Page 161
I/O Parameters
No Read Message Usage: Definition:
Used in applications where the host needs serial verification that a symbol has not been read and especially useful in new print verification. When enabled, and if no symbol has been decoded before timeout or the end of the read cycle, the No Read message will be transmitted to the host.
No Read Message Mode Serial Cmd: Default: Options:
<K714,No Read message status,No Read message> Enabled 0 = Disabled 1 = Enabled
Disabled Only symbol data is output after a read cycle.
Enabled When the imager is in a triggered mode, a No Read message will be appended for each failed read attempt.
No Read Message Definition: Serial Cmd: Default: Options:
Any combination of ASCII characters can be defined as the No Read message. <K714,No Read message status,No Read message> NOREAD A string of up to 64 characters.
Note: No Read Message will only be transmitted if Symbol Data Output is set to Match, Mismatch, or Good Read. No Read Message can be set to any ASCII character. Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K714h,,3C> For >: <K714h,,3E> For , : <K714h,,2C>
MINI Hawk Xi High Performance Imager User Manual
7-7
Page 162
Read Duration Output
Read Duration Output Usage: Definition:
Useful in evaluating actual read cycle timing results, especially when initially setting up an application to determine maximum line speed (obtainable based on spacing between symbols.) When enabled the duration of the read cycle (in milliseconds) is appended to the symbol data. The read duration is the time from the beginning of the read cycle until data is output.
Read Duration Output Mode Serial Cmd: Default: Options:
<K706,status,separator> Disabled 0 = Disabled 1 = Enabled
Important: To measure the entire read cycle when in External Level trigger mode, set When to Output Symbol Data to End of Read Cycle. This output can measure over 49 days’ worth of duration; if exceeded, the “OVERFLOW” message will be output in place of the duration.
Read Duration Output Separator Definition: Serial Cmd: Default: Options:
User defined character that separates the symbol information from the Read Duration Output. <K706,status,separator> [space character] Any ASCII character.
Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K706h,,3C> For >: <K706h,,3E> For , : <K706h,,2C>
7-8
MINI Hawk Xi High Performance Imager User Manual
Page 163
I/O Parameters
Output Indicators The MINI Hawk Xi has a beeper and three LED arrays, as follows: 1. A target pattern of blue LEDs for centering the field of view, which is projected from the front of the imager . 2. An array of green LEDs projected from the front of the imager that can be programmed to flash in response to user-defined conditions. 3. A row of five status LEDs on the side of the imager.
Green Flash Mode Usage: Definition: Serial Cmd: Default: Options:
Used as a visual verification that a good read has occurred. An array of green LEDs in the front of the imager can be programmed to flash in response to user-defined conditions. <K750,green flash mode,target pattern status,green flash duration> Good Read 0 = Disabled 1 = Good Read 2 = Static Presentation 3 = Match 4 = Mismatch 5 = Strobe
Disabled Green flash LEDs are disabled.
Good Read Green flash LEDs will flash when a good read condition is met or when Matchcode is enabled and a match occurs.
MINI Hawk Xi High Performance Imager User Manual
7-9
Page 164
Output Indicators
Static Presentation Mode Static Presentation Mode is used in conjunction with Continuous Read Mode: <K200,0>. When operating in Static Presentation Mode, the red LEDs will illuminate while the imager is searching for a symbol in Continuous Read Mode. When a symbol is placed in the field of view and a good read occurs, the green LEDs will illuminate and stay on for the duration of time set in Green Flash Duration. Only one read will occur during that time unless more than one symbol is enabled in Number of Symbols. Note: If Static Presentation Mode is selected but the imager is not in Continuous Read, the Green Flash will not occur. To use Static Presentation: 1. Enable Continuous Read. 2. Select the number of symbols. 3. Enable Static Presentation in Green Flash Mode. 4. Select the read time in Green Flash Duration.
Match The green LEDs will flash when a match condition is met. If multisymbol is enabled, then green flash LEDs will illuminate only if all symbols qualify as a match. If matchcode is disabled, then this mode will activate the LEDs on a good read.
Mismatch Same as Match, except that LEDs will illuminate on a mismatch.
Strobe Green flash LEDs will act as an illumination strobe for image capture. If it is required that the green flash LEDs be the only illumination for image capture, then the internal illumination LEDs can be disabled.
7-10
MINI Hawk Xi High Performance Imager User Manual
Page 165
I/O Parameters
Target Pattern Usage: Definition: Serial Cmd: Default: Options:
Assists users in positioning and locating symbols in the center of the imager’s field of view. The user can control when the targeting system is ON or OFF, and can save this condition for power-on. <K750,green flash mode,target pattern status,green flash duration> Always ON 0 = Always OFF 1 = ON only when not in the read cycle 2 = ON only when in the read cycle 3 = Always ON
Always OFF The target pattern will remain OFF at all times unless overridden by the EZ button or operational command.
