Firmware Verification Request Part Number by ESP You can send a request to the imager for part numbers, checksums, boot code, and application code. 1. Click the Firmware tab. 2. From the pulldown selection box to the left of the Request Part No. button, make your selection. 3. Select the code type to see its part number displayed in the text field to the right of the Request Part No. button.
Request Part Number by Serial Command • When you send <#> (a request for all product part numbers), the imager returns: <#b/BOOT_P/N><#a/APP_P/N><#p/PROFILE_P/N>. • When you send <#a> (a request for the application code part number), the imager returns: <#a/APP_P/N>. • When you send <#b> (a request for the boot code part number), the imager returns: <#b/BOOT_P/N>. • When you send <#p> (a request for profile module part numbers), the imager returns: <#p/PROFILE_P/N>.
MINI Hawk Xi High Performance Imager User Manual
13-17
Page 302
Firmware
Request Checksum by ESP You can send a request to the imager for part numbers, checksums, boot code, and application code. 1. Click the Firmware tab. 2. From the pulldown selection box to the left of the Request Checksum button, make your selection. 3. Select the code type to see its checksum displayed in the text field to the right of the Request Checksum button.
Request Checksum by Serial Command • When you send <!> (a request for all available firmware checksums), the imager returns: <!b/BOOT_CHECKSUM><!a/APP_CHECKSUM><!p/PROFILE_CHECKSUM> • When you send <!a> (a request for the application code checksum), the imager returns: <!a/APP_CHECKSUM> • When you send <!b> (a request for the boot code checksum), the imager returns: <!b/BOOT_CHECKSUM> • When you send <!p> (a request for profile module checksum), the imager returns: <!p/PROFILE_CHECKSUM>
13-18
MINI Hawk Xi High Performance Imager User Manual
Page 303
Utilities
Default/Reset/Save Understanding and controlling your imager’s active, saved, and default settings is critical to its successful operation.
Saved for Power-on
Resets (not saved for power-on)
Function
Serial Cmd
ESP (first, right-click in any menu tree)a
EZ Button
<A>
Save to Reader, Send No Save
No
<Ard>
No
No
<Arp>
No
No
<Arc>
No
No
Reset Reset and Recall Microscan Defaults Reset and Recall Power-On Parameters Reset and Recall Customer Default Parameters
Save to Reader, Send and Save Save to Reader, Send and Save Customer Defaults for Power-Onb
Save Current Settings for Power-On
<Z>
Save Current Settings as Customer Default Parameters for Power-On
<Zc>
Recall Microscan Default Parameters and Save for Power-On
<Zrd>
No
No
Recall Customer Default Parameters and Save for Power-On
<Zrc>
No
Press and hold while powering on imager
No No a. When you right-click in a menu tree and select Default Current Menu Settings or Default All ESP Settings, it is important to note that only ESP settings are defaulted. To save these defaults to the reader itself, you need to follow up with a Save to Reader, Send and Save command. b. Only available in ESP if enabled under the Options pulldown menu.
Resets Resets (“A” commands) affect only the current settings (active memory) and are not saved for power-on.
Saved for Power-on Power-on parameters (“Z” commands) are saved to NOVRAM and recalled and loaded into current parameters when power is cycled to the imager or the <Arp> command is issued.
Defaults Defaults are Microscan firmware settings or saved customer settings that can be recalled, either by software or hardware reset.
MINI Hawk Xi High Performance Imager User Manual
13-19
Page 304
Default/Reset/Save
Customer Default Parameters Customer default parameters (saved by <Zc>) are the same set of parameters as power-on parameters but are saved in a different, isolated section of NOVRAM. This allows a user essentially to create a backup set of parameters that can be recalled in the event that the current parameters or power-on parameters have been accidentally changed or are no longer desired. It is important to note that a hardware default does not affect customer default parameters. For example, a user that has inadvertently changed communication settings and saved them with a <Z> command, may not know the correct settings or have the capability to communicate within those settings. By first doing an EZ button default or hardware default to restore the known Microscan defaults, the user can then recall the previous customersaved settings with an <Arc> or <Zrc> command.
Microscan Default Parameters Microscan default parameters are contained in the firmware and cannot be changed.
Software Defaults Microscan default parameters can be recalled (loaded into current settings) with <Ard> command or recalled and saved for power-on with the <Zrd> command.
Hardware Default If a software default and reset is not possible, it may be necessary to reset the reader by shorting (connecting) specific pins. This procedure has the same effect as the <Zrd> software command. Important: For this reset to occur, this command must be executed within 60 seconds of a power-on or a reset. 1. Apply power to the reader. 2. Locate Pin 3 (Default) and Pin 7 (Ground) on the M12 connector. (Access depends on wiring configuration. May require a QX-1 and accessory cable). Caution: Be certain that the correct pins are located. Connecting the wrong pins could cause serious damage to the unit. 3. Momentarily connect these wires (or pins) and listen for a series of short beeps. 4. Within 3 seconds, connect them again. A longer beep should be heard. If not, repeat the process.
Default on Power-On You can also use the EZ button to default the reader by holding it down while applying power to the reader, provided that this feature is enabled.
13-20
MINI Hawk Xi High Performance Imager User Manual
Page 305
Utilities
Imager Status Requests <?> Status Byte The imager responds to a status request <?> with a two character hex value, such as <?/22>. To determine status: 1. Look up the binary conversion in the table below. For example, the first hex 2 would be 0 0 1 0 in binary, as read from binary digits 3 through 0; the second hex 2 is also 0 0 1 0 as read from binary digits 7 through 4. 2. Next, enter your binary values from the table below in the “Binary” column next to the appropriate bit. Binary Bit 0 1 2 3 4 5
Binary 0 1 0 0 0 1
Imager Status Command error detected Command received Communication error detected Flash sector unprotect failure Host port buffer overflow Imager is in a read cycle
3. Under “Binary,” interpret 1s as true and 0s as not true. For example, bit 1 has a 1 in the “Binary” column, indicating “Command Received”. Bit 5 is also a 1, indicating that the “Imager is in a read cycle”.
