Page 271
Camera and IP Setup
Evaluation In Evaluation, you can view images currently in the imager, capture and decode a symbol, save it as a digital file, and perform histogram and line scan evaluations. When you click on the Evaluation tab, you will see the images that are currently stored in the imager. Click Receive to refresh this view. Click Capture/Decode to display the current stored image. Only one capture and decode event will occur, regardless of read cycle settings. Click Read to trigger a read cycle. If there is enough time in the read cycle, up to 32 good reads (or 6 full-scale images) can be captured and displayed, depending on the size of the images, and depending on the number enabled in Number of Captures under Capture Mode in the Camera Setup menu tree to the left of the tabs. If you click Save, the current image will be saved to the location of your choice. Note: An image can only be saved in the format in which it was uploaded to ESP. JPEG images will be saved as .jpg, and bitmaps will be saved as .bmp. When you click the JPEG Image box, notice that the Line Scan button is grayed out. The JPEG option allows faster captures and transfers, but since the JPEG standard compresses image data, it is not suitable for the more rigorous demands of line scan evaluation. JPEG also allows you to adjust the image quality (resolution) by adjusting the sliding tab between 1 and 100, 1 being the lowest quality and 100 being the highest. When possible, use the highest quality; when image transfer speed must be increased, use a lower image quality setting. Adjustments for this setting will depend on your specific hardware and software limitations.
Quadrus MINI Imager User’s Manual
10-5
Page 272
Evaluation
Histogram Usage: Definition:
Useful in determining quality and contrast of symbols. A histogram is a graphic representation of the numeric count of the occurrence of each intensity (gray level) in an image. The horizontal axis represents the values of gray levels, and the vertical axis represents the number of pixels for each gray level.
Note: Since histograms are performed in the imager, the results will be saved regardless of whether the image was uploaded as a JPEG (.jpg) or a bitmap (.bmp). 1. From the Evaluation window, click the Histogram button. The current image is transferred into the histogram operation. This may take a moment, since all the relevant pixels are being evaluated intensively. 2. When the Histogram window opens, you may need to expand the window and/or adjust the scroll bars in order to bring the image into view. 3. To generate a histogram, click and drag your cursor diagonally across the symbol or a portion of the symbol. The image will be surrounded by an “area of interest box”, a dashed blue line with red anchor points that can be selected and moved by placing a cursor inside the box, and can be resized by clicking and dragging the anchor points.
10-6
Quadrus MINI Imager User’s Manual
Page 273
Camera and IP Setup
Threshold (Histogram) Enable Autothreshold is checked by default. To adjust the threshold manually, 1. Uncheck the Enable Autothreshold box. 2. Move the threshold marker (vertical green dashed line) in the Histogram chart. Hint: This should be midway between the maximum and minimum curves. 3. Click on the Send Threshold button to adopt the new threshold position.
Quadrus MINI Imager User’s Manual
10-7
Page 274
Evaluation
Line Scan 1. From the Evaluation tab, click the Line Scan button. A window like that shown below will appear. 2. Drag your cursor horizontally across the image. This will create a dashed horizontal line. Pixel information and a visual representation of the dark and light pixels will be displayed below the image.
When you center your cursor over the dashed line, it becomes a double arrow cross. This allows you to move the line anywhere in the window. You can also use your keyboard arrows to move the line incrementally in any direction. As with the histogram, the line scan compares light and dark pixels, but in a spatial distribution. On the Y axis of the graph below, 0 is black and 255 is white; the X axis represents the horizontal axis of the symbol as described by the line scan. When you click anywhere on the graph, a vertical red line appears at that point and its position and value (in terms of black-to-white) are updated in the Pixel Info table to the left of the graph (237 in this example). In addition, a horizontal dashed red line is displayed that indicates the average value.
10-8
Quadrus MINI Imager User’s Manual
Page 275
Camera and IP Setup
Calibration The Calibration interface in ESP is a powerful and intuitive way to optimize the imager’s performance. It allows the user to control several complex, simultaneous calibration operations, and to follow the progress of those operations using cues such as progress bars, real-time representations of calibration values, and other dynamic user feedback. See Chapter 4, Calibration, for full documentation of this feature.
