Page 251

Camera and IP Setup

Window of Interest by ESP 1. From the Camera menu, click the WOI tab to bring up Window of Interest. If you haven’t already captured an image, click the Capture and Decode button to decode the present image. If successful, the Good Read indicator on the WOI tab will be green and the symbol will appear in the pane below. Note: You can resize the image by clicking and dragging the ESP window from the lower right corner. This is useful where very small symbols are being read. 2. Click and drag your cursor over the symbol that you want to isolate for reading. Notice that the surrounding area goes black. You can use the handles on the image area that you have just drawn to resize the region of interest. You can also click on the center of the window of interest and move it. 3. Test the new settings in Read Rate Mode.

Note: To remove the window of interest, click the Reset button or just click anywhere in the WOI pane. Note that all pixels not in the WOI are defined as black. Because the Imager has far less processing to do in a smaller window, read rates typically increase dramatically. One possible downside is that the chance of missing a symbol increases with the smaller window. Always verify that your WOI will be large enough to allow for any random movement of symbols in your field of view. MS-4 Imager User Manual

10-11

Page 252

Window of Interest

Window of Interest by Serial Command The exact size and position of the WOI within the image area can be defined numerically in terms of pixels. The figure to the right shows where to locate the start position of the row and column pointers and how to measure the column depth and row width dimensions.

WOI Row Pointer

WOI Column Pointer

WOI Row Depth

WOI Column Width

Top (Row Pointer) Definition: Serial Cmd: Default: Options:

Defines the row position of the upper-left starting point of the window. <K516,row pointer,column pointer,row depth,column width> 0 0 to 480

Left (Column Pointer) Definition: Serial Cmd: Default: Options:

Defines the column position of the upper-left starting point of the window. <K516,row pointer,column pointer,row depth,column width> 0 0 to 640

Height (Row Depth) Definition: Serial Cmd: Default: Options:

Defines the size, in rows, of the window. Maximum value is defined as the maximum row size of the image sensor minus the Top value. <K516,row pointer,column pointer,row depth,column width> 0 3 to (480 - row pointer)

Width (Column Width) Definition: Serial Cmd: Default: Options: 10-12

Defines the column position of the upper-left starting point of the window. <K516,row pointer,column pointer,row depth,column width> 0 8 to (640 - column pointer) MS-4 Imager User Manual

Page 253

Camera and IP Setup

Configuration Database The Configuration Database allows the user to manage multiple configuration profiles. It is a useful tool in applications that require several different complex Imager configurations to be applied sequentially, and it allows the user to perform far more complex operations than would be possible with only one set of configuration parameters. See Chapter 11, Configuration Database, for full documentation of this feature.

Configuration Database view, set for 5 Active Indexes, with Capture Settings highlighted.

MS-4 Imager User Manual

10-13

Page 254

Dynamic Setup

Dynamic Setup Dynamic Setup is used to calculate image capture timing during a read cycle. Without proper timing, the Imager will not be able to decode all symbols in a read cycle. An external trigger is used to activate image captures so the user can make timing adjustments as capture events occur.

The user can control Capture #, Number of Captures, and Number of Symbols using these spin boxes.

Read Rate is represented graphically in real-time as the user makes adjustments to the time delay between image captures.

The user can control Capture #, Number of Captures, and Number of Symbols using these controls.

The Delay Adjustment slider allows the user extremely precise control of the time delays between image captures in a read cycle. Delay values are shown in seconds in the field above the slider. The Coarse and Fine Delay Adjustment options determine whether larger or smaller adjustment increments will be used.

10-14

MS-4 Imager User Manual

Page 255

Camera and IP Setup

Pixel Sub-Sampling Definition: Usage: Default: Options:

The camera can be enabled to sub-sample pixels in the specified image frame. Sub-sampling can be set to either 4:1 or 16:1. These ratios signify the sampling rate. <K542,sub-sampling> Disabled 0 = Disabled 1 = 4:1 2 = 16:1

4:1 At this sampling rate, 1 pixel is output for every 4 pixels sampled. The image will be sampled 2:1 vertically and 2:1 horizontally, for a combined 4:1 ratio. An image with dimensions of 640 x 480 will be scaled to 320 x 240.

16:1 At this sampling rate, 1 pixel is output for every 16 pixels sampled. The image will be sampled 4:1 vertically and 4:1 horizontally, for a combined 16:1 ratio. An image with dimensions of 640 x 480 will be scaled to 160 x 120.

MS-4 Imager User Manual

10-15

Page 256

Camera

Camera Camera parameters are typically obtained during the calibration process, and do not necessarily need to be modified directly by the user.

Optics The MS-4 Imager has two different optical configurations available: Standard Density and Low Density. Determine the optics of your Imager and find the corresponding camera values in the following sections.

