Page 71
Front Panel HawkEye™ 1510
Front Panel HawkEye™ 1510 Figure 2–43 shows the layout of the front panel for the HawkEye™ 1510.
2 Connecting to the HawkEye™ 1500
FIGURE 2–43. Front Panel Layout (HawkEye™ 1510 only)
Light Port Connector CS Lens Mount
•
Light Port Connector – 12 VDC out
•
CS Lens Mount – 5mm extension required to support C-Mount lenses (5 mm extension tube part number is 928-0047-1)
Light Port Connector Figure 2–44 shows the pinout for the light port connector. FIGURE 2–44. Light Port Connector
1
2
Table 2–24 lists the supplier for the light port mating connector. TABLE 2–24. Light Port Mating Connector Supplier v2.4.1, Nov 2008
Supplier
Part Number
Description
Molex
51090-0200 50212-8100
2 Position housing Crimp terminal
HawkEye™ 1500 Series User Manual
2-45
Page 72
Chapter
2
Connecting to the HawkEye™ 1500
FIGURE 2–45. Optional Light Port Cable
RED BLACK
REV
A1-40118-1
3.250 RED 1 2
BLACK
Table 2–25 lists the pinout for the light port. TABLE 2–25. Light Port Pinout
Pin 1 2
Signal Name +12VDC
State
Voltage
Off
Open
On/Strobe
+12V
Power Strobe
+24V
12V return
Table 2–26 lists the part number for the optional light port cable. TABLE 2–26. Optional Light Port Cable Part Number
Microscan P/N
Description
A1-40118-1
Cable, light port DC power to external light head
Do not exceed 0.5 amp continuous current draw or you may damage the HawkEye™ 1500.
2-46
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 73
Mounting Blocks
Mounting Blocks Table 2–27 contains the part numbers and descriptions of the four mounting blocks for the HawkEye™ 1500 camera. TABLE 2–27. Mounting Blocks
Part Number
Description
Used on HawkEye™
Notes
HEBMA-5
Standard mounting block
1510, 1515, 1525
HEBMA-2
Optional mounting block
1525
1
HEBMA-3
HE10 mounting block adapter
1510
2
HEBMA-4
HE15 mounting block adapter
1515
3
Notes: 1.
This mounting block is required for the HawkEye™ 1525 when mounting the reader where the mounting surface extends to the light. This mounting block is 3/8” thick vs. ¼” thick for the standard block.
2.
Allows a HawkEye™ 1510 to mount in the same location when upgrading an HawkEye™ 10.
3.
Allows a HawkEye™ 1515 to mount in the same location when upgrading an HawkEye™ 15.
Note: Do not insulate the mounting block. The bottom of the HawkEye™ gets hot and metal-to-metal contact is necessary for heat dissipation. Refer to Appendix E, “Specifications,” for mounting block dimensions.
Optional Location for Mounting Block Figure 2–46 shows the optional locations for the mounting block on the HawkEye™ 1500.
v2.4.1, Nov 2008
HawkEye™ 1500 Series User Manual
2-47
Connecting to the HawkEye™ 1500
2
Page 74
Chapter
2
Connecting to the HawkEye™ 1500
FIGURE 2–46. Optional Location for Mounting Block (1515 Shown)
kEy Haw e
HOLE LOCATION FOR OPTIONAL MOUNTING BLOCK LOCATION
0.64mm (.025)
19.05mm (.750) 41.91mm (1.650)
50.80MM (2.000)
Remove the two hole covers before installing mounting block in one of the two optional mounting locations, as shown in Figure 2–46. (A HawkEye™ 1515 is shown.) Use 4-40 x 5/16 pan head screws.
Using longer screws may damage the HawkEye™ 1500.
