Page 121
Symbologies
Code 39 Usage: Definition: Serial Cmd: Default: Options:
Code 39 is considered the standard for non-retail 1D symbology. An alphanumeric symbology with unique start/stop code patterns, composed of 9 black and white elements per character, of which 3 are wide. <K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> Enabled 0 = Disabled 1 = Enabled
Check Character Status (Code 39) Serial Cmd: Default: Options:
<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> Disabled 0 = Disabled 1 = Enabled
Check Character Output Status (Code 39) Usage: Definition:
Serial Cmd: Default: Options:
Check Character Output Status, added to the symbol, provides additional data security. When enabled, the check character character is read and compared along with the symbol data. When disabled, symbol data is sent without the check character. Note: With Check Character Output Status and an External or Serial trigger option enabled, an invalid check character calculation will cause a No Read message to be transmitted at the end of the read cycle. <K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> Disabled 0 = Disabled 1 = Enabled
MINI Hawk Xi High Performance Imager User Manual
6-9
Page 122
Code 39
Large Intercharacter Gap (Code 39) Usage:
Definition: Serial Cmd: Default: Options:
Large Intercharacter Gap is helpful for reading symbols that are printed out of specification. Important: Do not use Large Intercharacter Gap with Narrow Margins enabled, because a large intercharacter gap (over 3x) could cause a narrow margin (5x) to be interpreted as an intercharacter gap. When enabled, the imager can read symbols with gaps between symbol characters that exceed three times (3x) the narrow element width. <K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (Code 39) Definition: Serial Cmd: Default: Options:
When enabled, the imager will check the symbol length against the symbol length field. If disabled, any length will be considered valid. <K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (Code 39) Usage: Definition: Serial Cmd: Default: Options:
6-10
Fixed Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted. Specifies the exact number of characters that the imager will recognize (this does not include start and stop and check character characters). The imager ignores any symbology that does not match the specified length. <K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 10 1 to 64
MINI Hawk Xi High Performance Imager User Manual
Page 123
Symbologies
Full ASCII Set (Code 39) Usage:
Definition:
Serial Cmd: Default: Options:
Must be enabled when reading characters outside the standard character set (0-9, A-Z, etc.) The user must know in advance whether or not to use the Full ASCII Set option. Since Full ASCII Set requires two code words to encode one character, it is less efficient. Standard Code 39 encodes 43 characters; zero through nine, capital “A” through capital “Z”, minus symbol, plus symbol, forward slash, space, decimal point, dollar sign, and percent symbol. When Full ASCII Set is enabled, the imager can read the full ASCII character set, from 0 to 255. <K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> Disabled 0 = Disabled 1 = Enabled
MINI Hawk Xi High Performance Imager User Manual
6-11
Page 124
Code 128/EAN 128
Code 128/EAN 128 Usage: Definition: Serial Cmd: Default: Options:
Code 128 is a smaller symbology useful in applications with tight spots and high security needs. A very dense alphanumeric symbology. It encodes all 128 ASCII characters, it is continuous, has variable length, and uses multiple element widths measured edge to edge. <K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding> Enabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (Code 128/EAN 128) Definition: Serial Cmd: Default: Options:
When enabled, the imager will check the symbol length against the symbol length field. If disabled, any length will be considered a valid symbol. <K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding> Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (Code 128/EAN 128) Usage: Definition:
Serial Cmd: Default: Options:
6-12
Fixed Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted. This specifies the exact number of characters that the imager will recognize (this does not include start, stop, and check character characters). The imager ignores any symbol not having the specified length. <K474,status,fixed symbol length status,fixed symbol length,EAN 128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> 10 1 to 64
MINI Hawk Xi High Performance Imager User Manual
Page 125
Symbologies
EAN 128 Status (Code 128/EAN 128) Definition:
