Page 331
Utilities
Device Control Device Control by ESP
Device Control by Serial Command Output 1 Pulse Sending <L1> activates the link between Output 1 (+) and Output 1 (–) of the host connector (regardless of Master Symbol or Output 1 status).
Output 2 Pulse Sending <L2> activates the link between Output 2 (+) and Output 2 (–) of the host connector (regardless of Master Symbol or Output 2 status).
Output 3 Pulse Sending <L3> activates the link between Output 3 (+) and Output 3 (–) of the host connector (regardless of Master Symbol or Output 3 status).
Disable Reader Sending <I> will turn the imager OFF, end the current read cycle, and will not allow the imager to enter another read cycle until turned ON. This feature is useful during extended periods of time when no symbols are being decoded, or the imager is being configured. Disabling the imager will not affect any commands that have already been downloaded.
Enable Reader Sending <H> will turn the imager ON and allow it to enter read cycles.
Enable PDF Information Sending <a1> will cause PDF417 data to be prefaced with information consisting of ECC level (ECC level n), number of rows (n rows), number of columns (n columns), number of informative code words (n info code words), and the number of data characters (n data bits). Send <a1> again to disable PDF Information. Quadrus MINI Imager User’s Manual
13-7
Page 332
Differences from Default
Differences from Default Clicking the Differences from Default button will cause ESP to check all stored configuration settings and compare them to default settings. All settings that are different than default will appear in the left column (shown below), and descriptions of those settings will appear in the right column. Click this button for a list of ESP configuration settings that are different than default settings.
Click Generate Barcode to bring up the Bar Code Dialog. Then create configuration symbols containing the configuration commands of your choice.
Send configuration settings to the imager without saving by clicking Send to Reader.
Click Save As to save the report as plain text or a tab-delimited text file.
Send configuration settings to the imager and save in ESP by clicking Send and Save.
• To create a symbol containing any of the command settings in the table, click Generate Barcode. This will bring up the Bar Code Dialog. • To save the Differences from Default report, either as plain text or as a tab-delimited text file, click Save As. • Click Send and Save to send the settings to the imager and save them, or Send to Reader to send the settings without saving them. Important: The use the Differences from Default feature, you must connect to the imager and Receive Reader Settings via the Send/Recv button on the toolbar.
13-8
Quadrus MINI Imager User’s Manual
Page 333
Utilities
Master Database Important: The Master Database is used for all Matchcode modes except Sequential and Wild Card, both of which use Master Database Index # 1.
Master Database Overview Usage: Definition:
Used where more than one master symbol is required, as in a Multisymbol setup, for matching and other Matchcode operations. Allows the user to define up to 10 master symbols as the master symbol database, which can be entered by keyboard, scanned in, displayed, or deleted by serial or ESP commands.
1. Click the Master Database tab. 2. Enable Matchcode Type. 3. Set the Master Symbol Database Size. 4. Select the database index in which you want to enter the master symbol. 5. Do one of the following to enter master symbol data: a. Double-click the index row to type data directly into the index. b. Click the Read Symbol into Selected Index to enter the next decoded symbol. Set Master Symbol Database Size here.
Loads the next symbol decoded into the selected index.
Double-click a row to enter data into popup dialog box. Loads the imager’s saved master symbols into ESP.
Quadrus MINI Imager User’s Manual
Saves the displayed database to the imager.
13-9
Page 334
Master Database
Master Symbol Database Size Definition: Serial Cmd: Default: Options:
Number of Master Symbols allows you to select 1 to 10 master symbols for the master symbol database. <K231,master symbol database size> Note: You must follow this command with a save command <A> or <Z>. 1 1 to 10
Set Master Symbol Database Size here.
Caution: Since the total number of characters available for the master symbol database is 3000, changes to the Master Symbol Database Size will re-allocate the number of characters available for each master symbol and could cause existing master symbols to be deleted (except master symbol #1, unless it also exceeds the size limitation). The table below specifies the maximum number of characters available to each symbol according the number of master symbols defined, from 1 to 10. Master Symbol Number #1 #2 #3 #4 #5
13-10
Maximum Characters 3000 1500 1000 750 600
Master Symbol Number #6 #7 #8 #9 # 10
Maximum Characters 500 428 375 333 300
Quadrus MINI Imager User’s Manual
Page 335
Utilities
Enter Master Symbol Data Usage:
Allows you to enter master symbol data for any enabled master symbol index number (1 to 10), provided the total number of characters does not exceed the maximum allowed. Serial Cmd: <K231,master symbol number,master symbol data> Options: Enter data for 1 to 10 symbols (any combination of ASCII text up to the maximum allowed. For example, to enter data for master symbol 9, after making certain that master symbol database size is enabled for 9 or more symbols, send <K231,9,data>. Important: The ASCII characters <, >, and , can only be entered as hex pairs. See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values. ESP:
Caution: If no data is entered, the existing data will be deleted. 1. Open the Utilities menu. 2. Set the number of master symbols you want to create in Master Symbol Database Size. 3. Double-click on each symbol number you want to set up and copy, or type your data in the popup dialog and click OK.
