Page 281

Terminal

Find The Find function allows you to enter text strings to be searched for in the Terminal window. For example, a series of symbols have been scanned into the Terminal view and you want to determine if a particular symbol whose data begins with “ABC” has been read. 1. Type “ABC” into the Find box.

2. Press Enter. The first instance of “ABC” will be highlighted in the Terminal window. 3. Click the Find button to the left of the text field to locate additional instances of “ABC”.

MINI Hawk Xi High Performance Imager User Manual

12-3

Page 282

Send

Send The Send function allows you to enter serial commands and then send them to the imager. 1. Type the command into the Send box.

2. Press Enter. 3. Click the Send button to the left of the text field to send .

12-4

MINI Hawk Xi High Performance Imager User Manual

Page 283

Terminal

Macros Macros can be stored in a macro selection bar, edited in a separate window, and executed by clicking on the macro name.

Click on Next Row to see the next row of macros

Click on the first arrow here to see Add Macro or Default Macros. When macros are defaulted, the entire macro set is restored to the original macro commands.

Click on subsequent arrows to edit macros.

When you click on the macro name, the macro is executed in the Terminal window. If this is a command, it is sent to the reader at the same time that it is displayed.

Editing a Macro When you click the arrow next to any macro and select Edit, the following appears:

You can edit an existing macro or type in the Macro Name text field and define it in the Macro Value text field. Click OK.

MINI Hawk Xi High Performance Imager User Manual

12-5

Page 284

Terminal Window Menus

Terminal Window Menus Right-click on the Terminal window to display the following menu: • Copy selected text to clipboard. • Paste from Terminal or other text. • Clear all text in Terminal window. • Select All text in the Terminal window. • Save... brings up a Save As dialog. • Change Font... of text in Terminal; brings up a Font dialog. • Change Echo Font... to change typed text; brings up a Font dialog. • Enable Echo enables Echo text (typed by user). • Change Background Color of Terminal window. • Non-Printable Characters allows you to hide non-printable characters, or to show them in Standard or Enhanced format. • Default Settings returns all the above settings to default. • Keyboard Macros allows you to create new keyboard macro commands that can be sent from function keys (F2, F4, F5, etc.)

Terminal Dropdown Menu The dropdown Terminal menu has Capture Text, Save Current Text, Send File, Find Next, and Find Previous functions, as well as the same functions defined above. • Capture Text... lets you append data in real time to a text file of your choice. While in operation, the text file cannot be opened. You can select Pause to interrupt the capture flow or Stop to end the flow and open the file. • Save Current Text... saves all text in the Terminal window to a text file. • Send File allows you to browse for specific files and send them to the reader. • Find Next searches for a user-defined section of text in the Terminal. • Find Previous operates in the same way as Find Next, but searches backward through Terminal text.

12-6

MINI Hawk Xi High Performance Imager User Manual

Page 285

13 Utilities Contents Serial Utility Commands ............................................................................................................. 13-2 Read Rate .................................................................................................................................. 13-4 Counters ..................................................................................................................................... 13-6 Device Control ............................................................................................................................ 13-8 Differences from Default............................................................................................................. 13-9 Master Database ...................................................................................................................... 13-10 Firmware................................................................................................................................... 13-16 Default/Reset/Save................................................................................................................... 13-19 Imager Status Requests ........................................................................................................... 13-21 Learn Operations...................................................................................................................... 13-23 Other Operational Serial Commands ....................................................................................... 13-24

Utility commands are generally commands that are performed during imager operations to check or determine read rates, or to perform miscellaneous operations on imager hardware. Serial utility commands are not prefaced with a “K” and a numeric code, nor do they require an initialization command (<A> and <Z>). They can be entered from within any terminal program or from ESP’s Terminal or Utilities windows.

