Spec sheet · Microscan
Microscan IB-131 Specs
Spec sheet2 pagesPDF 616 KB
Both pages are below, each with its text.
Names · 1 model
The models it names
Filed with · 2 models
Also filed with these models on the old site
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
Microscan two-page specification sheet for the IB-131 interface module, which gives the MS-911 and MS-810 scanners separate ports for host, power, trigger and network. It lists the cables and part numbers, connector types and pinouts, size, supply voltage, and diagrams for stand-alone, multidrop and daisy chain setups.
- Device
- Interface module with separate host, power, trigger and network ports for MS-911 and MS-810 scanners p. 1
- Power
- Regulated +10–28 VDC p. 1
- Host connector
- 25-pin D-subminiature socket p. 1
- Other connectors
- Scanner: 15-pin D-sub socket; network: 25-pin D-sub plug; trigger: 4-pin MicroChange socket; power: 3-pin MicroChange plug p. 1
- Part numbers
- IB-131: 99-400005-02 (one per MS-911); IB-131 Kit: 98-400002-02 (one per MS-810) p. 2
- Dimensions
- 3.2 in. L x 3.15 in. W x 0.75 in. H (8.13 x 8 x 1.9 cm) p. 1
- RS-232 cable
- 61-300026 (for PC) p. 2
- Multidrop cable
- 61-100030, connects multiple IB-131s p. 2
- Daisy chain cable
- 61-100029, connects multiple IB-131s p. 2
- Power supply
- 97-10004-05, one for each scanner p. 2
- Trigger
- 99-440001-10, one for each scanner p. 2
- Network port
- For multidrop or daisy chain setups; also gives access to the programmable outputs p. 1
What this sheet walks you through
- Stand-alone setup with the scanner talking directly to the host p. 2
- Multidrop setup linking several scanners to one host p. 2
- Daisy chain setup making several MS-911 scanners act as one p. 2
- Connector pinouts for host, scanner, network, trigger and power p. 1
Good to know
- The pinout tables show active pins only. p. 1
- The daisy chain configuration lists multiple MS-911 scanners only. p. 2
Questions this sheet answers
What is the Microscan IB-131?
An interface module that gives MS-911 and MS-810 scanners separate host, power, trigger and network ports. p. 1
What power supply does the IB-131 need?
A regulated +10–28 VDC supply; the listed power supply part number is 97-10004-05. p. 1, 2
Which IB-131 part number is for the MS-810?
The IB-131 Kit, 98-400002-02, one per MS-810; the plain IB-131 is 99-400005-02, one per MS-911. p. 2
What cable connects IB-131 modules in multidrop?
Multidrop cable 61-100030; for daisy chain it is 61-100029. p. 2
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
Network Device
The IB-131 interface module simplifies connecting to the MS-911 and MS-810 scanners by providing seperate ports for the host, power supply, trigger and network. The network port is used for multidrop or daisy chain configurations. This port can also be used to access the programmable outputs. See reverse side for configuration diagrams. The following is a list of cables offered by Microscan for ease of connectivity when using the IB-131. MS-810 MS-911
- RS-232 Cable: 61-300026
- Multidrop Cable: 61-100030
- MS-810 Kit: 98-400002-02
- RS-232 Cable: 61-300026
- Multidrop Cable: 61-100030
- Daisy Chain Cable: 61-100029
IB–131 SPECIFICATIONS MECHANICAL
CONNECTORS*
Length: 3.2 in. (8.13 cm) Width: 3.15 in. (8 cm) Height: 0.75 in. (1.9 cm)
Host Connector: 25-pin D-subminiature Socket
PinFunction1External ground2Transmit data (RS-232)3Receive data (RS-232)4RTS5 6CTS Output 2+7Signal ground8Output 1+9Trigger –PinFunction1 2
+10–28 VDC Transmit RS-232/RS-422–
3Receive RS-232/RS-422–4Signal Ground5Trigger–6
RTS/Aux. Transmit RS-232/RS-422+
7 8
Output 1+ Default configuration
9
Trigger+
10 CTS/Aux. Receive RS-232/RS-422+ 11 Output 3+
10 Trigger+ 11 Default configuration 13 Receive data (RS-422+) 14 Transmit data (RS-422–) 15 Output 3+ 16 Receive data (RS-422–) 17 Output 1–/2–/3– 19 Transmit data (RS-422+) 25 New master/OMR
Trigger Connector: 4-pin MicroChange Socket
Pin
Scanner Connector: 15-pin D-subminiature Socket
Function
12 New master/OMR 13 External ground 14 Output 2+ 15 Output 1–/2–/3–
Network Connector: 25-pin D-subminiature Plug
PinFunction1Ground2Aux. Receive RS-2323Aux. Transmit RS-2326
Out 2 + Signal ground Out 1 +
1+10–28 VDC7 82Trigger –
13 Receive data (RS-422+)
3
Ground
14 Transmit data (RS-422–)
4
Trigger+
15 Out 3 + 16 Receive data (RS-422–)
Power Connector: 3-pin MicroChange Plug
Pin 1 3Ground +10–28 VDCFunction
17 Output 1–/2–/3– 19 Transmit data (RS-422+)
ELECTRICAL Supply Voltage Input: Regulated +10–28 VDC
Microscan Systems, Inc. Tel 425 226 5700 / 800 251 7711 Fax 425 226 8250
Microscan Europe Tel 31 172 423360 / Fax 31 172 423366
Microscan Asia Pacific R.O. Tel 65 846 1214 / Fax 65 846 4641
www.microscan.com E-mail: info@microscan.com
*Pinout tables show active pins only.
© 2000 Microscan Systems, Inc. Specifications subject to change. 08/00 ISO 9001/Cert. No. 00-1047
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
IB–131 CONFIGURATIONS STAND-ALONE This configuration allows the scanners to operate independently, communicating directly with the host. Typical configuration:
- MS-911 or MS-810 Scanner
- IB-131: 99-400005-02 (1 per MS-911)
- IB-131 Kit: 98-400002-02 (1 per MS-810)
- RS-232 Serial Cable: 61-300026 (for PC)
U
U
- Power Supply: 97-10004-05 (for each scanner)
- Trigger: 99-440001-10 (for each scanner)
MULTIDROP This setup allows the user to link multiple scanners together, using only one host. Typical configuration:
- Multiple or Combination of MS-911 and MS-810
- IB-131: 99-400005-02 (1 per MS-911) U
- IB-131 Kit: 98-400002-02 (1 per MS-810)
- Multidrop Cable: 61-100030 (connects multiple IB-131s)
- Power Supply: 97-10004-05 (for each scanner)
- Trigger: 99-440001-10 (for each scanner)
DAISY CHAIN This setup allows the user to link the primary and successive scanners to function as one scanner. Typical configuration:
- Multiple MS-911 scanners
- IB-131: 99-400005-02 (1 per MS-911)
- Daisy Chain Cable: 61-100029 (connects multiple IB-131s)
- Power Supply: 97-10004-05 (for each scanner)
- Trigger: 99-440001-10 (for each scanner)
© 2000 Microscan Systems, Inc. Specifications subject to change. 08/00 ISO 9001/Cert. No. 00-1047
U
U