ESP’s Calibration interface shown during a calibration routine
Quadrus MINI Imager User’s Manual
ESP’s Calibration interface shown after a calibration routine
10-9
Page 276
Window of Interest
Window of Interest The active pixel area of the image sensor is called the Window of Interest (WOI). The WOI allows the user to select an area of the field of view in which the desired symbol is located. The programmable window of interest increases decode speed, improves threshold, and makes it easy to select specific symbols from among several in the field of view. The user provides the upper-left pixel location and the size of the window to define the Window of Interest.
Caution: Window of Interest will shrink the field of view and therefore could cause symbols to be missed in dynamic applications.
10-10
Quadrus MINI Imager User’s Manual
Page 277
Camera and IP Setup
Window of Interest by ESP 1. From the Camera menu, click the WOI tab to bring up Window of Interest. If you haven’t already captured an image, click the Capture and Decode button to decode the present image. If successful, the Good Read indicator on the WOI tab will be green and the symbol will appear in the pane below. Note: You can resize the image by clicking and dragging the ESP window from the lower right corner. This is useful where very small symbols are being read. 2. Click and drag your cursor over the symbol that you want to isolate for reading. Notice that the surrounding area goes black. You can use the handles on the image area that you have just drawn to resize the region of interest. You can also click on the center of the window of interest and move it. 3. Test the new settings in Read Rate Mode.
Note: To remove the window of interest, click the Reset button or click anywhere in the WOI pane. Note that all pixels not in the WOI are defined as black. Because the imager has far less processing to do in a smaller window, read rates typically increase dramatically. One possible downside is that the chance of missing a symbol increases with the smaller window. Always verify that your WOI will be large enough to allow for any random movement of symbols in your field of view. Quadrus MINI Imager User’s Manual
10-11
Page 278
Window of Interest
Window of Interest by Serial Command The figure below shows where to locate the start position of the row and column pointers and how to measure the column depth and row width dimensions.
Top (Row Pointer) Definition: Defines the row position of the upper-left starting point of the window. Serial <K516,row pointer,column Cmd: pointer,row depth,column width> Default: 0 Options: 0 to (1024 - row depth)
WOI Row Pointer
WOI Column Pointer WOI Row Depth
WOI Column Width
Left (Column Pointer) Definition: Serial Cmd: Default: Options:
Defines the column position of the upper-left starting point of the window. <K516,row pointer,column pointer,row depth,column width> 0 0 to (1280 - column width)
Important: The column pointer setting must be an even value. If a user enters an odd value, it will be decreased automatically to the nearest even value. For example, if a user enters a setting of 101, it will automatically be reduced to 100 (although a user request for this setting would still show 101).
Height (Row Depth) Definition: Serial Cmd: Default: Options:
Defines the size, in rows, of the window. Maximum value is defined as the maximum row size of the image sensor minus the Top value. <K516,row pointer,column pointer,row depth,column width> 1024 3 to (1024 - row pointer)
Width (Column Width) Definition: Serial Cmd: Default: Options:
Defines the column position of the upper-left starting point of the window. <K516,row pointer,column pointer,row depth,column width> 1280 8 to (1280 - column pointer)
Important: The column width value must be a modulus 8 value. If a user enters a nonmodulus 8 value, it will be decreased automatically to the nearest modulus 8 value. For example, if a user enters a setting of 639, it will automatically be reduced to 632 (although a user request for this setting would still show 639). 10-12
Quadrus MINI Imager User’s Manual
Page 279
Camera and IP Setup
Configuration Database The Configuration Database allows the user to manage multiple configuration profiles. It is a useful tool in applications that require several different imager configurations to be applied sequentially, and it allows the user to perform far more complex operations than would be possible with only one set of configuration parameters. See Chapter 11, Configuration Database, for full documentation of this feature.
Configuration Database view, set for 5 Active Indexes, with Capture Settings highlighted
Quadrus MINI Imager User’s Manual
10-13
Page 280
Dynamic Setup
Dynamic Setup Dynamic Setup is used to calculate image capture timing during a read cycle. Without proper timing, the imager will not be able to decode all symbols in a read cycle. An external trigger is used to activate image captures so the user can make timing adjustments as capture events occur.
Read Rate is represented graphically in real-time as the user makes adjustments to the time delay between image captures. The user can control Capture #, Number of Captures, and Number of Symbols using these spin boxes.
The Delay Adjustment slider allows the user extremely precise control of the time delays between image captures in a read cycle. Delay values are shown in seconds in the field above the slider. The Coarse and Fine Delay Adjustment options determine whether larger or smaller adjustment increments will be used.
10-14
Quadrus MINI Imager User’s Manual