Page 241

10 Camera and IP Setup Contents Camera and IP Setup by ESP .................................................................................................... 10-2 Camera and IP Setup Serial Commands.................................................................................... 10-3 Video........................................................................................................................................... 10-4 Evaluation ................................................................................................................................... 10-5 Calibration................................................................................................................................... 10-9 Window of Interest .................................................................................................................... 10-10 Configuration Database ............................................................................................................ 10-13 Dynamic Setup ......................................................................................................................... 10-14 Pixel Sub-Sampling .................................................................................................................. 10-15 Camera ..................................................................................................................................... 10-16 Focal Distance .......................................................................................................................... 10-18 Focal Distance Table (Read-Only) ........................................................................................... 10-19 IP Threshold ............................................................................................................................. 10-20 Number of Symbols in Field of View......................................................................................... 10-22 Image Processing Timeout ....................................................................................................... 10-23 Damaged Symbol ..................................................................................................................... 10-24 IP Mode .................................................................................................................................... 10-25 Hollow Mode ............................................................................................................................. 10-26 Mirrored Image ......................................................................................................................... 10-27 Illumination Brightness.............................................................................................................. 10-28 Skew Correction ....................................................................................................................... 10-29

This section provides adjustment parameters for the physical controls of the camera, image acquisition, database settings, and image diagnostics.

MS-4 Imager User Manual

10-1

Page 242

Camera and IP Setup by ESP

Camera and IP Setup by ESP

Click this button to bring up the Camera Setup menu.

To change a setting, double-click the setting and use your cursor to scroll through the options.

To open nested options, single-click the +.

10-2

MS-4 Imager User Manual

Page 243

Camera and IP Setup

Camera and IP Setup Serial Commands IP Threshold <K512,threshold mode,fixed threshold value> Mirrored Image <K514,mirrored image> Window of Interest <K516,row pointer,column pointer,row depth,column width> Hollow Mode <K517,hollow mode status> Number of Symbols in Field of View <K518,number of symbols in field of view> Damaged Symbol <K519,damaged symbol status> Focal Distance <K525,focal distance (read only)> Focal Distance Table <K526,number of focal distances,focal distance> IP Mode <K527,IP Mode,FLM direction> Illumination Brightness <K536,brightness> Skew Correction <K537,line speed,symbol direction> Camera <K541,shutter speed,gain> Pixel Sub-Sampling <K542,sub-sampling>

MS-4 Imager User Manual

10-3

Page 244

Video

Video The Video view is similar to the EZ Mode interface, in that the user has the ability to perform the same Locate, Calibrate, and Test routines. There is also a focal distance adjustment tool to the right of the video view. Video also features Capture and Decode functionality, which is similar to the Configuration interfaces (Communication, Read Cycle, Symbologies, I/O, Matchcode, and Diagnostics).

Initiates Calibration routine.

Activates the Imager’s target pattern and initiates live video display of the symbol in the field of view.

Allows the user to take an image capture of the symbol in the field of view at any time, and to decode the symbol data. Similar to the Capture and Decode function in the Configuration views.

Initiates the Test routine. Allows the user to test the Imager’s read rate and decodes per second, and also displays decoded symbol data in the field at the bottom of the screen, Click Stop to end the Test routine.

When enabled, shows the symbol in higher contrast than the default contrast value.

Symbol data and Test results are shown in this field.

