The text of a manual · part 16 of 43
Quadrus MINI Imager User's Manual, pages 151 to 160
Pages 151 to 160 of 424
The original document is the PDF (3.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MINI 6300
Page 151
Symbologies
UPC/EAN Usage:
Definition:
Serial Cmd: Default: Options:
Used primarily in point-of-sale applications in the retail industry. It is commonly used with Microscan readers in applications in combination with Matchcode when there is a need to verify that the right product is being placed in the right packaging. UPC (Universal Product Code) is a fixed length, numeric, continuous symbology. UPC can have two- or five-digit supplemental bar code data following the normal code. The UPC Version A (UPC, A) symbol is used to encode a 12 digit number. The first digit is the number system character, the next five are the manufacturer number, the next five are the product number, and the last digit is the checksum character. When enabled, the imager will read UPC Version A and UPC Version E only. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Disabled 0 = Disabled 1 = Enabled
EAN Status Usage:
Definition:
Serial Cmd: Default: Options:
EAN is the European version of the UPC symbology and is used in European market applications. Note: UPC must be enabled for EAN to take effect. EAN is a subset of UPC. When enabled, the imager will read UPC Version A, UPC Version E, EAN 13, and EAN 8. It also appends a leading zero to UPC Version A symbol information and transmits 13 digits. If transmitting 13 digits when reading UPC Version A symbols is not desired, disable EAN. Note: The extra character identifies the country of origin. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Disabled 0 = Disabled 1 = Enabled
Quadrus MINI Imager User’s Manual
6-23
Page 152
UPC/EAN
Supplementals Status (UPC/EAN) Usage: Definition: Serial Cmd: Default: Options:
Reads Supplementals typically used in publications and documentation. A supplemental is a 2 to 5 digit symbol appended to the main symbol. When set to Enabled or Required, the imager reads supplemental code data that has been appended to the standard UPC or EAN codes. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Disabled 0 = Disabled 1 = Enabled 2 = Required
Disabled UPC Supplementals will not be decoded.
Enabled When enabled, the imager will try to decode a main and a supplemental. However, if a supplemental is not decoded, the main will be sent by itself at the end of the read cycle.
Required When set to Required, both the main and the supplemental symbols must be read or a single No Read condition results. For example, if Supplementals is set to Required, Separator is enabled, and an asterisk is defined as the UPC separator character. Then the data is displayed as: MAIN * SUPPLEMENTAL. Note: Under no circumstances will the supplemental symbol data be sent without a main symbol. Note: If additional symbols - other than the main or supplemental - will be read in the same read cycle, Number of Symbols should be set accordingly.
Separator Status (UPC/EAN) Usage: Definition: Serial Cmd: Default: Options:
6-24
Allows users to distinguish between the main and Supplemental symbols. A character can be inserted between the standard UPC or EAN symbology and the supplemental symbology when Supplementals is set to Enabled or Required. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Disabled 0 = Disabled 1 = Enabled
Quadrus MINI Imager User’s Manual
Page 153
Symbologies
Separator Character (UPC/EAN) Note: If Separator Character has been changed to any other character and you wish to redefine the separator as a comma, you will need to use ESP. Usage: Definition: Serial Cmd: Default: Options:
As required by the application. Allows the user to change the separator character from a comma to a new character. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> , (comma) Any ASCII character.
Note: Whenever Separator Character is defined as a comma ( , ) sending a <K473,s?> command will return the current settings, including the separator character comma which appears after the separator status comma. Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K473h,,,,,3C> For >: <K473h,,,,,3E> For , : <K473h,,,,,2C> See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values.
Quadrus MINI Imager User’s Manual
6-25
Page 154
UPC/EAN
Supplemental Type (UPC/EAN) Usage: Definition: Serial Cmd: Default: Options:
As required by symbology used in application. Allows the user to select 2 character or 5 character supplements, or both. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Both 0 = Both 1 = 2 characters only 2 = 5 characters only
Both Either 2 character or 5 character supplementals will be considered valid.
