Page 104
Operations Settings Mode 7: Triggering Mode, End
Profile Card Configuration of Read Cycle
Mode Switches: |@/@|@/O|
[@|=ON [Q] = OFF
Data Switches
TRIGGERING MODE: 1|2|3| ENDOFREADCYCLE: | 4|5 Continuous Read |O| O|}O Timeout |C }O Continuous 1 Output |@ | O|O New Trigger | @|O External Level ©] @[O Timeout & N Ole ew Trigger External Edge |@| @|O Serial Data |O|O|® Serial Data & Edge | @|O|®@®
Mode 8: Bar Code Output, When to Output, External Trigger Polarity, Match Code, Noread Message
Mode Switches: [O/O/[O[@]
[@|-on [O]=O0FF
Data Switches
EXTERNAL BAR CODE WHEN TO TRIGGER MATCH NOREAD OUTPUT: | 1 OUTPUT: POLARITY: 3 CODE: | 4) MESSAGE: | 5 Disabled |©| As Soon As 5 Neg. |O| Disabled|O| Disabled |O Possible Enabled |@ Pos. Enabled Enabled End of Read Cycle
Series 4000 Raster Scanner User’s Manual
3-71
Page 105
Chapter 3 Configuration
Mode 9: Timeout
Mode Switches: leicl0le
Since the number of profile card settings is limited to 255, read cycle timeouts entered from the profile card can only affect a range from 0.1 seconds to 25.5 seconds, in tenths of a second.
To set Timeout, multiply the desired number of seconds for trigger timeout by 10 and enter the result in binary format.
See mode 1 swith settings for timeout ranges from 0.1 seconds to 5 seconds. (Although not shown for mode 1, switches 7 and 8 are OFF for 1 through 50.)
See appendix F, “Binary Calculation for the Profile Card” for timeout ranges from 5.1 seconds to 25.5 seconds.
Mode 10: Serial Trigger Character
Mode 10 allows the user to set the serial trigger character by using the ASCII table (appendix B) to look up decimal values and corresponding characters. A few examples are provided below. See “Binary Calculation for the Profile Card,” appendix F, if selecting values from 51 to 255.
Mode Switches: |[O|@|O|@ [@]-on [G]-orF
Data Switches
SAMPLE ASCII
SERIAL TRIGGER REFERENCE ASCIil CHARACTERS: NUMBER: 1; 2/3); 4) 5; 6|7;8 A] 29 |@[Olelele[Ololo { 49 |@(OlOlOCl@/@/C/O 6 (@/OlOlOlOlC/@[O Zz 90 |O|@|0|@/@/Ol@|O
3-72 Series 4000 Raster Scanner User's Manual
Page 106
Profile Card Configuration
Mode 11: Number of Reads before a Good Decode Mode Switches: [(@/@/OC/@! [(@|=on [O]=OFF
The range for Number of Reads before a Good Decode is 1-31. See “Mode 1” for switch settings.
Code Types Settings
Mode 12: Code 39, Codabar, | 2 of 5, UPC, Code 128, Narrow Margins
Enabling data switches 1 through 5 will autodiscriminate for all code types. -
Mode Switches: C/|C!@/@ [(@|}=on [O]= OFF
Data Switches
| CODE 39: n CODABAR: [2] 12 OF 5: Disabled |C| Disabled |‘O Disabled |O
Enabled Enabled Enabled
3
Data Switches f ” NARROW UPC: | 4 CODE 128: | 5 MARGINS: =
Disabled | © Disabled|O© Disabled |O Enabled Enabled Enabled
Series 4000 Raster Scanner User's Manual 3-73
Page 107
Chapter 3 Configuration
User Outputs Settings
Mode 13: Beeper Volume, Beeper Enable
Mode Switches: |@/C)/@/@| [@]-on [O]=orF
Data Switch BEEPER VOLUME: 1] 2 3 | BEEPER ENABLE: 4|5 Level 1 C}O!O Disabled |O|© Level 2/@[ O10) On Good @ 5 Level 3|}0,@ O On Noread |O|@| Level 4,@| @)O Level 5|C|O|@
Mode 14: Relay Driver, Full Screens, Good/Bad Polarity, New Master Pin, Laser On/Off, Reverse Video
Mode Switches: |C|/@/@/@| [@|-on [O]-orF
Data Switches
RELAY FULL GOOD/BAD |
DRIVER: 1| 2] SCREENS: [3] POLARITY: [4] Good |C|O Disabled| © Negative|O Match
Mismatch _@|O Enabled Positive Noread |O|@
Mismatch e@ | e or Noread
NEW
LASER MASTER PIN: | 5 ON/OFF: [6| ‘ VIDEO: [7]
REVERSE
Disabled |O Disabled |©O Disabled |© Enabled Enabled Enabled.
3-74 Series 4000 Raster Scanner User's Manual