The text of a manual · part 22 of 39
MINI Hawk Xi High Performance Imager User Manual, pages 211 to 220
Pages 211 to 220 of 388
The original document is the PDF (6.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan Mini Hawk Xi
Page 211
Symbol Quality
Data Matrix Output Mode Note: Output Mode applies to ISO/IEC 16022 symbol quality parameters. Definition: Serial Cmd: Default: Options:
Output Mode specifies how the four output parameters, if enabled, are formatted. <K708,symbol quality separator,output mode> Grade 0 = Grade 1 = Value
Grade If in Grade Mode, a grade (A,B,C,D) is appended to the symbol data.
Value If in Value Mode, the calculated value for the given parameter is appended to the symbol data.
MINI Hawk Xi High Performance Imager User Manual
8-9
Page 212
ISO/IEC 16022 Symbol Quality Output
ISO/IEC 16022 Symbol Quality Output Symbol Quality Parameters for Data Matrix symbols specified by ISO/IEC 16022.
Symbol Contrast Usage: Definition:
Serial Cmd: Default: Options:
Lets the user know if contrast settings are less than acceptable. All the pixels that fall within the area of the test symbol, including its required zone, will be sorted by their reflectance values to select the darkest 10% and the lightest 10% of the pixels. The arithmetic mean of the darkest and the lightest pixels is calculated and the difference of the two means is the Symbol Contrast. (ANSI) Symbol Contrast grading is defined this way: A (4.0) if SC > 70% B (3.0) if SC > 55% C (2.0) if SC > 40% D (1.0) if SC > 20% F (0.0) if SC < 20% If enabled, the symbol contrast is appended to the symbol data according to the ISO/IEC 16022 Symbol Quality Output Mode setting. <K709,symbol contrast,print growth,axial non-uniformity,UEC> Disabled 0 = Disabled 1 = Enabled
Print Growth Definition:
Serial Cmd: Default: Options:
8-10
The extent to which dark or light markings appropriately fill or exceed their module boundaries. These values are determined by counting pixels in the clock pattern of the binary digitized image, then comparing it to a nominal value and minimum and maximum values. The print growth grade is defined in this way: A (4.0) if -.050 < PG < 0.50 B (3.0) if -.070 < PG < 0.70 C (2.0) if -.085 < PG < 0.85 D (1.0) if -.10 < PG < 1.00 F (0.0) if PG < -1.00 or PG > 1.00 If enabled, the print growth is appended to the symbol data according to the ISO/IEC 16022 Symbol Quality Output Mode setting. <K709,symbol contrast,print growth,axial non-uniformity,UEC> Disabled 0 = Disabled 1 = Enabled
MINI Hawk Xi High Performance Imager User Manual
Page 213
Symbol Quality
Axial Non-Uniformity (Data Matrix Only) Definition:
Serial Cmd: Default: Options:
Axial non-uniformity is a measure of how much the sampling point spacing differs from one axis to another, namely AN = abs (XAVG YAVG) / ((XAVG + YAVG)/2) where abs () yields the absolute value. If a symbology has more than two major axes, then AN is computed for those two average spacings which differ the most. (ANSI) axial non-uniformity grading is defined this way: A (4.0) if AN < .06 B (2.0) if AN < .08 C (2.0) if AN < .10 D (1.0) if AN < .12 F (0.0) if AN > .12 If enabled, the axial non-uniformity is appended to the symbol data according the ISO/IEC 16022 Symbol Quality Output Mode setting. <K709,symbol contrast,print growth,axial non-uniformity,UEC> Disabled 0 = Disabled 1 = Enabled
Unused Error Correction (Data Matrix Only) Definition:
Serial Cmd: Default: Options:
The correction capacity of Reed-Solomon decoding is expressed in the equation: e + 2d < d - p, where e is the number of erasures, d is the number of error correction code words, and p is the number of code words reserved for error detection. A (4.0) if UEC > .62 B (3.0) if UEC > .50 C (2.0) if UEC > .37 D (1.0) if UEC > .25 F (0.0) if UEC < .25 If enabled, the UEC is appended to the symbol data according to the ISO/IEC 16022 Symbol Quality Output Mode setting. <K709,symbol contrast,print growth,axial non-uniformity,UEC> Disabled 0 = Disabled 1 = Enabled
MINI Hawk Xi High Performance Imager User Manual
8-11
Page 214
ISO/IEC 16022 Symbol Quality Output by ESP
ISO/IEC 16022 Symbol Quality Output by ESP ESP’s Symbol Quality interface allows you to evaluate Data Matrix symbols for compliance with ISO/IEC 16022 requirements. First, determine which ISO/IEC 16022 Parameters you need to evaluate, using the Symbol Quality tree control.
Once you have set these Data Matrix evaluation parameters, go to the Preferences Tab and set your Data Matrix Grading Report output preferences.
After your output preferences are set, click the Data Matrix Grading button.
