Page 108 read from a scan by OCR; it may hold reading errors

Operational Commands

Chapter Contents Operational ComMand .............cecccccececeeesessseeeeeeeseeeesseeses 4-2 Summary of Serial Operational Commands...............eee 4-8

This chapter includes a description of all serial operational commands and their functions, followed by a one page summary of the same commands.

NOTE: Operational commands should not be confused with configuration “operations” described earlier in chapter 3, “Configuration.”

Online serial operational commands are sent from the host to the scanner to carry out routine operations “on the fly” as distinguished from serial configuration commands which are generally used in Initial setup.

Operational commands are always preceded by a < left angle bracket symbol (unless redefined by Command Start Character command) and followed by a > right angle bracket symbol.

Page 109 read from a scan by OCR; it may hold reading errors

Chapter 4 Operational Commands

Operational Commands

<A> Software Reset

Initializes all serial configuration commands and resets all counters and operating parameters. Settings for Baud Rate, Stop Bits, Code Length, etc. do not change until this command is sent. If the numeric counters are being used, It is recommended that data be collected prior to sending this command.

<C> Enter Read Rate Test

Instructs the scanner to output the percentage of scans decoded of a given label. The read rate can vary dramatically as the angle and location of the label changes in relation to the scan line. This test is very useful in aligning and positioning the scanner during installation. See “Read Rate Test” in chapter 2, “Setup and Installation.”

The displayed message is in the form of XXX% actual bar code data.

Send a <J> Exit Read Rate Test command to the scanner when testing is complete.

<D> Enter Configuration Mode

Used to enter the menu configuration program. See chapter 3, “Configuration.”

<E> Enter Match Code Option Identical to match code command in chapter 3, “Configuration.”

Instructs the scanner to compare bar code labels being scanned with a master label that has been entered in non-volatile or volatile RAM.

Enter Match Code Option is intended for use when the scanner is in a triggered mode. If the Match Code option is enabled in the Continuous Read mode, the scanner defaults to Continuous Read One Output mode, and the label data must change before the scanner will output data again, unless a timeout, if enabled, occurs.

See “<G> Store Next Label Scanned as Master Label” and “<)XXXXX)> Download Master Label Information” in this chapter. See also, “Relay Driver” in chapter 3, “Configuration.”

4-2 Series 4000 Raster Scanner User's Manual

Page 110 read from a scan by OCR; it may hold reading errors

Operational Commands

<F> Exit Match Code Option Disables Match Code.

<G> Store Next Label Scanned as Master Label

Causes the scanner to use the next bar code label read as the master label if Match Code option has been enabled. All subsequently decoded labels are compared against the master label information stored in RAM. (See “Match Code” in “Operations Menu,” chapter 3.)

<H> Enable Laser Scanning Enables laser scanning.

<I> Disable Laser Scanning

Disables laser scanning. This feature can be used when there are extended periods of time during which no bar code labels are being scanned. Disabling laser scanning will not affect any downloaded commands to the scanner. The scanner remains active during this period.

<J> Exit Read Rate Test

Exits the read rate test.

<Kdata> Serial Configuration Commands

All commands beginning with the letter K are classified in chapter 3 as Serial Configuration commands (also called “K" commands). Generally, these commands parallel the menu configuration options accessible through the menu configuration program discussed in chapter 3, “Configuration.”

<L> Host Relay Driver

Sends a pulse to pin 2 of the trigger connector. Allows the user to send a pulse to pin 2 at any time regardless of Match Code or Relay Driver status.

<N> Noread Counter

Used to obtain the total number of noreads (nonreads) that have occurred since power-up or the last Noread Counter Reset command. The noread counter is incremented by one each time a triggered read cycle is com-pleted and no bar code information has been decoded.

Series 4000 Raster Scanner User’s Manual 4-3

Page 111 read from a scan by OCR; it may hold reading errors

Chapter 4 Operational Commands

4-4

NOTE: If the Noread. Counter command ts invoked during a read cycle, the scanner will not output a noread count until the read cycle ends, or a good read occurs.

Noread Counter message is in the form of N/XXXXX, where the X's denote a numeric value from 00000 to 65,535. If the counter exceeds the value of 65,535, an error message is displayed the first time Noread Counter is invoked. The error message is in the form of: N/ERROR. After reaching the maximum numeric limit of 65,535 the noread counter will automatically roll over and start counting again at 00001. To obtain the total number of noreads after the error message is received, the next value obtained by a Noread Counter command can be added to 65,535. This statement is true only if the noread counter has rolled over one time.

NOTE: All counter values are stored in volatile memory, and will be lost if power to the scanner is cycled.

<0> Noread Counter Reset Sets Noread Counter to 00000.

<P> Autodiscriminate All Codes

Enables the scanner to decode all available bar code types without changing scanner configuration settings.

NOTE: For maximum scanning speed, enable only those bar code symbologies used in the application.

<Q> Enable Code 39 Only

Allows only Code 39 labels to be read.

<R> Enable Codabar Only

Allows only Codabar labels to be read.

<S> Enable | 2 of 5 Only

Allows only Interleaved 2 of 5 labels to be read.

Series 4000 Raster Scanner User’s Manual

Page 112 read from a scan by OCR; it may hold reading errors

q

Operational Commands

<T> Trigger Counter

Used to obtain the total number of triggers since power-up or the last Trigger Counter Reset command.

Trigger Counter is incremented by one each time the scanner is triggered.

NOTE: If the trigger count is requested during a read cycle, the scanner will not output the trigger count until the read cycle ends or a good read occurs.

