Using ESP

Model

In Model you can select any of the models shown in ESP’s model menu. When you choose another model, your current connection to your present model will be terminated. To connect to another model, select New Model, choose a new model from the menu, and click OK.

Note: All the models you have enabled by selecting will continue to appear in the Model menu and that the same menu is repeated when clicking the Switch Model icon.

When you save your ESP file, you will be saving the settings of all the models defined in a single ESP file. MS-4 Imager User Manual

2-5

Page 32

Menu Toolbar

Options

The Options menu allows you to save memos and set up ESP Preferences. Note: Preferences will be saved and loaded into ESP when ESP is opened next, whether or not you save the ESP file.

Preferences General Tab

Reload Last File At startup, reloads the last file saved to the host computer’s hard drive. Show Model Prompt At startup, shows the model menu displaying all supported readers. Skip EZ Mode At startup, skips EZ Mode and opens directly in App Mode. Show Connect Prompt At startup, displays the Would you like to connect...? prompt. Receive After Connect At startup, loads the Imager’s settings into ESP. (This is not recommended if you want to preserve your ESP settings for future use.) Enable Send and Save as Customer Defaults At startup, enables the Send and Save as Customer Defaults option in the Send/Recv command.

2-6

MS-4 Imager User Manual

Page 33

Using ESP

Terminal Tab

When Show Non-Printable Characters is checked, characters such as “CRLF” will be displayed in the Terminal window. When Enhanced Format is checked, the characters are displayed with more detailed formatting. Change Keyboard Macros In this dialog you can first select the function key and then enter your macro keystrokes in the associated key map. For example, to make Ctrl-F5 the keystroke to enable, send a trigger character, select F5, and then in the Ctrl row, enter <trigger character> and click OK. Then whenever the Ctrl-F5 keystroke is pressed, the trigger character will start the read cycle. Change Font Allows you to modify the font used for decode data received from the Imager on the Terminal screen. Change Echo Font Allows you to modify the font used for command characters typed into the Terminal view. Toolbar Style Displays user-selected toolbar buttons as icons, text only, or both (default).

MS-4 Imager User Manual

2-7

Page 34

Menu Toolbar

Bar Code Options Tab

The Bar Code Options dialog allows you to set the size (in mils) of user-created symbols. Sizing Information Sets the bar width (in thousands of an inch) of user-created symbols. A bar width of 14 is 0.014 inches.

2-8

MS-4 Imager User Manual

Page 35

Using ESP

Grade Report Options Tab

Overall Grade Based On Allows you to choose which symbol characteristics will be considered in generating a symbol quality grade. Use Number Grades Allows you to switch from the default letter grades to number grades in symbol quality report output. Show Report Options during ‘Generate Report’ Sets the symbol quality report output to show the complete array of report options. Include Image Sets the symbol quality report output to include a captured image of the symbol being analyzed. Bitmap and JPEG image formats are both available. Bitmap images, although higher resolution, have larger file sizes and take longer to load.

MS-4 Imager User Manual

2-9

Page 36

Menu Toolbar

Advanced Tab

The Auto Sync dialog at the top of the Advanced tab allows you to determine whether Auto Sync will be automatically enabled in sections of ESP where it is used, or if it will ask you before it enables Auto Sync functions. Always Ask Before Auto Sync Occurs If you check this option box, you are then able to determine what specific Auto Sync functions will be enabled. Receive Settings from the Reader will automatically send the Imager’s settings to ESP when Auto Sync is enabled. Send ESP Settings to the Reader will automatically send all Imager configuration settings chosen in ESP to the Imager. Do Not Send or Receive Settings creates a condition in which Auto Sync will not send Imager settings to ESP, or send ESP settings to the Imager. Show Targeting Pattern During Calibrate and Locate Allows you to determine whether the blue LED target pattern will be on or off during the Locate and Calibrate routines. Send XON with Autoconnect Sends an XON (Begin Transmission) command to the Imager before starting the Autoconnect routine.

2-10

MS-4 Imager User Manual

Page 37

Using ESP

Document Memo

The information you type in the Document Memo field will appear in a context-sensitive text box whenever your cursor hovers over the Document Memo item on the Options menu.

Model Memo

Similar to Document Memo, the information you type in the Model Memo field will appear in a context-sensitive text box whenever your cursor hovers over the Model Memo item on the Options menu. Memos created in Model Memo are specific to the model enabled when the message was created.

Note: Memos must be saved in a .esp file if you want them to available in your next session. If you do not save your current session, any memos that you have entered during the session will be discarded, and will be unavailable in your next session.

MS-4 Imager User Manual

2-11

Page 38

Connecting

Connecting When you open ESP and the Select Protocol dialog appears, choose either RS-232 or USB protocol and click Next. The MS-4 Imager’s default trigger mode is Continuous Read Mode. The USB version of the MS-4 will be in a keyboard wedge configuration, causing ESP to receive incoming symbol data as keyboard text. This will interfere with the connection attempt and cause it to fail. Be sure that no symbols are within the Imager’s field of view while connecting to ESP.

If you choose USB protocol:

If you choose RS-232 protocol:

Select the MS-4 from the Select Device menu and click Finish.

Click Connect.

When you are connected, you will see the green connection indicator in the status bar at the bottom right of your screen. USB: RS-232: Important: If you are using an RS-232 interface and your connection attempt fails, click the Autoconnect button, select a different communications port, and try again. Note: If your RS-232 host settings cannot be changed to match the Imager’s settings, check the Force Connect box. 2-12

MS-4 Imager User Manual

Page 39

Using ESP

View The View menu allows you to move quickly between interfaces without using the icon buttons on the App Mode toolbar. It also allows you to access the Bar Code Dialog.

Bar Code Dialog

In the Bar Code Dialog you can create symbols by typing the text you wish to encode. This is a useful tool for creating configuration symbols, allowing you to configure your reader by reading the symbols you create.

Drag specific configuration values from the control tree directly into this field to encode new symbols. Choose a spatial orientation for the new symbol. Set a humanreadable caption for the symbol that matches the encoded data, or write your own caption.

The symbol you create will be displayed in the field at the bottom of the Bar Code Dialog.

MS-4 Imager User Manual

2-13

Page 40

Navigating in ESP

Navigating in ESP To change Imager settings, or to access the Utilities, Camera, Terminal, or Output Format views, click the App Mode button.

To return to EZ Mode, click the EZ Mode button.

To make changes to configuration settings in the control trees:

1. Left click on the + to expand menu items.

The X denotes the default option setting.

2. Double click the desired parameter and single click in the selection box to view options. 3. Place your cursor in the selection box, scroll down to the setting you want to change, and single click the setting. 4. Left click again on the open screen to complete the selection. 5. Right click on the open screen and select Save to Reader to implement the command in the Imager. You can send the command without saving it, or you can send and save the command simultaneously.

2-14

MS-4 Imager User Manual