Page 11
Introduction
Statement of RoHS Compliance All Microscan readers with a ‘G’ suffix in the FIS number are RoHS-Compliant. All compliant readers were converted prior to March 1, 2007. All standard accessories in the Microscan Product Pricing Catalog are RoHS-Compliant except 20-500013-01 and 98-000039-02. These products meet all the requirements of “Directive 2002/95/EC” European Parliament and the Council of the European Union for RoHS compliance. In accordance with the latest requirements, our RoHS-Compliant products and packaging do not contain intentionally added Deca-BDE, Perfluorooctanes (PFOS) or Perfluorooctanic Acid (PFOA) compounds above the maximum trace levels. To view the document stating these requirements, please visit: http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=CELEX:32002L0095:EN:HTML and http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2006:372:0032:0034:EN:PDF
Please contact your sales manager for a complete list of Microscan’s RoHS-Compliant products. This declaration is based upon information obtained from sources which Microscan believes to be reliable, and from random sample testing; however, the information is provided without any representation of warranty, expressed or implied, regarding accuracy or correctness. Microscan does not specifically run any analysis on our raw materials or end product to measure for these substances. The information provided in this certification notice is correct to the best of Microscan’s knowledge at the date of publication. This notice is not to be considered a warranty or quality specification. Users are responsible for determining the applicability of any RoHS legislation or regulations based on their individual use of the product. In regards to “RoHS Directive 2011_65_EU” Microscan produces Monitoring and Control Instruments as well as Industrial Monitoring & Control Instruments as defined within the directive. Microscan has developed and is implementing a RoHS2 compliance plan with the intention of bringing all active products listed in our current marketing literature within full compliance as per the directive deadlines. Key milestones for the transition plan are as follows: • Complete internal product audit by July 2014. • Initial “Monitoring and Control Instruments” RoHS2 compliant products available by December 2014 • Initial “Industrial Monitoring & Control Instruments” RoHS2 compliant products available by July 2015 • All new products introduced in 2015 are expected to be WEEE & RoHS2 compliant. Microscan will mark the products with the ‘CE’ marking that complies with the RoHS2 process to acquire ‘CE’ certification per the example given: Example >> Machinery directive + EMC directive + RoHS2 = Declaration of Conformity.
MINI Hawk Xi High Performance Imager User Manual xi
Page 12
Statement of RoHS Compliance xii
MINI Hawk Xi High Performance Imager User Manual
Page 13
1 Quick Start Contents Step 1 Check Hardware................................................................................................................ 1-2 Step 2 Connect the System .......................................................................................................... 1-3 Step 3 Position Imager and Symbol.............................................................................................. 1-4 Step 4 Install ESP ......................................................................................................................... 1-5 Step 5 Select Model...................................................................................................................... 1-6 Step 6 Connect ............................................................................................................................. 1-7 Step 7 Locate the Symbol in the Field of View ............................................................................. 1-8 Step 8 Calibrate ......................................................................................................................... 1-10 Step 9 Test Read Rate .............................................................................................................. 1-11 Step 10 Configure the Imager in ESP........................................................................................ 1-12 Step 11 Save Configuration in ESP ........................................................................................... 1-13
This chapter is designed to get your MINI Hawk Xi up and running quickly, using the EZ button or ESP (Easy Setup Program). Following these steps will allow you to get a sense of the imager’s capabilities and to test sample symbols. Detailed setup information for installing the imager into your actual application can be found in the subsequent chapters.
MINI Hawk Xi High Performance Imager User Manual
1-1
Page 14
Check Hardware
Step 1, Check Hardware Item
1
2 3 4
Description
Part Number FIS-6310-CLSOG
MINI Hawk Xi (C)ommunication: 1 (Ethernet) (L)ens: 1 = Standard Density; 2 = High Density; 3 = Ultra High Density (S)ensor: 0 = WVGA; 1 = SXGA (O)ption: 0 = Standard; 1 = Custom QX-1 Interface Device 98-000103-02 Power Supply, M12 12-pin Socket, 1.3 m (Screw-On) 97-000003-03 Photo Sensor, M12 4-pin Plug, NPN, Dark On, 2 m 99-000020-02
1 1
2
3 3
Ethernet Standalone without QX-1
4
Ethernet Standalone with QX-1
Caution: Be sure that all cables are connected BEFORE applying power to the system. Always power down BEFORE disconnecting any cables.
