Page 9
Chapter 1 Wedge Quick Start
Step 2, Connect the System To connect the IB-3 PC system, do the following: 1. Power-off your host computer. 2. Set the IB-3 PC (1) switch to position 1. 3. Connect the MS-3 (2) and the keyboard (3) to the IB-3 PC (1) as shown. 4. Plug the IB-3 PC cable directly into the host computer’s (4) keyboard port. Caution: Be sure all cables are connected BEFORE applying power. and always power down BEFORE disconnecting any cables
KEYBRD OUT/ POWER IN 98-000049-01 1 SERIAL COMM. 2 CONFIG. 3 KEYBOARD WEDGE
3 2 1
Position 1
KEYBOARD IN
1–Wedge Quick
1
SCANNER
IB-3PC HOST/SERIAL
5. Power-on host computer. 6. Open a word processor or text editor to see scanned or typed data.
KEYBRD OUT/ POWER IN 98-000049-01 SCANNER
IB-3PC 1 SERIAL COMM. 2 CONFIG. 3 KEYBOARD WEDGE
HOST/SERIAL
2
3 2 1 KEYBOARD IN
3 4
Figure 1-2 Hand Presentation Setup for Keyboard Wedge
IB-3 PC Keyboard Wedge User’s Manual
1-3
Page 10
Step 3, Configure Your MS-3 For the MS-3 Laser Scanner: Scan the following bar code symbols in the order that they are presented. 1. Enable configuration mode.
2. Enable Continuous Read 1.
1–Wedge Quick
3. Set 5 second timeout.
4. Enable all symbologies (no beep on this one).
5. Save for power-on.
You will now be able to scan in data from your bar codes through the wedge from your laser scanner.
1-4
IB-3 PC Keyboard Wedge User’s Manual
Page 11
Chapter 1 Wedge Quick Start
For the MS-3 CCD Reader The two bar code symbols below will setup the MS-3 CCD for reading with the IB-3 PC.
Enable all Symbologies
1–Wedge Quick
Set Read Mode
Note: There is no beeper on the MS-3 CCD but whenever a good read occurs the reader’s LED will momentarily turn OFF and then ON and the Good Read lamp will flash ON and OFF.
IB-3 PC Keyboard Wedge User’s Manual
1-5
Page 12
Step 4, Test The following bar code symbol can be used to test the your setup:
1234
1–Wedge Quick
Important: You must have your IB-3 PC set to Position 1 and have a text editor open in order to see the results.
1-6
IB-3 PC Keyboard Wedge User’s Manual
Page 13
2–Wedge Configura-
In addition to its primary wedge operations, the IB-3 PC wedge can be programmed from the host by <W...> commands. In this mode, you can select the IB-3 PC’s keyboard emulation (AT or XT), map keyboard characters to ASCII characters, set capitalization option, setup flow control, and save and default the wedge.
KEYBRD OUT/ POWER IN 98-000049-01 SCANNER
IB-3PC 2 CONFIG.
HOST/SERIAL 3
2
3 KEYBOARD WEDGE
2
Wedge Configuration
1 SERIAL COMM.
Chapter
2 1 KEYBOARD IN
IB-3 PC Keyboard Wedge User’s Manual
2-1
Page 14
Required Hardware
Required Hardware • (1) An IB-3 PC, FIS-0001-0030G. • (2) A Microscan reader. • (3) A customer supplied keyboard with a PS/2 plug. • (4) A DB-9 serial communications cable, P/N 61-000010-01 • (5) Host computer.
2–Wedge Configura-
1 KEYBRD OUT/ POWER IN 98-000049-01 SCANNER
IB-3PC 3 SERIAL COMM. 2 CONFIG. 1 KEYBOARD WEDGE
HOST/SERIAL
4
3
2
2 1 KEYBOARD IN
3
5
Figure 2-3 Configuration Setup
2-2
IB-3 PC Keyboard Wedge User’s Manual
Page 15
Chapter 2 Wedge Configuration
Connect the System
KEYBRD OUT/ POWER IN 98-000049-01
1. Power off your host computer. 2. Set the IB-3 PC switch to position 2. 3. Connect the IB-3 PC (1) to the MS-3 (2) at the 15-pin “SCANNER” connector. 4. Connect the keyboard (3) to the IB-3 PC with the PS/2 2 plug. 5. Connect the IB-3 PC’s cable (1) (extending from the “KEYBRD OUT/ POWER IN” end) into the host’s keyboard port.1 6. Connect the DB-9 serial communications cable (4) to the host’s RS-232 serial port (figure 2-4) or to an alternative configuration computer as shown in figure 2-5. Caution: Be sure all cables are connected BEFORE applying power. and always power down BEFORE disconnecting any cables SCANNER
IB-3PC
1 SERIAL COMM.
2 CONFIG.
3 KEYBOARD WEDGE
HOST/SERIAL 3 2 1
KEYBOARD IN
2–Wedge Configura-
7. Apply power to the system.
1 KEYBRD OUT/ POWER IN 98-000049-01 SCANNER
IB-3PC 3 SERIAL COMM. 1 KEYBOARD WEDGE
4
2 CONFIG.
HOST/SERIAL
1
3
2
2
KEYBRD OUT/ POWER IN
1
98-000049-01
IB-3PC SCANNER
KEYBOARD IN
3 SERIAL COMM. 2 CONFIG.
3
1 KEYBOARD WEDGE
4
3
2
2 1 KEYBOARD IN
3
Figure 2-4 Configuration Setup
Figure 2-5 Alternative Configuration Setup
1. If using your own null modem RS232 host cable, be certain that the host’s TxD connects to the scanner’s RxD and the scanner’s TxD connects to the host’s RxD. IB-3 PC Keyboard Wedge User’s Manual
2-3
Page 16
IB-3 PC Configuration
IB-3 PC Configuration
2–Wedge Configura-
Command Format Commands to the IB-3 PC Keyboard Wedge follow the same numeric format as those applied to our bar code scanners except that the IB-3 PC uses a <W...> as a prefix instead of a <K...>. Example: <W700,alphanumeric data,more alphanumeric data> Important: If you want to scan in bar code configuration commands to the IB-3 PC, you must switch over to Position 1. However, keyboard entry configuration to the IB-3 PC must be done while in Position 2. (See “Serial Operations” on page 3-1.) Important: Before you can enter serial keyboard commands from position 2 to the IB-3 PC, you must enable muting with the <W500,1> command. Failure to do this will result in an endless loop following any keystroke. There are two ways to enable muting: 1. In switch Position 2, send the macro <W500,1>. Note: You must send this command as a macro since keying it in will result in an endless loop that looks like this: <<<<<<<<<<<.... 2. In switch Position 1, scan in the Enable Muting symbol: Once you have enabled muting, you can configure the IB-3 PC in position 2 by typing in commands or sending macros.
Terminal Connection You can use Microscan’s ESP (Easy Setup Program) to see configuration commands that are echoed to your monitor. To connect with the MS-3 terminal, do the following: 1. Select on Settings in the Connect pulldown menu list. 2. In the RS-232 tab, select 9600 baud, Even parity, One stop bit, Seven data bits. 3. Check Force Connect and click Connect. 4. Connect to the MS-3. 5. Click the Terminal button.
2-4
IB-3 PC Keyboard Wedge User’s Manual