4. When all your data has been entered, click the Send Database to the Reader button. Quadrus MINI Imager User’s Manual
13-11
Page 336
Request Master Symbol Data Definition:
Serial Cmd:
Returns master symbol data for any enabled master symbols from 1 to 10. For example, to request master symbol # 5, enter <K231?,5>. The imager transmits master symbol # 5 data in brackets in the following format: <5/>. If no master symbol data is available, the output will be: <5/>. <K231?,master symbol number> Caution: Be sure to add the ? or you will delete the master symbol. Note: This command returns the number of master symbols if no number is included.
ESP:
1. Click the Utilities button and the Master Database tab. 2. Click the Receive Reader’s Database button.
Request All Master Symbol Data Definition: Serial Cmd:
13-12
This command will return master symbol data for all symbols enabled (up to 10). <K231?>
Quadrus MINI Imager User’s Manual
Page 337
Utilities
Read Next Symbol as Master Symbol Definition: Serial Cmd:
ESP:
After you’ve set the size in the database, you can order the imager to read the next symbol as the master symbol for any given master symbol number. <Gmaster symbol number> To store the next symbol decoded as master symbol # 1, send: <G> or <G1>. To store the next symbol decoded as the master symbol for any other master symbol database number, send: <Gmaster symbol number [1-10]>. For example, <G5> will cause the next symbol read to be entered as master symbol # 5. In the Master Database tab under the Output Format menu, 1. Select the master symbol index number in which you want to store the symbol data. 2. Click the Read Symbol into Selected Index button. Caution: If you’ve selected an index which already has existing data, that data will be copied over by new decoded data when you use this command.
Request New Master Status Usage: Definition: Serial Cmd:
Informs the user when a new master symbol is pending and which position it is in. Returns the position in the master symbol database that will be loaded on the next read. <NEWM> The imager returns: <NEWM/next master to load> Once a symbol has been read and loaded, the status will be cleared and the response will be <NEWM/0>.
(See also New Master Pin in Chapter 9, Matchcode.)
Quadrus MINI Imager User’s Manual
13-13
Page 338
Delete Master Symbol Data Definition: ESP:
Serial Cmd:
13-14
You can directly delete the master symbol data by serial command or by ESP. 1. Click the Utilities button to access the master symbol. 2. Click the Master Database tab and double-click the symbol number you want to delete. 3. Delete text and click OK. <K231,master symbol number,> To delete a master symbol, enter the database number and a comma, but leave the data field empty. For example, to delete master symbol # 5, send the following: <K231,5,>. The command is entered with a blank master symbol data field, which tells the imager to delete the selected master symbol from the database.
Quadrus MINI Imager User’s Manual
Page 339
Utilities
Firmware Firmware by ESP
Firmware Update Application code versions are specific to your imager. Consult with your sales representative before downloading application code. If needed, an application code will be sent to you in the form of a *.mot file. To download application code: 1. First, be sure that your imager is connected to the host. 2. Apply power to the imager. 3. Before updating, you should verify the current firmware. 4. Click in the Firmware Update text box and select the file type you want to download. This will open a file locator box. 5. Navigate to the appropriate file (it will be a *.mot file), open the file and click Start. Caution: Do not interrupt power or disconnect the host cable while download is in progress. Be sure that each download is complete before moving on to the next. Important: When updating firmware, be sure that the application code and boot code versions are mutually compatible.
Quadrus MINI Imager User’s Manual
13-15
Page 340
Firmware
Firmware Verification Request Part Number by ESP You can send a request to the imager for part numbers, checksums, boot code, and application code. 1. Click the Firmware tab. 2. From the pulldown selection box to the left of the Request Part No. button, make your selection. 3. Select the code type to see its part number displayed in the text field to the right of the Request Part No. button.
Request Part Number by Serial Command • When you send <#> (a request for all product part numbers), the imager returns: <#b/BOOT_P/N><#a/APP_P/N><#p/PROFILE_P/N>. • When you send <#a> (a request for the application code part number), the imager returns: <#a/APP_P/N>. • When you send <#b> (a request for the boot code part number), the imager returns: <#b/BOOT_P/N>. • When you send <#p> (a request for profile module part numbers), the imager returns: <#p/PROFILE_P/N>.
13-16
Quadrus MINI Imager User’s Manual