Page 371

Appendices

Appendix J, Allen-Bradley Version 20 PLC Setup, Trigger and Read • To add a new EDS file to RSLogix 5000 Version 20 select the EDS Hardware Installation Tool from the menu item under Tools.

• Click the Next button.

MINI Hawk Xi High Performance Imager User Manual

A-47

Page 372

Allen-Bradley Version 20 PLC Setup, Trigger and Read • Make sure the Register an EDS File(s) radio button is selected, then click Next.

• Click the Browse button to locate the new EDS file on your PC. Then click Next.

A-48

MINI Hawk Xi High Performance Imager User Manual

Page 373

Appendices • Click the Next button.

• Click the Next button.

MINI Hawk Xi High Performance Imager User Manual

A-49

Page 374

Allen-Bradley Version 20 PLC Setup, Trigger and Read • Click the Next button.

• Click the Finish button.

A-50

MINI Hawk Xi High Performance Imager User Manual

Page 375

Appendices • Now the EDS file has been loaded into RSLogix’s database. Right-click the Ethernet menu item and select New Module.

• To find your camera in the list, type “fis” and the dialog will show only devices with the letters FIS in the name. Either double-click the camera you want or highlight it and click the Create button.

MINI Hawk Xi High Performance Imager User Manual

A-51

Page 376

Allen-Bradley Version 20 PLC Setup, Trigger and Read • Enter the name of the device used in the PLC program and the IP address of the camera.

• After the new device has been added to the project, the default assembly data will be the small size. You can change it to large by double-clicking the camera menu item in the tree control and clicking the Change button on the dialog.

A-52

MINI Hawk Xi High Performance Imager User Manual

Page 377

Appendices • Select the big assembly size if desired and click the OK button.

• Right-click the Add-On Instructions node in the tree view and select Import Add-On Instruction.

MINI Hawk Xi High Performance Imager User Manual

A-53

Page 378

Allen-Bradley Version 20 PLC Setup, Trigger and Read • Locate the AOI file on the PC. AOIs can be downloaded from the Microscan website. Choose the appropriate file based on the assembly size selected in the module definition.

• The next dialog will show the details of the AOI. Click the OK button to finish the import process.

A-54

MINI Hawk Xi High Performance Imager User Manual

Page 379

Appendices • Expand the MainProgram node under Tasks->MainTask. Double-click the MainRoutine node to open the ladder logic editor. Select the Add-On tab to add the new Add-On item. Click the AOI button and the new AOI will be added to the first rung.

• The first three elements of the AOI then need to be created. The last two need to be linked. Right-click in the first element and select New Tag on the popup menu.

MINI Hawk Xi High Performance Imager User Manual

A-55

Page 380

Allen-Bradley Version 20 PLC Setup, Trigger and Read • Enter a specific name for the AOI element and click the Create button when done. Repeat this step for the Assembly_Input and Assembly_Output.

• To link the connection input and outputs double-click the element and select the drop down button. Locate the device and expand :I for inputs. Double-click :I:Data to complete the link. Double-click the output connection and expand :O for outputs. Double-click :I:Data to complete the link.

A-56