Page 11

Introduction

Statement of Agency Compliance

The Quadrus MINI Imager has been tested for compliance with FCC (Federal Communications Commission) regulations and has been found to conform to all applicable FCC Rules and Regulations. To comply with FCC RF exposure compliance requirements, this device must not be co-located or operate in conjunction with any other antenna or transmitter. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

The Quadrus MINI Imager has been tested for compliance with CE (Conformité Européenne) standards and guidelines, and has been found to conform to applicable CE standards, specifically the EMC requirements EN 55024:1998+A1:2001+A2:2003, ESD EN 61000-4-2, Radiated RF Immunity EN 61000-4-3, ENV 50204, EFT EN 61000-4-4, Conducted RF Immunity EN 61000-4-6, EN 55022:1998+A1:2000+A2:2003 for Class A products, Class B Radiated Emissions, and Class B Conducted Emissions. The Quadrus MINI Imager has been tested by an independent electromagnetic compatibility laboratory in accordance with the applicable specifications and instructions.

Quadrus MINI Imager User’s Manual xi

Page 12

Statement of Agency Compliance xii

Quadrus MINI Imager User’s Manual

Page 13

1 Quick Start Contents Step 1 Check Required Hardware ................................................................................................ 1-2 Step 2 Connect the System .......................................................................................................... 1-3 Step 3 Position Imager and Symbol.............................................................................................. 1-4 Step 4 Install ESP ......................................................................................................................... 1-5 Step 5 Select Model...................................................................................................................... 1-6 Step 6 Select Protocol and Connect ............................................................................................. 1-7 Step 7 Locate the Symbol in the Field of View ............................................................................. 1-9 Step 8 Calibrate ......................................................................................................................... 1-11 Step 9 Test Read Rate .............................................................................................................. 1-12 Step 10 Configure the Imager in ESP........................................................................................ 1-13 Step 11 Save Configuration in ESP ........................................................................................... 1-14

This chapter is designed to get your Quadrus MINI Imager up and running quickly, using the EZ button or ESP (Easy Setup Program). Following these steps will allow you to get a sense of the imager’s capabilities and to test sample symbols. Detailed setup information for installing the imager into your actual application can be found in the subsequent chapters.

Quadrus MINI Imager User’s Manual

1-1

Page 14

Check Required Hardware

Step 1, Check Required Hardware Item 1 2 3 4 5 6

Description Quadrus MINI Imager IC-332 Adapter IB-131 Interface Box Power Supply (90-264 VAC, 24VDC, USA/Euro plug) Object Detector Communication Cable

Part Number FIS-6300-XXXXG FIS-0001-0035G 99-000018-01 97-100004-15 99-000017-01 61-300026-03

1 2 3

6 Host

4

Network

Scanner

5

Hardware Required

Caution: Be sure that all cables are connected BEFORE applying power to the system. Always power down BEFORE disconnecting any cables.

1-2

Quadrus MINI Imager User’s Manual

Page 15

Quick Start

Step 2, Connect the System Connecting by RS-232/RS-422/RS-485 • Connect the imager (1) to the IB-131/IC-332 interface (2) and (3). • Connect the host cable (6) to the host and to the host port on the IB-131 (3). • Connect the object detector (5) to the IB-131 (3). • Connect the power supply (4) to the IB-131 (3). • Apply power to the imager. Important: If you are using a USB model, you must connect the device to the host computer before powering-on. Otherwise the unit will not be recognized as a USB device.

1 2 3

6 Host

4

Network

Scanner

5

Hardware Configuration

Caution: Be sure that all cables are connected BEFORE applying power to the system. Always power down BEFORE disconnecting any cables.

Quadrus MINI Imager User’s Manual

1-3

Page 16

Position Imager and Symbol

Step 3, Position Imager and Symbol • Position the imager at a focal distance between 2 and 6 inches from the symbol. • Tip the imager relative to the symbol to avoid the glare of direct (specular) reflection. The case parting line should be perpendicular to the plane of the symbol by either pitching the symbol or the imager as shown. • Position the imager in a place with as little ambient light as possible. • Symbols can be rotated (tilted) at any angle; however, for best results symbols should be aligned with the FOV (field of view).