MINI Hawk Xi High Performance Imager User Manual

13-1

Page 286

Serial Utility Commands

Serial Utility Commands Note: For a list of all K commands, see Serial Configuration Commands. Type Read Rate

Counter Request and Clear

Master Database

Part Number / Checksum

Device Control

Default/Reset/Save

13-2

Command <C> <Cp> <J> <N> <O> <T> <U> <V> <W> <X> <Y> <G> <Gn> <NEWM> <#> <#a> <#b> <#p> <!> <!a> <!b> <!p> <L1> <L2> <L3> <I1> <I0> <I> <H> <a1> <A> <Ard> <Arp> <Arc> <Z>

Name Enter Decode Rate Test Enter Percent Rate Test Exit Decode Rate and Percent Rate Test No Read Counter No Read Counter Reset Trigger Counter Trigger Counter Reset Good Read/Match Counter Good Read/Match Counter Reset Mismatch Counter Mismatch Counter Reset Store Next Symbol Read to Database Index 1 Store Next Symbol Read to Database Index n New Master Load Status Display All Firmware Part Numbers Display Application Code Part Number Display Boot Code Part Number Display Profile Module Part Numbers Display All Available Firmware Checksums Display Application Code Code Checksum Display Boot Code Checksum Display Profile Module Checksum Programmable Output 1 Programmable Output 2 Programmable Output 3 Targeting System On Targeting System Off Disable Imager Enable Imager Include PDF Information in Preamble (PDF417) Reset (does not save for power-on) Reset and Recall Microscan Defaults Reset and Recall Power-On Parameters Reset and Recall Customer Default Parameters Save Current Settings for Power-On MINI Hawk Xi High Performance Imager User Manual

Page 287

Utilities <Zc> Default/Reset/Save

<Zrd> <Zrc>

Imager Status Request Commands

Learn

Other Operational Commands

<?> <K?> <K??> <K?#> <Knnn?> <Knnn??> <Knnn?#> <LEARN> <UNLEARN> <LEARN?> <uy,path,filename> <dy,path,filename> <op,9> <@CAL> <BCCFG> <VAL>

MINI Hawk Xi High Performance Imager User Manual

Save Current Settings as Customer Default Parameters for Power-On Recall Microscan Default Parameters and Save for Power-On Recall Customer Default Parameters and Save for Power-On Imager Status Byte All Status Request All Descriptor Status Request All Range Status Request Single Status Request Single Descriptor Status Request Single Range Status Request Initiate Learn Operation Initiate Unlearn Operation Display Learn Status Y-Modem Upload Transfer Options Y-Modem Download Transfer Options Image Library Request Autocalibrate Enter Bar Code Configuration Static Validation

13-3

Page 288

Read Rate

Read Rate Click the Utilities button and then the Read Rate tab to display the Read Rate view.

To see the number of decodes per second, click the Decodes/sec radio button and then the Start button. To see the percentage of decodes, click the Percent radio button and then the Start button. Read Rate information is displayed in the lower portion of the Utilities view. Serial commands can also be sent to the imager from this screen.

13-4

To end a Read Rate test, click the Stop button (the Start button becomes a Stop button during an active Read Rate test.)

MINI Hawk Xi High Performance Imager User Manual

Page 289

Utilities

Read Rate Serial Utility Commands Enter Decodes/Second Test Sending <C> instructs the imager to transmit the decodes per second and symbol data (if any). The decode rate can vary dramatically due to the angle and location of the symbol in relation to the field of view. This test is very useful in aligning and positioning the imager during setup.

Enter Percent Test Sending <Cp> instructs the imager to transmit the percentage of decodes and any decoded symbol data.

End Read Rate Test Sending <J> ends both the Percent test and the Decodes/Second test.

MINI Hawk Xi High Performance Imager User Manual

13-5

Page 290

Counters

Counters Click the Utilities button and then the Counters tab to display the Counters view.

Counter commands can be a numeric value from 00000 to 65535. After reaching the maximum numeric limit of 65535, an error message will be displayed and the counter will automatically roll over and start counting again at 00000. To obtain the cumulative total of counts after the rollover has occurred, add 65536 per each rollover (the imager does not keep track of the number of rollovers) to the current count. Note: All counter values will be lost if power is cycled, or if the imager receives a Reset or Save command. Click the Request button to display the appropriate count or Clear to set the counter to zero.

Trigger, Good Read, No Read, and Mismatch counters can be requested and cleared simultaneously (Request All and Clear All buttons) or individually (Request and Clear buttons to the left of each item).

13-6