1-2
MINI Hawk Xi High Performance Imager User Manual
Page 15
Quick Start
Step 2, Connect the System Ethernet Standalone without QX-1 • Connect the M12 (power and I/O) end of the imager’s cable to the power supply (3). • Connect the RJ45 (Ethernet) end of the imager’s cable to the host. • Plug in the power supply to apply power to the imager.
Ethernet Standalone with QX-1 • Connect the M12 (power and I/O) end of the imager’s cable to “2” on the QX-1 (2). • Connect the RJ45 (Ethernet) end of the imager’s cable to the host. • Connect the power supply (3) to “3” on the QX-1. • Connect the photo sensor (4) to “T” on the QX-1. • Plug in the power supply to apply power to the imager.
1 1
2
3 3
Ethernet Standalone without QX-1
4
Ethernet Standalone with QX-1
Caution: Be sure that all cables are connected BEFORE applying power to the system. Always power down BEFORE disconnecting any cables.
MINI Hawk Xi High Performance Imager User Manual
1-3
Page 16
Position Imager and Symbol
Step 3, Position Imager and Symbol • Position the imager at a focal distance between 2 and 6 inches from the symbol. • Tip the imager relative to the symbol to avoid the glare of direct (specular) reflection. The case parting line should be perpendicular to the plane of the symbol by either pitching the symbol or the imager as shown. • Position the imager in a place with as little ambient light as possible. • Symbols can be rotated (tilted) at any angle; however, for best results symbols should be aligned with the FOV (field of view).
Imager and Symbol Orientation • In the case of linear symbols, aligning the bars in the direction of their movement (“ladder” orientation) will minimize the chances of blurring, and will produce better reads. Important: Avoid excessive skew or pitch. Maximum skew is ±30°; maximum pitch is ±30°. The illustration below shows skew axis, pitch axis, and tilt axis. Skew axis Tilt axis
Pitch axis Scan line
Imager and Symbol Orientation Note: For accuracy of testing and performance, Microscan recommends using a mounting arm adapter kit. Contact your Microscan sales manager for details about mounting arm adapter kits and other accessories. 1-4
MINI Hawk Xi High Performance Imager User Manual
Page 17
Quick Start
Step 4, Install ESP ESP Software can be found on the Microscan Tools Drive that is packaged with the MINI Hawk Xi. 1. Follow the prompts to install ESP from the Tools Drive. 2. Click on the ESP icon to run the program.
Note: ESP can also be installed from the Download Center at www.microscan.com.
Minimum System Requirements • 233 MHz Pentium PC • Windows 8, 7, Vista, or XP operating system (32-bit or 64-bit) • Internet Explorer 6.0 or higher • 128 MB RAM or greater • 160 MB free disk space • 800 x 600 256 color display (1024 x 768 32-bit color recommended)
MINI Hawk Xi High Performance Imager User Manual
1-5
Page 18
Select Model
Step 5, Select Model When you start ESP, the following menu will appear:
1. Click the button showing the MINI Hawk Xi. 2. Click OK. Note: You can also double-click the MINI Hawk Xi button to make your selection. 3. Click Yes when this dialog appears:
Note: If you need to select another model later, click the Switch Model button near the top of the screen or use Model > New Model in the menu toolbar.
1-6
MINI Hawk Xi High Performance Imager User Manual
Page 19
Quick Start
Step 6, Connect • Click Connect on the menu toolbar, and then select Connection Wizard. • Select the communication interface required by your application. • Configure settings as required by the application, and click Connect.
• When a connection is established, the green indicator in the status bar at the bottom right of the screen will be visible:
Important: The imager is in Continuous Read Mode by default. For best connection results, be sure that no decodable symbols are within the imager’s field of view while attempting to connect. MINI Hawk Xi High Performance Imager User Manual
1-7
Page 20
Locate the Symbol in the Field of View
Step 7, Locate the Symbol in the Field of View Locate by ESP • In ESP’s EZ Mode, click the Locate button to enable the blue target pattern.
The symbol in the field of view will appear in the video view beneath the Locate and Calibrate buttons, and you will see the blue target pattern projected from the front of the imager. • Center the target pattern on the symbol. At 2 to 3 inches, the pattern resembles an X. At 3 to 6 inches, the pattern resembles a V.
Center on object in field of view.
Target pattern shown as it would appear between 3 and 6 inches.
Important: The entire symbol should fall within the field of view (FOV) of the imager. The field of view is what appears in ESP’s Locate/Calibrate window in EZ Mode. • Click the Stop button to end the Locate function.
1-8
MINI Hawk Xi High Performance Imager User Manual