<K?> All Status Request
Hex Value 0 1 2 3 4 5 6 7 8 9 A B C D E F
Bit Digits 7
6
5
4
3
2
1
0
0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1
0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1
0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1
This is the fastest way to learn the imager’s current configuration. Sending this request will return the current settings of all commands, starting with the lowest K command value and ending with the highest K command value.
<K??> All Descriptor Status Request This request will return all current descriptors for every K command, starting with the lowest K command value and ending with the highest K command value.
<K?#> All Range Status Request This request will return the current settings of all commands within the user-defined range, starting with the lowest user-defined K command value and ending with the highest user-defined K command value.
MINI Hawk Xi High Performance Imager User Manual
13-21
Page 306
Imager Status Requests
<Knnn?> Single Status Request This request will return the value of the variables associated with the requested K command. The request of a single entry of a database command cannot exceed the number of database slots for the specific command.
<Knnn??> Single Descriptor Status Request This request returns the basic functional description of all fields in the requested K command.
<Knnn?#> Single Range Status Request This request will return the value range and storage type description of all fields in the requested K command.
<Knnn?*> Display Command Wildcard This request will return the individual K command status, description, and range for each parameter.
13-22
MINI Hawk Xi High Performance Imager User Manual
Page 307
Utilities
Learn Operations Learn Sending the <LEARN> command from ESP’s Terminal will put the imager into a mode of operation that will cause it to “learn” the next Data Matrix symbol decoded. This mode of operation will remain active until either a Data Matrix symbol is decoded or the call is made to disable the mode and revert back to normal operation. Upon decoding a Data Matrix symbol, the image processing will save pertinent information regarding the target symbol to allow it to be processed more quickly and consistently. The data collected by the Learn operation can be saved for a Power-On condition by sending the <Z> command.
Unlearn Sending the <UNLEARN> command will cause the imager to discard any information acquired during a Learn operation. The Unlearn state can be saved for a Power-On condition by sending the <Z> command.
Learn Status Sending the <LEARN?> request will return the current status of Learn operations. Responses are sent in this format: <LEARN,0> (Default; symbol has not been learned.) <LEARN,1> (Learn operation in progress.) <LEARN,2> (Symbol has been learned.)
Learn Persistence The learn state and parameters persist in the same way as ordinary parameters. Examples: • A MINI Hawk Xi in a Learned state has not been saved. Cycling power will remove any Learned state information and the imager will power-on in its configured state. • A MINI Hawk Xi is saved in a Learning state. The imager will power-on in the Learning state and will learn the first Data Matrix symbol decoded. • A MINI Hawk Xi is saved in a Learned state. The imager will power-on in the Learned state and will only decode the learned symbol type. • A MINI Hawk Xi in a Learned state is issued a reset default command <Ard>. The unit will return to an Unlearned state but if power is cycled it will return to its saved state.
MINI Hawk Xi High Performance Imager User Manual
13-23
Page 308
Other Operational Serial Commands
Other Operational Serial Commands The following serial utility commands can be entered from ESP’s Terminal or a PLC:
Y-Modem Upload Transfer Options <uy,path,filename>
Y-Modem Download Transfer Options See MINI Hawk Xi Image Output for an explanation of how to use this feature. <dy,path,filename>
Image Library Request <op,9> Manages files in a selected directory. File Source (Nothing) / /saved *.* /del /saved/del del*.*
13-24
Explanation All files in “root” directory All files in “root” directory All files in “saved” directory All files in all directories Deletes all files in the root director Deletes all files in the saved directory Deletes files in all directories
MINI Hawk Xi High Performance Imager User Manual
Page 309
Utilities
Bar Code Configuration Mode Definition: Serial Cmd:
Bar Code Configuration Mode is a way of programming the imager by using ECC 200 Data Matrix symbols. <BCCFG>
Bar Code Configuration Mode can be entered three different ways: 1. By forcing the imager into Bar Code Configuration Mode by serial command <BCCFG>. 2. By configuring one of the 4 EZ Button positions to Bar Code Configuration Mode. 3. By reading a Data Matrix symbol with a special code word used by ISO/IEC 16022 to signify imager programming. This can be either in a regular read cycle or during a read rate test. Reading this symbol in the calibration routine will have no effect.1 Once Bar Code Configuration Mode has been entered, the Data Matrix symbols can be thought of as serial data. You can configure the imager by printing labels in Microscan’s serial command format. Commands are processed as if the data were streamed in through the serial port. The imager will acknowledge the symbol with a beep, green flash, and echo the serial data to the host. If the command causes the imager to produce more serial output, such as serial verification or counter requests, the data will be routed to the host port. Bar Code Configuration Mode can be exited by any reset <A> or <Z> command as well as a <J> or a quick press and release of the EZ Button. The command to exit Bar Code Configuration Mode can be included as part of the Data Matrix symbol. For example, try encoding <K200,4><K220,1><J> into a Data Matrix symbol. This configures the imager to enable Serial Trigger Mode, to program a new trigger to end the read cycle, and to exit Bar Code Configuration Mode with <J>. To end all EZ Button functions, press the EZ Button once and quickly release.
1. In normal reading modes, it is required to read a special Data Matrix symbol with a special codeword used by ISO/IEC 16022 to signify imager programming.
MINI Hawk Xi High Performance Imager User Manual
13-25
Page 310
Other Operational Serial Commands
13-26