Page 91

Calibration

Calibration Progress Indicators

During the calibration process, the Imager has a number of ways to communicate its progress to the user. The following three types of feedback are the primary ways that the Imager communicates calibration progress.

Read Rate LEDs

When calibration is initiated through a serial command or the EZ button, the Imager’s read rate LEDs indicate calibration progress as follows: LEDs 20% 20%, 40%, 60% 20%, 40%, 60%, 80% 20%, 40%, 60%, 80%, 100%

Calibration Progress Search Pass in progress. Medium Pass in progress. Fine-Tune Pass in progress. Calibrated Successfully (holds for green flash duration).

Beeper / Green Flash The beeper and green LED flash are used to indicate calibration status as shown in the table below: Indicator 2 quick beeps 5 quick beeps 1 long beep 1 sec. Green Flash

MS-4 Imager User Manual

Status Calibration has started. Calibration has failed. Calibration has been completed successfully. Calibration has been completed successfully.

4-13

Page 92

Initiating Calibration

Calibration Progress Output to Terminal

When initiated by serial command or EZ button, the autocalibration operation will output progress and process information to a terminal if the system is configured to do so.

Terminal Depending upon how the calibration options are configured, the autocalibration process can have up to 3 steps (Search Pass, Medium Pass, Fine-Tune Pass). Calibration data is shown in a simple table format under 7 category headings, each of which are defined below. Heading Prog Rating Decode Quality Shutter Gain Locate

Definition Progress indicator with a range of 0 - 100. Indicates percent complete. Rating indicator; higher ratings are more favorable. Number of successful decodes for the pass. Quality indicator; higher ratings are more favorable. Shutter setting under operation. Gain setting under operation. Time required to locate symbol, expressed in milliseconds.

Calibration Progress Output Examples (Terminal) Search Pass

The purpose of Search Pass is to decode a symbol in as few configurations as possible during calibration. This process is designed to quickly identify symbology type, and any image processing parameters that are already calibrated. Running Search Pass

4-14

Prog

Rating

Decode

Quality

Shutter

Gain

Locate

12 14 16 18

0 0 0 2174

0 0 0 1

0 0 0 72

250 250 250 250

0 9 18 27

0 0 0 24

MS-4 Imager User Manual

Page 93

Calibration

Medium Pass

The theory behind Medium Pass is to develop a readable range from which to dial in a decoded symbol. Running Medium Pass Prog

Rating

Decode

Quality

Shutter

Gain

Locate

51 53 55 57 59 61 63 65 67 69 71 73 75

4216 8436 6336 8448 8456 8464 8472 8488 8504 8512 8528 8584 8644

2 4 3 4 4 4 4 4 4 4 4 4 4

8 20 24 32 40 48 56 72 88 96 112 168 228

250 250 250 250 250 250 250 250 250 250 250 250 250

0 4 8 12 16 20 24 28 32 36 40 44 48

5 4 4 4 5 4 5 5 5 5 6 5 5

Rating List (Best): Rating = 8606; Shutter = 250; Gain = 48 Rating = 8581; Shutter = 250; Gain = 44 Rating = 8553; Shutter = 250; Gain = 40 Rating = 8527; Shutter = 250; Gain = 36 Rating = 8505; Shutter = 250; Gain = 32 Rating = 8488; Shutter = 250; Gain = 28 Rating = 8476; Shutter = 250; Gain = 24

MS-4 Imager User Manual

4-15

Page 94

Initiating Calibration

Fine-Tune Pass

The theory behind Fine-Tune Pass is to dial in a decoded symbol based on the range supplied by the Medium Pass. Running Fine Tune Pass Prog

Rating

Decode

Quality

Shutter

Gain

Locate

77 79 81 84 86 88 90 93 95 97 100

6416 6424 6424 6432 6448 6464 6476 6488 6506 6524 6538

3 3 3 3 3 3 3 3 3 3 3

104 112 112 120 136 152 164 176 194 212 226

250 250 250 250 250 250 250 250 250 250 250

38 39 40 41 42 43 44 45 46 47 48

7 6 6 6 5 5 5 5 6 5 6

Rating List (Best): Rating = 6527; Shutter = 250; Gain = 48 Rating = 6517; Shutter = 250; Gain = 47 Rating = 6505; Shutter = 250; Gain = 46 Rating = 6491; Shutter = 250; Gain = 45 Rating = 6476; Shutter = 250; Gain = 44 Rating = 6462; Shutter = 250; Gain = 43 Rating = 6449; Shutter = 250; Gain = 42 Calibration PASSED.