Imager and Symbol Orientation • In the case of linear symbols, aligning the bars in the direction of their movement (“ladder” orientation) will minimize the chances of blurring, and will produce better reads. Important: Avoid excessive skew or pitch. Maximum skew is ±30°; maximum pitch is ±30°. The illustration below shows skew axis, pitch axis, and tilt axis. Bar code label axis Skew

Tilt axis Tilt

Symbol Scanner

Pitch Pitch axis

Reader

Scan line

Note: For accuracy of testing and performance, Microscan recommends using a mounting arm adapter kit. Contact your Microscan sales manager for details about mounting arm adapter kits and other accessories. 1-4

Quadrus MINI Imager User’s Manual

Page 17

Quick Start

Step 4, Install ESP Easy Setup Program (ESP) is Microscan’s proprietary setup and testing application. The purpose of ESP is to provide a quick and easy way to set up and configure Microscan readers. When the Quadrus MINI is connected to a host computer (Windows Vista, XP, or 2000), ESP can be used to configure reader settings and to set up communications between the reader and host.

If installing from the Microscan Tools CD: 1. Insert the Microscan Tools CD in your computer’s CD drive. 2. Select ESP Software from the navigation bar at the left of the screen. 3. Click on ESP Software under the Current Version heading. 4. Click the Run button and follow the prompts in the ESP Setup Wizard. Note: During installation, you may see an Internet Explorer Security Warning that states: “The publisher could not be verified.” If you see this warning, click Run to continue installation.

If downloading from the web: 1. Go to the Download Center at www.microscan.com. 2. Create a new member account or, if you are already a member, enter your user name and password. 3. Navigate to the “Microscan Software” section of the Download Center (near the top of the page). 4. Click on the link showing the latest version of ESP. Extract the ESP installation files to a location of your choice on the host computer. Note where your ESP.exe file is stored on your hard drive. 5. At the end of the installation process, the following icon will appear on your desktop:

6. Click the ESP icon to start the program.

System Requirements for ESP • 166 MHz Pentium processor (recommended) • Windows Vista, XP, or 2000 operating system • Internet Explorer 5.0 or higher • 64 MB minimum RAM • 40 MB minimum disk space • 800 x 600 pixel minimum 256 color display

Quadrus MINI Imager User’s Manual

1-5

Page 18

Select Model

Step 5, Select Model When you start ESP, the following menu will appear:

1. Click the button showing the Quadrus MINI. 2. Click OK. Note: You can also double-click the Quadrus MINI button to make your selection. 3. Click Yes when this dialog appears:

Note: If you need to select another model later, click the Switch Model button near the top of the screen or use Model > New Model in the menu toolbar.

1-6

Quadrus MINI Imager User’s Manual

Page 19

Quick Start

Step 6, Select Protocol and Connect • Choose the connection protocol you are using and click Next when the Select Protocol dialog appears.

• Once you select your communications mode, follow the prompts to establish your connection.

If you choose RS-232 protocol: Click Connect.

If you choose USB protocol:

Quadrus MINI Imager User’s Manual

Select the Quadrus MINI from the Select Device menu and click Finish.

1-7

Page 20

Select Protocol and Connect (cont.)

Step 6, Select Protocol and Connect (cont.) When you are connected, you will see the green connection indicator in the status bar at the bottom right of your screen. RS-232: USB: • If your RS-232 connection attempt fails, click the Autoconnect button, select a different communications port, and try again. Note: If your RS-232 host settings cannot be changed to match the imager’s settings: • Click Connect on ESP’s menu toolbar, and then select Connection Wizard. • When the Select Protocol dialog appears, select RS-232 and click Next.

• When the RS-232 dialog appears, check the Force Connect box and click the Connect button.

1-8

Quadrus MINI Imager User’s Manual