10-4

MS-4 Imager User Manual

Page 245

Camera and IP Setup

Evaluation In Evaluation, you can view images currently in the Imager, capture and decode a symbol, save it as a digital file, and perform histogram and line scan evaluations. When you click on the Evaluation tab, you will see the images that are currently stored in the Imager. Click Receive to refresh this view. Click Capture/Decode to display the current stored image. Only one capture and decode event will occur, regardless of read cycle settings. Click Read to trigger a read cycle. If there is enough time in the read cycle, up to 32 good reads (or 6 full-scale images) can be captured and displayed, depending on the size of the images, and depending on the number enabled in Number of Captures under Capture Mode in the Camera Setup menu tree to the left of the tabs. If you click Save, the current image will be saved to the location of your choice. Note: An image can only be saved in the format in which it was uploaded to ESP. JPEG images will be saved as .jpg, and bitmaps will be saved as .bmp. When you click the JPEG Image box, notice that the Line Scan button is grayed out. The JPEG option allows faster captures and transfers, but since the JPEG standard compresses image data, it is not suitable for the more rigorous demands of line scan evaluation. JPEG also allows you to adjust the image quality (resolution) by adjusting the sliding tab between 1 and 100, 1 being the lowest quality and 100 being the highest. When possible, use the highest quality; when image transfer speed must be increased, use a lower image quality setting. Adjustments for this setting will depend on your specific hardware and software limitations.

MS-4 Imager User Manual

10-5

Page 246

Evaluation

Histogram Usage: Definition:

Useful in determining quality and contrast of symbols. A histogram is a graphic representation of the numeric count of the occurrence of each intensity (gray level) in an image. The horizontal axis represents the values of gray levels, and the vertical axis represents the number of pixels for each gray level.

Note: Since histograms are performed in the Imager, the results will be saved regardless of whether the image was uploaded as a JPEG (.jpg) or a bitmap (.bmp). 1. From the Evaluation window, click the Histogram button. The current image is transferred into the histogram operation. This may take a moment, since all the relevant pixels are being evaluated intensively. 2. When the Histogram window opens, you may need to expand the window and/or adjust the scroll bars in order to bring the image into view. 3. To generate a histogram, click and drag your cursor diagonally across the symbol or a portion of the symbol. The image will be surrounded by an “area of interest box”, a dashed blue line with red anchor points that can be selected and moved by placing a cursor inside the box, and can be resized by clicking and dragging the anchor points.

10-6

MS-4 Imager User Manual

Page 247

Camera and IP Setup

Threshold (Histogram) Enable Autothreshold is checked by default. To adjust the threshold manually, 1. Uncheck the Enable Autothreshold box. 2. Move the threshold marker (vertical green dashed line) in the Histogram chart. Hint: This should be midway between the maximum and minimum curves. 3. Click on the Send Threshold button to adopt the new threshold position.

MS-4 Imager User Manual

10-7

Page 248

Evaluation

Line Scan 1. From the Evaluation tab, click the Line Scan button. 2. Drag your cursor horizontally across the image. This will create a dashed horizontal line. Pixel information and a visual representation of the dark and light pixels will be displayed below the image.

When you center your cursor over the dashed line, it becomes a double arrow cross. This allows you to move the line anywhere in the window. You can also use your keyboard arrows to move the line incrementally in any direction. As with the histogram, the line scan compares light and dark pixels, but in a spatial distribution. On the Y axis of the graph below, 0 is black and 255 is white; the X axis represents the horizontal axis of the symbol as described by the line scan. When you click anywhere on the graph, a vertical red line appears at that point and its position and value (in terms of black-to-white) are updated in the Pixel Info table to the left of the graph (237 in this example). In addition, a horizontal dashed red line is displayed that indicates the average value.

10-8

MS-4 Imager User Manual

Page 249

Camera and IP Setup

Calibration The Calibration interface in ESP is a powerful and intuitive way to optimize the Imager’s performance. It allows the user to control several complex, simultaneous calibration operations, and to follow the progress of those operations using cues such as progress bars, real-time representations of calibration values, and other dynamic user feedback. See Chapter 4, Calibration, for full documentation of this feature.

ESP’s Calibration interface shown during a calibration routine

MS-4 Imager User Manual

ESP’s Calibration interface shown after a calibration routine

10-9

Page 250

Window of Interest

Window of Interest The active pixel area of the image sensor is called the Window of Interest (WOI). The WOI allows the user to select an area of the field of view in which the desired symbol is located. The programmable window of interest increases decode speed, improves threshold, and makes it easy to select specific symbols from among several in the field of view. The user provides the upper-left pixel location and the size of the window to define the Window of Interest.

Caution: Window of Interest will shrink the field of view and therefore could cause symbols to be missed in dynamic applications.

10-10

MS-4 Imager User Manual