Page 21
Application Mode
Application Mode App Mode allows you to access configuration menus, Utilities tools, and a Terminal where serial commands can be entered. Click this icon to Connect to the scanner.
Menu toolbar.
Click here to open the Terminal or Utilities views.
Click the Parameters icon to return to full App Mode view from Terminal or Utilities. Click on these tabs to access configuration trees like the one shown below.
2-2
HS-1 Handheld Scanner User’s Manual
Page 22
Using ESP
Menu Toolbar File > New Whenever New is selected, the default configuration of ESP is loaded.
Open/Save When Save or Save As is selected, the ESP configuration is saved to the host computer’s hard drive and available whenever the same file is selected under Open. Important: When you save menu changes to your hard drive, these changes are not saved to the HS-1. The illustration below shows how settings can be saved and received between ESP and the HS-1, and ESP and the host hard drive.
(Save to Scanner) (Receive Reader Settings)
Import/Export Import converts the ASCII settings from a text file to ESP configuration settings. Export converts the active ESP configuration settings to an ASCII text file.
HS-1 Handheld Scanner User’s Manual
2-3
Page 23
Menu Toolbar
Model In the Model menu you can select any of the models supported by ESP. When you choose a different model, the connection to your present model will be terminated.
To connect to another model, select New Model, choose a new model from the pop-up menu that appears, and click OK. Note: When you save an ESP file, you are saving the settings of all the models defined in that file.
2-4
HS-1 Handheld Scanner User’s Manual
Page 24
Using ESP
Options The Options menu allows you to save memos and set up ESP Preferences. Note: Preferences will be saved and loaded into ESP whenever ESP is opened next, whether or not you save the ESP file.
Preferences > General Tab
The Toolbar Style options allow you to determine how ESP will display the mode options in the two rows at the top of the screen.
Reload Last File At startup, reloads the last file saved to the host computer’s hard drive.
Show Model Prompt At startup, shows the model menu displaying all supported readers.
Show Connect Prompt At startup, displays the Would you like to connect to the HS-1? prompt.
Receive After Connect At startup, loads the HS-1’s settings into ESP. (This is not recommended if you want to preserve your ESP settings for future use.)
HS-1 Handheld Scanner User’s Manual
2-5
Page 25
Menu Toolbar
Preferences > Terminal Tab
Show Non-Printable Characters When Show Non-Printable Characters is enabled, characters such as “CRLF” will be displayed in the Terminal window. When Enhanced Format is checked, the characters are displayed with more detailed formatting.
Change Keyboard Macros Clicking the Change Keyboard Macros button brings up the Function Keys dialog. In this dialog you can select the desired function key and then enter your macro keystrokes in the associated key map. For example, to make Ctrl-F2 the keystroke to send a trigger character, select F2, then in the Ctrl row, enter <trigger character> and click OK. Then whenever the Ctrl-F2 keystroke is pressed, the trigger character will start the read cycle. Note: The F1 key is reserved for opening ESP Help and the F3 key is reserved for the Find Next function.
Change Font Allows you to modify the font used for decode data received from the HS-1 on the Terminal screen.
Change Echo Font Allows you to modify the font used for command characters typed into the Terminal view.
Enable Echo Allows you to enter command characters in Terminal.
Display Incoming Data Even When Not in Focus When Display Incoming Data Even When Not in Focus is enabled, data from the HS-1 will continue to appear in the Terminal even when ESP is not the top window. 2-6
HS-1 Handheld Scanner User’s Manual
Page 26
Using ESP
Preferences > Bar Code Options Tab
The Bar Code Options dialog allows you to set the size of user-created symbols.
Sizing Information Sets the bar width or module width (in mils, or thousandths of an inch) of user-created symbols. Example: A bar width of 14 is 0.014 inches.
Caption Allows you to define and position a human-readable caption for the symbol you create.
HS-1 Handheld Scanner User’s Manual
2-7
Page 27
Menu Toolbar
Preferences > Advanced Tab
Send XON with Autoconnect Sends an XON (Begin Transmission) command to the HS-1 before starting the Autoconnect routine.
Ask to Save ESP File when Quitting When enabled, prompts the user to save a .esp file when ending a session.
The .esp file will be saved in the location of your choice.
2-8
HS-1 Handheld Scanner User’s Manual
Page 28
Using ESP
Preferences > Advanced Tab (cont.) Connect to Reader via TCP/IP When enabled, shows an Ethernet option on the Select Protocol dialog. Note: This option should only be selected if you intend to connect using an Ethernet adapter.
Use Default Storage Location When enabled, automatically stores data in ESP’s Application Data folder.
HS-1 Handheld Scanner User’s Manual
2-9
Page 29
Menu Toolbar
Document Memo The information you type in the Document Memo field will appear in a context-sensitive text box whenever your cursor hovers over the Document Memo item on the Options menu.
Model Memo Similar to Document Memo, the information you type in the Model Memo field will appear in a context-sensitive text box whenever your cursor hovers over the Model Memo item on the Options menu. Memos created in Model Memo are specific to the model enabled when the message was created.
Note: Memos must be saved in a .esp file if you want them to available in your next session. If you do not save your current session, any memos that you have entered during the session will be discarded, and will be unavailable in your next session.
2-10
HS-1 Handheld Scanner User’s Manual
Page 30
Using ESP
Autoconnect • If your RS-232 connection attempt fails, you can use Autoconnect to establish a connection between the HS-1 and the host.
• If your communications port is not the default COM1, use the dropdown menu to change your port.
• Once you have chosen the correct port, click Start to connect.
When you are connected, you will see the green connection indicator in the status bar at the bottom right of your screen:
HS-1 Handheld Scanner User’s Manual
2-11