4-16

MS-4 Imager User Manual

Page 95

Calibration

Additional Notes about Calibration The following conditions apply to the Imager’s calibration process. Some of these items are noted at various points throughout this section, or in other sections of the Imager’s documentation. 1. The Mirrored Image parameter <K514> is not part of the calibration process. 2. Background Color <K451> is calibrated. 3. If Window of Interest (WOI) Framing is enabled, the WOI will be set to full frame when calibration begins. If WOI Framing is disabled, the current WOI configuration will be used for the Search Pass. 4. IP Mode <K527> will not be altered during calibration. 5. Threshold Mode <K512> will be set to Adaptive during calibration. At the end of a successful calibration, Threshold Mode will remain set to Adaptive regardless of its previous setting. Otherwise, the value will revert to its original state. 6. If Symbol Type is enabled for calibration (Autodiscriminate), then Interleaved 2 of 5 Range Mode Status (Interleaved 2 of 5) <K472> will be enabled. This allows variable-length Interleaved 2 of 5 symbols to be decoded. If an Interleaved 2 of 5 symbol is decoded during calibration, then symbol length # 1 will be set to the decoded symbol length at the end of calibration. Otherwise, the symbol lengths will be restored to their original configurations. 7. The symbol size, dimension, and orientation parameters of the No Symbol Message and Bad Symbol Message, and 2D Symbology Qualification command <K718> will be updated if calibration is completed successfully. 8. All symbol types that were enabled before calibration will still be enabled after calibration. For example, if Data Matrix ECC 200 was enabled before calibration, and the calibration routine was performed on a Code 128 symbol, then after calibration is completed both Data Matrix ECC 200 and Code 128 will be enabled. 9. The calibration process does not modify the global Composite status <K453>. The global Composite status must be configured properly before calibration. 10. If the user requires calibration of a stacked symbology <K482>, <K483>, or <K484>, that symbology must be enabled and configured appropriately before calibration. 11. UPC Supplementals will be disabled during calibration. 12. The Search Pass process will use the configurable Window of Interest for image captures. However, when the search process is completed, the WOI will be reduced to include only the symbol of interest and some additional boundary area.

MS-4 Imager User Manual

4-17

Page 96

Additional Notes about Calibration

4-18

MS-4 Imager User Manual

Page 97

5 Read Cycle Contents Read Cycle by ESP ...................................................................................................................... 5-2 Read Cycle Serial Commands...................................................................................................... 5-3 Read Cycle Setup......................................................................................................................... 5-4 Multisymbol................................................................................................................................... 5-5 Trigger Mode and Duration........................................................................................................... 5-6 External Trigger Polarity ............................................................................................................. 5-11 Serial Trigger .............................................................................................................................. 5-12 Start Trigger Character (Non-Delimited)..................................................................................... 5-13 Stop Trigger Character (Non-Delimited) ..................................................................................... 5-13 End of Read Cycle...................................................................................................................... 5-14 Capture Mode ............................................................................................................................. 5-16 Capture Timing ........................................................................................................................... 5-20 Image Processing Timeout ......................................................................................................... 5-22 Image Storage ............................................................................................................................ 5-23 Minimum Good Reads ................................................................................................................ 5-25 Setting Up the Imager for EZ Trax.............................................................................................. 5-26

After you’ve established communications and completed basic read rate testing, you will need to address the spatial and timing parameters associated with your application. This section explains those parameters.

MS-4 Imager User Manual

5-1

Page 98

Read Cycle by ESP

Read Cycle by ESP

Click this button to bring up the Read Cycle menu. To change a setting, double click the setting and use your cursor to scroll through the options.

To open nested options, single click the +.

5-2

MS-4 Imager User Manual

Page 99

Read Cycle

Read Cycle Serial Commands Trigger Mode/Duration Serial Trigger Character External Trigger State End of Read Cycle Minimum Good Reads Multisymbol Start Trigger Character Stop Trigger Character Capture Mode Capture Timing Image Storage IP Timeout

MS-4 Imager User Manual

<K200,trigger mode,trigger filter duration>

<K201,serial trigger character> <K202,external trigger state> <K220,end of read cycle,read cycle timeout> <K221,minimum good reads> <K222,number of symbols,multisymbol separator> <K229,start character> <K230,stop character> <K241,capture mode,number of captures,rapid capture mode> <K242,time before first capture,time between first and second captures,,,,,,,,time between seventh and eighth captures> <K244,image storage type,image store mode> <K245,image processing timeout>

5-3

Page 100

Read Cycle Setup

Read Cycle Setup Setting up read cycle and triggering parameters will involve a series of decisions based on your particular application, as follows: 1. Select the number of symbols to be read in a single cycle. The MS-4 can read multiple symbols in a single image frame. 2. Decide on the trigger type to be used: if serial, choose a serial character; if external, choose either Level or Edge. 3. Designate how the read cycle should end (Timeout, New Trigger, Last Frame). 4. Select Capture Mode, Continuous Mode, or Rapid Mode. 5. Select Number of Captures (if in Rapid Capture Mode). 6. Set the Time Before First Capture and Time Between Captures, if any. Note: The Imager’s camera captures images at a rate of about 16/second (based on a full-size 640 x 480 image). The capture rate increases as frame sizes decrease. Note: If you need to set up your MS-4 for use with EZ Trax software, see Setting Up the Imager for EZ Trax.

5-4

MS-4 Imager User Manual