Serial Cmd: Default: Options:
When this field is disabled, the imager will not check any Code 128 labels for conformance to EAN requirements, or perform any special formatting. When enabled, the imager can read symbols with or without a function 1 character in the first position. If a symbol has a function 1 character in the first position, it must conform to EAN format. Symbols that conform to EAN format will also be subject to the special output formatting options available in this command. Note: Code 128 status must be enabled for EAN status to be active. If EAN status is required, the imager will only decode symbols that have a function 1 character in the first position and that conform to EAN format. All symbols read will be subject to the special output formatting options available in this command. Note: Code 128 status must be enabled for EAN status to be active. <K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding> Disabled 0 = Disabled 1 = Enabled 2 = Required
Output Format (Code 128/EAN 128) Definition:
Serial Cmd:
Default: Options:
In Standard, the imager will not apply special EAN output formatting options. In Application, the imager will apply the special EAN output formatting options to decoded EAN-conforming symbols. <K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding> Standard 0 = Standard 1 = Application
Application Record Separator Status (Code 128/EAN 128) Definition: Serial Cmd: Default: Options:
When enabled, an EAN separator will be inserted into the output between fields whenever an EAN-conforming symbol is decoded and EAN output formatting applies. <K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding> Disabled 0 = Disabled 1 = Enabled
MINI Hawk Xi High Performance Imager User Manual
6-13
Page 126
Code 128/EAN 128
Application Record Separator Character (Code 128/EAN 128) Definition: Serial Cmd:
This is an ASCII character that serves as an EAN separator in formatted EAN output. <K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding>
Default:
,
Options:
Any ASCII character (7 bit)
Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K474h,,,,,,,3C> For >: <K474h,,,,,,,3E> For , : <K474h,,,,,,,2C>
Application Record Brackets (Code 128/EAN 128) Definition: Serial Cmd: Default: Options:
If an EAN-conforming symbol is decoded and EAN formatting applies, this feature places bracket characters around the application identifiers in the formatted output. <K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding> Disabled 0 = Disabled 1 = Enabled
Application Record Padding (Code 128/EAN 128) Definition: Serial Cmd: Default: Options:
6-14
This feature causes the imager to pad variable-length application fields with leading zeroes. This is not done for the last field of a symbol. <K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding> Enabled 0 = Disabled 1 = Enabled
MINI Hawk Xi High Performance Imager User Manual
Page 127
Symbologies
BC412 Usage: Definition:
Serial Cmd: Default: Options:
Widely used in semiconductor manufacturing. Particularly useful where speed, accuracy, and ease of printing are required. BC412 (Binary Code 412), a proprietary IBM symbology since 1988, is an alphanumeric symbol with a set of 35 characters, each encoded by a set of 4 bars in 12 module positions. All bars have a single width; it is the presence (1) or absence (0) of bars in each of the twelve module positions that make BC412 binary. This symbology is also bi-directional and self-clocking, with a start character and a stop character. <K481,status,check character output,fixed symbol length status,fixed symbol length> Disabled 0 = Disabled 1 = Enabled
Check Character Output (BC412) Usage: Definition: Serial Cmd: Default: Options:
Check Character Output, added to the symbol, provides additional security. When enabled, the check character character is read and compared along with the symbol data. When disabled, symbol data is sent without the check character. <K481,status,check character output,fixed symbol length status,fixed symbol length> Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (BC412) Definition: Serial Cmd: Default: Options:
When enabled, the imager will check the symbol length against the symbol length field. If disabled, any length will be considered valid. <K481,status,check character output,fixed symbol length status,fixed symbol length> Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (BC412) Definition: Serial Cmd: Default: Options:
When enabled, the check character character is read and compared along with the symbol data. When disabled, symbol data is sent without the check character. <K481,status,check character output,fixed symbol length status,fixed symbol length> 10 1 to 64