ON Only When Not in the Read Cycle The target pattern is always ON except during the read cycle. If the EZ button or operational command overrides this setting, the target pattern will remain on at all times.
ON Only When in the Read Cycle The target pattern will remain OFF except during the read cycle. If the EZ button or operational command overrides this setting, the target pattern will remain on at all times.
Always ON The target pattern is always ON.
MINI Hawk Xi High Performance Imager User Manual
7-11
Page 166
Output Indicators
Green Flash Duration Usage: Definition: Serial Cmd: Default: Options:
7-12
Provides visual verification that a good read has occurred. When a good read occurs, the green LEDs will illuminate and stay on for the time set in the Green Flash Duration value. <K750,green flash mode,target pattern status,green flash duration> 100 (1 second) 0 to 65535 (in 10 ms increments)
MINI Hawk Xi High Performance Imager User Manual
Page 167
I/O Parameters
Beeper Usage: Definition: Serial Cmd: Default: Options:
An audible verification that either a good read or a No Read has occurred. A beep is emitted after each good read or No Read. <K702,beeper status> Good Read 0 = Disabled 1 = Good Read 2 = No Read
Note: The beeper will also sound at any of the following times: • When the imager is defaulted. • When a send/save command is sent from ESP. • At the conclusion of a calibration procedure. • When a <Z>, <Zp>, <Zrd>, or <K701,,1> command is sent.
MINI Hawk Xi High Performance Imager User Manual
7-13
Page 168
LED Configuration
LED Configuration Usage: Definition: Serial Cmd: Default: Options:
Useful as a visible indicator of read rates and symbol quality. Determines the mode in which the status LEDs operate. <K737,LED mode,ISO/IEC 16022 grade> Standard 0 = Standard 1 = ISO/IEC 16022 grade
In ISO/IEC 16022 grade mode the LEDs represent the grade of the first Data Matrix symbol decoded in the read cycle. The parameter to be graded is set in the ISO/IEC 16022 Grade options. For example, to program the LEDs to indicate the ISO/IEC 16022 print growth grade, set LED Mode to ISO/IEC 16022 Grade and set ISO/IEC 16022 Grade to Print Growth. If all the LEDs from 20% to 100% are illuminated, the read result is a grade A; if only the 20% LED is illuminated, the result is a grade F.
Standard In Standard Mode, the STATUS LED indicates read cycle status and the GOOD READ LED illuminates upon a good read at the end of a read cycle. In a read rate test, these LEDs represent the percentage of good reads per images captured.
ISO/IEC 16022 Grade Usage: Definition: Serial Cmd: Default: Options:
7-14
Provides visual grading of specific ISO/IEC 16022 parameters. Determines which ISO/IEC 16022 parameter the imager will grade via the LEDs. <K737,LED mode,ISO/IEC 16022 grade> Final Grade 0 = Final Grade 1 = Symbol Contrast 2 = Print Growth 3 = Axial Non-Uniformity 4 = Unused ECC
MINI Hawk Xi High Performance Imager User Manual
Page 169
I/O Parameters
Serial Verification Allows the user to verify configuration command status.
Serial Command Echo Status Usage:
Definition:
Function:
Serial Cmd: Default: Options:
This command is useful in removing any doubt about the imager’s interpretation of any configuration command. For example, if the current preamble is “SOM” and <K701,1,START> is entered, the imager will echo back <K701,SOM> since the attempted entry “START” exceeds the four character limit for that command. Therefore, it is rejected and the existing “SOM” message is echoed back and remains the preamble message. When enabled, a configuration command received from the host is echoed back to the Host Imager host with the resultant settings. If a command with multiple fields is processed, some of the fields may have been processed properly while others were not. The changes will appear in the string echoed back so that the user will know which fields did or did not change. <K701,serial command echo status,serial command beep status, control/hex output> Disabled 0 = Disabled 1 = Enabled
Serial Command Beep Status Usage: Definition: Function:
Serial Cmd: Default: Options:
Used to audibly verify the acceptance and validity of a command. Causes the imager to beep once whenever a K command is entered to indicate that the command was accepted and processed. If an invalid command is entered, the imager beeps 5 times to indicate an invalid entry. However, this does not necessarily mean that all data fields have been entered incorrectly. Only one bad field needs to be found in order to activate the 5 beep response. <K701,serial command echo status,serial command beep status, control/hex output> Disabled 0 = Disabled 1 = Enabled
MINI Hawk Xi High Performance Imager User Manual
7-15
Page 170
Serial Verification
Control/Hex Output Usage: Definition:
Serial Cmd: Default: Options:
7-16
Useful for viewing settings with binary characters when using serial commands on a terminal. Determines the response to a Serial Command Echo or status request command. When set to Control, two characters are transmitted to represent a non-displayable character. For example, a carriage return will be shown as: ^M. <K701,serial command echo status,serial command beep status,control/hex output> Control 0 = Control 1 = Hex
MINI Hawk Xi High Performance Imager User Manual