2 Characters Only Only two character supplementals will be considered valid.
5 Characters Only Only five character supplementals will be considered valid.
Format UPC-E as UPC-A (UPC/EAN) Definition:
Serial Cmd: Default: Options:
6-26
When disabled, the imager will output the version E symbols in their encoded 6-character format. When enabled, the imager will format the symbol as either a 12-character UPC-A symbol or an EAN-13 symbol, depending on the state of the EAN status parameter. This formatting reverses the zero suppression that is used to generate the symbol in the UPC specification. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Disabled 0 = Disabled 1 = Enabled
Quadrus MINI Imager User’s Manual
Page 155
Symbologies
Pharmacode Usage: Definition:
Serial Cmd: Default: Options:
Used mostly with packaging for the pharmaceuticals industry. Encodes up to five different numbers, each with its own color, which may be entered in decimal or “binary” format with a 1 represented by a thick bar and a 0 represented by a thin bar. Bar width is independent of height. In decimal format, each part can be up to 999,999. In binary format, each input can have up to 19 ones and zeros. Important: When Pharmacode is enabled, other linear symbologies will not decode properly. Disable Pharmacode before reading other linear symbologies. <K477,status,fixed symbol length status,fixed symbol length,minimum number of bars,bar width status,direction,fixed threshold value> Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (Pharmacode) Definition: Serial Cmd: Default: Options:
When enabled, the imager will check the symbol length against the symbol length field. If disabled, any length will be considered valid. <K477,status,fixed symbol length status,fixed symbol length,minimum number of bars,bar width status,direction,fixed threshold value> Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (Pharmacode) Definition: Serial Cmd: Default: Options:
Specifies the exact number of bars that must be present for the imager to recognize and decode the Pharmacode symbol. <K477,status,fixed symbol length status,fixed symbol length,minimum number of bars,bar width status,direction,fixed threshold value> 5 1 to 16
Minimum Number of Bars (Pharmacode) Definition:
Serial Cmd: Default: Options:
Sets the minimum number of bars that a Pharmacode symbol must have to be considered valid. Note: When Q-Mode is enabled, the minimum allowed bar count is 4. <K477,status,fixed symbol length status,fixed symbol length,minimum number of bars,bar width status,direction,fixed threshold value> 2 1 to 16 4 to 16 (Q-Mode)
Quadrus MINI Imager User’s Manual
6-27
Page 156
Pharmacode
Bar Width Status (Pharmacode) Definition:
Serial Cmd: Default: Options:
If set to Mixed, the imager will autodiscriminate between narrow bars and wide bars. If set to All Narrow, all bars will be considered as narrow bars. If set to All Wide, all bars will be considered as wide bars. If set to Fixed Threshold, it will use the fixed threshold value to determine whether the bars are narrow or wide. The Bar Width Status setting will be ignored when the imager is able to tell the difference between the narrow and the wide bars. <K477,status,fixed symbol length status,fixed symbol length,minimum number of bars,bar width status,direction,fixed threshold value> Mixed 0 = Mixed 1 = All Narrow 2 = All Wide 3 = Fixed Threshold
Direction (Pharmacode) Definition: Serial Cmd: Default: Options:
Specifies the direction in which a symbol can be read. <K477,status,fixed symbol length status,fixed symbol length,minimum number of bars,bar width status,direction,fixed threshold value> Forward 0 = Forward 1 = Reverse
Fixed Threshold Value (Pharmacode) Definition:
Serial Cmd: Default: Options:
6-28
Used when Bar Width Status is set to Fixed Threshold. Defines the minimum difference in pixels that will distinguish a narrow bar from a wide bar. <K477,status,fixed symbol length status,fixed symbol length,minimum number of bars,bar width status,direction,fixed threshold value> 10 1 to 65535
Quadrus MINI Imager User’s Manual
Page 157
Symbologies
Postal Symbologies Note: Postal Symbologies are only supported when Q-Mode is enabled. Important: Postal Symbologies must have a pixels-per-element value of no more than 7 to be decoded reliably by the Quadrus MINI Imager. The imager must be configured to specific read range, field of view, and camera parameters before decoding Postal Symbologies. For optimal decode results with a Standard Density (SD) imager: • Set Focal Distance to 6” and configure gain and shutter settings for a high contrast image. • Enable Pixel Sub-Sampling at 4:1. • Position the imager 3.5” to 7” from the symbol (5-10” if Pixel Sub-Sampling is disabled). • Position the symbol as close to the center of the imager’s field of view as possible. Note: Measurements based on a 16 mil (60 dpi) POSTNET symbol.
Position the postal symbol in the center of the imager’s field of view.