MINI Hawk Xi High Performance Imager User Manual
6-15
Page 128
Interleaved 2 of 5
Interleaved 2 of 5 Usage:
Definition:
Serial Cmd: Default: Options:
I-2/5 has been popular because it is the most dense symbology for printing numeric characters less than 10 characters in length; however, Microscan does not recommend this symbology for any new applications because of inherent problems such as truncation. A dense, contimuous, self-checking, numeric symbology. Characters are paired together so that each character has five elements, two wide and three narrow, representing numbers 0 through 9, with the bars representing the first character and the interleaved spaces representing the second character. (A check character is highly recommended). Important: You must set Symbol Length in order to decode I-2/5 symbols, unless Range Mode is enabled. <K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> Enabled 0 = Disabled 1 = Enabled
Check Character Status (Interleaved 2 of 5) Usage: Definition: Serial Cmd: Default: Options:
This option is not typically used, but it can be enabled for additional security in applications where the host requires redundant check character verification. An error correcting routine in which the check character character is added. <K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> Disabled 0 = Disabled 1 = Enabled
Check Character Output Status (Interleaved 2 of 5) Definition: Serial Cmd: Default: Options:
6-16
When enabled, a check character character is sent along with the symbol data for added data security. <K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> Disabled 0 = Disabled 1 = Enabled
MINI Hawk Xi High Performance Imager User Manual
Page 129
Symbologies
Symbol Length #1 (Interleaved 2 of 5) Usage: Definition: Serial Cmd: Default: Options:
Useful in applications where I 2/5 symbols of a specific length are required. The Symbol Length # 1 field is one of two fields against which the decoded symbol is compared before accepting it as valid or rejecting it. <K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 16 0 to 64, even only Important: If Range Mode is disabled, the length of the symbol must match either Symbol Length # 1 or Symbol Length # 2 to be considered a valid symbol. If Range Mode is enabled, Symbol Length # 1 and Symbol Length # 2 form a range into which the length of the symbol must fall to be considered valid.
Symbol Length #2 (Interleaved 2 of 5) Usage: Definition: Serial Cmd: Default: Options:
Useful in applications where I 2/5 symbols of a specific length are required. The Symbol Length # 2 field is one of two fields against which the decoded symbol is compared before accepting it as valid or rejecting it. <K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 6 0 to 64, even only Important: If Range Mode is disabled, the length of the symbol must match either Symbol Length # 2 or Symbol Length # 1 to be considered a valid symbol. If Range Mode is enabled, Symbol Length # 2 and Symbol Length # 1 form a range into which the length of the symbol must fall to be considered valid.
MINI Hawk Xi High Performance Imager User Manual
6-17
Page 130
Interleaved 2 of 5
Guard Bar Status (Interleaved 2 of 5) Note: Whenever Guard Bar is enabled, the presence of guard bars (also called “bearer bars”) is required for decoding to take place. Usage: Definition: Serial Cmd: Default: Options:
Useful when I-2/5 multisymbols are enabled to prevent false data output. This typically occurs with highly tilted or skewed symbols. A guard bar is a heavy bar, at least twice the width of the wide bar, surrounding the printed I-2/5 symbol and helping to prevent false reads. <K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> Disabled 0 = Disabled 1 = Enabled
Range Mode Status (Interleaved 2 of 5) Usage: Definition:
Serial Cmd: Default: Options:
6-18
Useful in applications where I 2/5 symbols of a specific length are required. When Range Mode is disabled, the imager checks the value of the symbol length against the values set in Symbol Length # 1 and Symbol Length # 2. If the symbol length does not match either of the preset values, then it is rejected as invalid. When Range Mode is enabled, Symbol Length # 1 and Symbol Length # 2 are combined to form a range of valid symbol lengths. Any symbol length that does not fall into this range is rejected as an invalid symbol. Either of the preset symbol length values in the Symbol Length # 1 and Symbol Length # 2 fields can form the start or end of the range. <K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> Enabled 0 = Disabled 1 = Enabled
MINI Hawk Xi High Performance Imager User Manual