Trigger Counter message is in the form of T/XXXXX. The Xs denote a numeric value from 00000 to 65,535. If the counter exceeds the value of 65,535 an error message (T/ERROR) is sent the first time the trigger counter is requested. After reaching the maximum numeric limit of 65,535, the trigger counter will automatically roll over and start counting again at 00001. To obtain the total number of triggers after an error message is received, the next value obtained by request for number of triggers can be added to 65,535. This statement is true only if the trigger counter has rolled over one time.

NOTE: All counter values are stored in volatile memory and will be lost if power to the scanner is cycled.

<U> Trigger Counter Reset Sets the trigger counter to 00000.

<V> Match Counter (or Good Read Counter)!

Used to obtain the total number of good reads matching the master label since power-up or the last Match Counter Reset command. This counter is always enabled, but will only work as a match counter if the decoder is in a triggered mode, Match Code option is enabled, and a master label has been downloaded into the decoder’s memory. If this is not the case, the counter counts all of the good reads. This count can be requested at any time.

NOTE: If the Match Counter command is invoked during a read cycle, the scanner will not output the match count until the read cycle ends or a good read occurs.

1. Can also be used as a good read counter when Match Code is not enabled.

Series 4000 Raster Scanner User’s Manual 4-5

Page 113 read from a scan by OCR; it may hold reading errors

y

Chapter 4 Operational Commands

Match Counter message is in the form of V/XXXXX. The Xs denote a numeric value from 00000 to 65,535. If the counter exceeds the value of 65,535, an error message (V/ERROR) is sent the first time Match Counter command is invoked. After reaching the maximum numeric limit of 65,535, the counter will automatically roll over and start counting again at 00001. To obtain the total number of matches after an error message is received, the next value obtained by the Match Counter command can be added to 65,535. This statement is true only if the Match Counter has rolled over only once.

NOTE: All counter values are stored in volatile memory and will be lost if power to the scanner is cycled.

<W> Match Counter Reset! Sets the Match Counter to 00000.

<X> Mismatch Counter

Used to obtain the number of labels successfully read that do not match the master label since power-up or the last Mismatch Counter Reset command, provided that Match Code has been enabled, a master label has been downloaded into decoder memory, and the decoder is in a triggered mode.

NOTE: Ifthe Mismatch Counter command is invoked during a read cycle, the scanner will not output the mismatch count until the read cycle ends or a mismatch occurs.

Mismatch Counter message is in the form of X/XXXXxX. The Xs denote a numeric value from 00000 to 65,535. If the counter exceeds the value of 65,535, an error message is sent the first time the Mismatch Counter command is invoked. The error message is in the form of X/ERROR. After reaching the maximum numeric limit of 65,535, the Mismatch Counter will automatically roll over and start counting again at 00001. To obtain the total number of good reads after an error message is received, the next value obtained by the Mismatch Counter command can be added to 65,535. This statement is true only if the Mismatch counter has rolled over only once.

NOTE: All counter values are stored in volatile memory and will be lost if power to the scanner is cycled.

1. Will also reset good read count if Match Code has not been enabled.

4-6 Series 4000 Raster Scanner User's Manual

Page 114 read from a scan by OCR; it may hold reading errors

Operational Commands

<Y> Mismatch Counter Reset Sets the Mismatch Counter to 00000.

<Z> Save Configuration Saves the current configurations to non-volatile memory for availability on power-up.

The values of numeric counters such as the number of matches, mis-matches, etc. are not saved by <Z> Save Configuration.

NOTE: The <Z> Save Configuration command can be executed 10,000 times. In normal usage this will exceed the life of the scanner. If frequent changes to the operating parameters are required, it is recommended that the <Z> command be used only before shutdown or whenever power interruption is anticipated.

<m> Scans per Second Displays the number of scans per second projected by the spinning mirror.

<)XXXX)> Download Master Label Information

Downloads master label information from the host or a terminal. The master label information can be downloaded at any time, and can be saved in non-volatile memory with a <Z> command. A stored master label will not affect standard operations unless Match Code option is enabled.

The Xs denote alphanumeric data, from 1 to 31 characters.

<))> Delete Master Label Information

Deletes master label information that has previously been loaded by either <)XXXX)> Download Master Label Information Command or <G> Store Next Label as Master Label command.

NOTE: If the master label information has previously been stored in non-volatile RAM (by a <Z> command), cycling the power will restore that information.

<#> Display Software Part Number

Displays software part number.

</> Display Checksum of EPROM

Displays a four-digit hex number (corresponding to a given firmware version) used to verify a scanner’s EPROM.

Series 4000 Raster Scanner User's Manual 4-7

Page 115 read from a scan by OCR; it may hold reading errors

Chapter 4 Operational Commands

Summary of Serial Operational Commands

Table 4-1 Serial Operational Commands

Command Result <A> Software Reset (does not save for power-up) <C> Enter Read Rate Test <D> Enter Configuration Mode <E> Enter Match Code Option* <F> Exit Match Code Option* <G> Store Next Label Scanned as Master Label <H> Enable Laser Scanning <I> Disable Laser Scanning <J> Exit Read Rate Test

<Kdata> Serial Configuration Commands <L> Host Relay Driver <N> Noread Counter <O> Noread Counter Reset <P> Autodiscriminate All Codes <Q> Enable Code 39 Only* <R> Enabie Codabar Onty* <S> Enable | 2 Of 5 Only* <T> Trigger Counter <U> Trigger Counter Reset <V> Match Counter (or Good Read Counter) <W> Match Counter Reset (or Good Read Counter Reset) <X> Mismatch Counter <Y> | Mismatch Counter Reset <Z> Save Configuration for Power-up <m> Scans per Second <)XXXX)> Download Master Label Information

<))> Delete Master Label Information <#> Display Software Part Number <!> Display Checksum of EPROM

* Can also be accomplished in configuration menu or serial configuration command.

4-8 Series 4000 Raster Scanner User’s Manual