possible decimal equivalent to use.
Table A-6 Calculating Binary Conversion
1 Data Switches (Bit Representation)
23 4 5 67 8 O}[@][O][@][@][@][@][@] data switch setting
1 +[1]7[1]4
2
Binary Code = ON 10 | 26 | 58} 122 Remainder Numbers [O] = OFF 250 Original Number to Convert
1} 2 | 41 8 | 16] 32| 64:128) Decimal Equivalent
3. Subtract the decimal equivalent from the original number.
4. Place the remainder above the next largest decimal equivalent that does not exceed the remainder number.
5. Put a one (1) above that number. 6. Continue this process until the remainder equals zero (0), as follows:
290 -128=122, -64=58, -32=26, -16=10, -8=2, -2=0
OFF positions on the data switches result from:
¢ Decimal equivalent numbers passed over because they are greater than the remainder (the third bit in table A-6), e Decimal equivalent numbers not used because the formula has termi-nated with a remainder of zero (0) (the first bit in table A-6).
Series 4000 Raster Scanner User's Manual A-13