There will be a wait of a few seconds, and then the evaluation results will appear in the Symbol Quality view, in a format similar to the one shown below.
If you want to view the results in a report format, click the Save Report button. The report will be output in the format you chose in the Preferences dialog.
8-12
MINI Hawk Xi High Performance Imager User Manual
Page 215
Symbol Quality
Microscan Symbol Quality Output Percent Cell Damage (Data Matrix Only) Definition: Serial Cmd: Default: Options:
When this feature is enabled, the cell damage percentage is appended to data output. <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle> Disabled 0 = Disabled 1 = Enabled
Total Read Time Definition: Serial Cmd: Default: Options:
The time that transpires between the image capture and the output of the decoded data, including locate time. When enabled, the total read time is appended to the symbol data. <K710,percent cell damage,total read timea,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle> Disabled 0 = Disabled 1 = Enabled a. Total Read Time applies globally to all three Symbol Quality standards.
Capture Time Definition: Serial Cmd: Default: Options:
Capture time (in milliseconds) is a fixed “overhead” that includes the time of capture and transfer of the image. When enabled, the capture time is appended to the symbol data. <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle> Disabled 0 = Disabled 1 = Enabled
Locate Time Definition: Serial Cmd: Default: Options:
The time in milliseconds from the start of image processing until the symbol has been located and is ready to be decoded. When enabled, the locate time is appended to the symbol data. <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle> Disabled 0 = Disabled 1 = Enabled
MINI Hawk Xi High Performance Imager User Manual
8-13
Page 216
Microscan Symbol Quality Output
Decode Time Definition: Serial Cmd: Default: Options:
The time in milliseconds required to decode a symbol. When enabled, the decode time is appended to the symbol data. <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle> Disabled 0 = Disabled 1 = Enabled
Pixels Per Element (Data Matrix Only) Definition:
Serial Cmd: Default: Options:
The number of pixels for each element, either dark or light for both x and y directions. When enabled, the pixels per element value is appended to the symbol data. <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle> Disabled 0 = Disabled 1 = Enabled
Error Correction Level (Data Matrix Only) Definition: Serial Cmd: Default: Options:
Outputs the Data Matrix ECC level. When enabled, the ECC level is appended to the symbol data. <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle> Disabled 0 = Disabled 1 = Enabled
Matrix Size (Data Matrix Only) Definition: Serial Cmd: Default: Options:
8-14
Defines the symbol matrix size, in number of pixels in both the x and y axis. When enabled, the matrix size value is appended to the symbol data. <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle> Disabled 0 = Disabled 1 = Enabled
MINI Hawk Xi High Performance Imager User Manual
Page 217
Symbol Quality
Quiet Zone (Data Matrix Only) Definition: Serial Cmd: Default: Options:
When this feature is enabled, the size of the quiet zone is evaluated and a PASS or FAIL message is appended to the symbol data. <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle> Disabled 0 = Disabled 1 = Enabled
Symbol Angle (Data Matrix Only) Definition: Serial Cmd: Default: Options:
When this feature is enabled, the symbol orientation is appended to data output as a degree value representing the angle of the Data Matrix symbol’s L-shaped finder pattern relative to the imager. <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle> Disabled 0 = Disabled 1 = Enabled
MINI Hawk Xi High Performance Imager User Manual
8-15
Page 218
Microscan Symbol Quality Output by ESP
Microscan Symbol Quality Output by ESP ESP’s Symbol Quality interface allows you to evaluate Data Matrix symbols for compliance with a rigorous set of standards, such as Locate Time, Capture Time, and Decode Time. First, determine which parameters you want to evaluate, using the Symbol Quality tree control.
Once you have set these Data Matrix evaluation parameters, go to the Preferences Tab and set your Data Matrix Grading Report output preferences.
After your output preferences are set, click the Data Matrix Grading button.
There will be a wait of a few seconds, and then the evaluation results will appear in the Symbol Quality view, in a format similar to the one shown below.
If you want to view the results in a report format, click the Save Report button. The report will be output in the format you chose in the Preferences dialog.
8-16
MINI Hawk Xi High Performance Imager User Manual
Page 219
9 Matchcode Contents Matchcode by ESP ....................................................................................................................... 9-2 Matchcode Serial Commands ...................................................................................................... 9-3 Overview of Matchcode ................................................................................................................ 9-4 Matchcode Type ........................................................................................................................... 9-5 Match Replace............................................................................................................................ 9-10 Mismatch Replace ...................................................................................................................... 9-11 New Master Pin .......................................................................................................................... 9-12
This section explains the MINI Hawk Xi’s matchcode output functions and the master symbol database setup.
MINI Hawk Xi High Performance Imager User Manual
9-1
Page 220
Matchcode by ESP
Matchcode by ESP
Click the Parameters button and then the Matchcode tab.
To open nested options, single-click the +.
9-2
To change a setting, double-click the setting and use your cursor to scroll through the options.
MINI Hawk Xi High Performance Imager User Manual