Quadrus MINI Imager User’s Manual
6-29
Page 158
Postal Symbologies
Postal Symbology Type Usage: Definition:
The following 1D Postal Symbologies are used in mail sortation, auditing, certified mail, registered mail, metered mail, and point-of-sale (POS) applications. Determines the postal symbology that will be decoded by the imager. Postal symbology decode performance depends on accurate sampling density information. Sampling density is determined by measuring the width in pixels of a symbol image and then dividing that value by the width of the actual symbol in inches or meters. For example, an image of a one-inch-wide symbol that is 200 pixels across would have a sampling density of 200 dots per inch. The following table shows the range of supported sampling densities. Symbology U.S. Post (POSTNET, PLANET, USPS4CB) Australia Post Japan Post Royal Mail, KIX UPU
Serial Cmd: Default: Options:
6-30
Minimum Sample Density 80
Maximum Sample Density 310
Unit of Measurement
3150
12205 dots per meter
86 3386 84 3307 82 3228 80 3150
332 13071 324 12756 317 12489 310 12205 dots per inch dots per meter dots per inch dots per meter dots per inch dots per meter dots per inch dots per meter dots per inch
<K460,postal symbology type,POSTNET status,PLANET status,USPS4CB status,POSTNET allow B and B’ fields,Australia Post allow 0 FCC> Disabled 0 = Disabled 1 = U.S. Post (POSTNET, PLANET, USPS4CB) 2 = Australia Post 3 = Japan Post 4 = Royal Mail 5 = KIX 6 = UPU
Quadrus MINI Imager User’s Manual
Page 159
Symbologies
U.S. Post (POSTNET, PLANET, USPS4CB) When U.S. Post is enabled (<K460,1>), the imager will only decode POSTNET, PLANET, and USPS4CB symbols. Important: POSTNET Status, PLANET Status, and USPS4CB Status are enabled by default. However, if any of the three U.S. Post symbologies is set to disabled individually, symbols of that type will not be decoded by the imager even when U.S. Post is enabled. For example, if U.S. Post is enabled but POSTNET Status is disabled (<K460,1,0>), POSTNET symbols will not be decoded by the imager. See POSTNET Status, PLANET Status, and USPS4CB Status for more detail about U.S. Post symbologies.
Australia Post When Australia Post is enabled (<K460,2>), the imager will only decode Australia Post symbols.
Japan Post When Japan Post is enabled (<K460,3>), the imager will only decode Japan Post symbols.
Royal Mail When Royal Mail is enabled (<K460,4>), the imager will only decode Royal Mail symbols.
KIX When KIX is enabled (<K460,5>), the imager will only decode KIX symbols.
UPU When UPU is enabled, the imager will decode UPU symbols and any U.S. Post symbologies that might be enabled. For example, if Postal Symbology Type is set to UPU and POSTNET Status is enabled and (<K460,6,1>), the imager will attempt to decode both UPU and POSTNET symbols.
Quadrus MINI Imager User’s Manual
6-31
Page 160
Postal Symbologies
POSTNET Status Usage:
Definition: Serial Cmd: Default: Options:
POSTNET is used by the United States Postal Service to direct mail. The ZIP Code or ZIP+4 Code is encoded in the symbol. Data is encoded in half-height and full-height bars, making POSTNET a “2-state” symbology. The delivery point (usually the last two digits of the address or post office box number) is also typically encoded in POSTNET symbols. If U.S. Post and POSTNET Status are both enabled, the imager will decode POSTNET symbols. <K460,postal symbology type,POSTNET status,PLANET status, USPS4CB status,POSTNET allow B and B’ fields,Australia Post allow 0 FCC> Enabled 0 = Disabled 1 = Enabled
PLANET Status Usage:
Definition: Serial Cmd: Default: Options:
6-32
PLANET (Postal Alphanumeric Encoding Technique) is a symbology used by the United States Postal Service to track and identify items during delivery. Each PLANET symbol is either 12 or 14 digits long, and encodes data in half-height and full-height bars, making PLANET a “2-state” symbology. The symbol always starts and ends with a full-height bar, or “guard rail”, and each individual digit is represented by a set of five bars in which two of the bars are always short. If U.S. Post and PLANET Status are both enabled, the imager will decode PLANET symbols. <K460,postal symbology type,POSTNET status,PLANET status, USPS4CB status,POSTNET allow B and B’ fields,Australia Post allow 0 FCC> Enabled 0 = Disabled 1 = Enabled
Quadrus MINI Imager User’s Manual