MS-4 Standard Density (HD 1.0 mm Optics), 3” Focal Distance Shutter Speed Usage: Definition:

Serial Cmd: Default: Options:

Faster shutter speeds reduce blurring in faster applications. Slower shutter speeds are useful in slower applications and lower contrast applications. This value sets the exposure or integration time for the image sensor pixels. The shutter speed setting in relation to the speed of the object is critical. If a slow shutter speed is selected to capture fast-moving objects, blurring or smearing of the image will occur. As shutter speed is increased, more light and gain become necessary, because the pixels’ exposure time has decreased. <K541,shutter speed,gain> 30 (1/30 second) 15 to 12,500

Gain Usage: Definition:

Serial Cmd: Default: Options:

10-16

Can be used to adjust pixel grayscale values for readability. Sets the gain value for the image sensor. This setting can be configured through autocalibration, which is the recommended method. A higher gain value will increase the brightness of the image, but the visual noise reduction performance of the system is reduced. Before configuring gain settings, the desired shutter speed should already be set and the gain should be configured to optimize the shutter speed setting. <K541,shutter speed,gain> 20 0 to 48

MS-4 Imager User Manual

Page 257

Camera and IP Setup

MS-4 Low Density (SD Optics), 4” Focal Distance Shutter Speed Usage: Definition:

Serial Cmd: Default: Options:

Faster shutter speeds reduce blurring in faster applications. Slower shutter speeds are useful in slower applications and lower contrast applications. This value sets the exposure or integration time for the image sensor pixels. The shutter speed setting in relation to the speed of the object is critical. If a slow shutter speed is selected to capture fast-moving objects, blurring or smearing of the image will occur. As shutter speed is increased, more light and gain become necessary, because the pixels’ exposure time has decreased. <K541,shutter speed,gain> 150 (1/150 second) 15 to 12,500

Gain Usage: Definition:

Serial Cmd: Default: Options:

Can be used to adjust pixel grayscale values for readability. Sets the gain value for the image sensor. This setting can be configured through autocalibration, which is the recommended method. A higher gain value will increase the brightness of the image, but the visual noise reduction performance of the system is reduced. Before configuring gain settings, the desired shutter speed should already be set and the gain should be configured to optimize the shutter speed setting. <K541,shutter speed,gain> 20 0 to 48

MS-4 Imager User Manual

10-17

Page 258

Focal Distance

Focal Distance Definition: Serial Cmd: Default: Options:

10-18

This command returns the Imager’s factory preset focal distance. <K525,focal distance (read only)> Standard Density = 300 (3”) Low Density = 400 (4”) N/A

MS-4 Imager User Manual

Page 259

Camera and IP Setup

Focal Distance Table (Read-Only) Number of Focal Distances Definition: Serial Cmd: Default: Options:

Specifies the number of focal distances supported by the Imager (1). <K526,number of focal distances,focal distance> 1 N/A (Focal Distance is factory preset.)

Focal Distance Definition: Serial Cmd: Default: Options:

Returns the Imager’s factory preset focal distance. <K526,number of focal distances,focal distance> Returns the Imager’s factory preset Focal Distance value. N/A

MS-4 Imager User Manual

10-19

Page 260

IP Threshold

IP Threshold Threshold Mode Fixed Mode works best when decode time must be as short as possible and the reflectance and illumination of the symbol area is uniform and unchanging. Cycle Fixed Mode is useful in applications where decode time can be slightly longer, and reflectance and illumination of the symbol area is uniform and unchanging. Otherwise, Adaptive Mode is the preferred mode. This value switches the image processing threshold mode between the Adaptive, Fixed, and Cycle Fixed modes. An adaptive routine sets the light/dark threshold using data acquired from the current read. A fixed routine applies the same gray scale threshold value to each and every symbol. A cycle fixed routine loops through a pre-defined range of values (Cycle Min to Cycle Max) by pre-defined increments (Cycle Step). <K512,threshold mode,threshold value,cycle min,cycle max,cycle step> Adaptive 0 = Adaptive 1 = Fixed 2 = Cycle Fixed

Usage:

Definition:

Serial Cmd: Default: Options:

Threshold Value A higher value will increase the threshold for distinguishing between light and dark elements. Determines how the Imager will distinguish light pixels from dark pixels. This value is used for Fixed Mode only. When Adaptive Mode is set, this value is ignored. <K512,threshold mode,threshold value,cycle min,cycle max,cycle step> 128 0 to 255

Usage: Definition: Serial Cmd: Default: Options:

Cycle Min Definition: Serial Cmd: Default: Options:

10-20

Starting value of the cycle mode. <K512,threshold mode,threshold value,cycle min,cycle max,cycle step> 0 0 to 255 Important: Cycle Min must be a smaller numerical value than Cycle Max.