2-48
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 75
3 HawkEye™ 1500 Series Overview
3
The chapter contains an overview of the HawkEye™ 1500 Series Smart CameraBased Reader. It also contains information about application modes, lighting modes, retry modes, and I/O operations. For verification information, see the HawkEye™ 1500 Series Verification Manual. The HawkEye™ 1500 has a wide variety of applications ranging from reading symbols on parts speeding by on a conveyer to stationary applications where each symbol is manually presented. The HawkEye™ 1500 has a rich set of options for dealing with different triggering, lighting, and I/O situations. ReadRunner, the HawkEye™ 1500 Graphical User Interface, provides a simple way of setting up all the various parameters. In particular, it presents a small number of application modes, each of which pre-sets the various parameters based on common usage scenarios. These application modes are merely starting points; any parameter can be subsequently altered, if necessary. For more information, see “Application Modes” on page 3-3. Control over exposure of acquired images is referred to as photometry. The HawkEye™ 1500 provides both manual and automatic photometry. The autophotometry mode is quite powerful and can adjust the exposure and gain separately for each image acquisition. For more information, see “QuicSet® Symbol Photometry” on page 3-35 and “Setting Up Photometry” on page 4-22. For situations where the symbol may be moving or difficult to decode, several different retry modes are provided. The HawkEye™ 1500 can retry by count, v2.4.1, Nov 2008
HawkEye™ 1500 Series User Manual
3-1
HawkEye™ 1500 Series Overview
CHAPTER 3
Page 76
Chapter
3
HawkEye™ 1500 Series Overview time, or for the duration of an input signal. For more information, see “Retry Modes” on page 3-6. There are several options available for configuring digital I/O. To interface to external equipment, you have the option of either using a timed data valid signal or a full handshake. For more information, see “HawkEye™ 1500 I/O Operations” on page 3-10. The HawkEye™ 1500 also provides a rich set of ways to send data to external equipment, either using serial or network connections. The capabilities are very powerful but are also very simple to use. The options range from sending the decode data as a simple ASCII string via the serial port, up to sending a “Cycle Report” for each decode. The Cycle Report includes counts, timing data, and much more, and may even contain images. Libraries are included that allow custom data collection applications to be easily written using Visual Basic. For more information, see “Displaying Camera Report Information” on page 4-15. The normal operational mode of the HawkEye™ 1500 is called “online”. In this mode, the results of each decode are sent to all connected client applications. Without taking the camera out of this mode, it is possible to program the camera and change parameters “on the fly.” This is called taking control of the unit. When a client takes control, it essentially has a private connection to the camera and results are not sent to other clients. For more information, see Chapter 4, “ReadRunner”. Note: Use this device as specified by Microscan.
3-2
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 77
Unique Camera Names
Unique Camera Names At boot time, if a camera’s network name is “HawkEye,” the camera’s software automatically changes “HawkEye” to “HawkEyexxyyzz” where xxyyzz is the last three fields of the camera’s MAC address. For example: TABLE 3–1. Unique Camera Names
MAC Address
Unique Camera Name
HawkEye
00:60:33:e0:00:11
HawkEyeE00011
HawkEye
00:60:33:e0:00:12
HawkEyeE00012
HawkEye
00:60:33:e0:00:13
HawkEyeE00013
HawkEye
00:60:33:e0:00:14
HawkEyeE00014
HawkEye
00:60:33:e0:00:15
HawkEyeE00015
3 HawkEye™ 1500 Series Overview
Camera Name at Boot Time
Application Modes To integrate the HawkEye™ 1500 with various scanning applications, one may need to change its operating parameters. As an aid to configuring the HawkEye™ 1500, ReadRunner has an Application Mode display available to you. This display contains four choices that generalize typical use for the HawkEye™ 1500. From the selection chosen, a number of pre-defined parameter selections are made. You may override any of these selections at any time. The four general application modes are: •
Demo
•
Stop and Scan
•
Motion
•
Supermarket
Demo Demo mode is the default application mode. It is fully automatic in operation. Illumination, targeting, automatic photometry, and continuous triggering are all on. The HawkEye™ 1500 will continuously read any symbol that is aligned to the laser target dots, that is, placed in the field of view.
v2.4.1, Nov 2008
HawkEye™ 1500 Series User Manual
3-3
Page 78
Chapter
3
HawkEye™ 1500 Series Overview
Motion This mode scans a symbol when it moves within the HawkEye™ 1500’s field of view. Because the parts are in motion, there is no time for the automatic calculation of photometry values. Thus, automatic photometry is off. You must specify the exposure and gain settings manually. A trigger is supplied (through the I/O connector) to the camera by a sensor device. In addition, the Lighting selection will be Power-strobe. This selection allows the parts to be moving at a very high speed, where short exposure times are desired.
Stop and Scan This mode scans a symbol when it stops within the HawkEye™ 1500’s field of view. A trigger is supplied (through the I/O connector) to the camera by a sensor device when the symbol is in place. The illumination and laser targeting are set to strobe, and the automatic photometry control is on. When the trigger is supplied, the HawkEye™ 1500 will determine the correct gain and exposure and read the symbol.
Supermarket This is often referred to as Presentation Mode. Parameters similar to those for Demo mode are used with the exception that an inter-symbol wait time (ISWT) is imposed. This means that, when a symbol is presented to the HawkEye™ 1500’s field of view, it will be read once. The same symbol cannot be read again until the symbol is removed from the field of view for at least the indicated ISWT. A different symbol, when presented to the camera, will be read immediately.
Lighting Modes Symbols or marks that are to be read by the HawkEye™ 1500 must be illuminated for optimum read performance. Depending on the type of surface texture or ambient light surrounding the symbol, the lighting may be customized. In addition, there are several models of the HawkEye™ 1500 available (Chapter 1, “Configurations”), and it is assumed that you have purchased the model that is optimal for the application that you are deploying. All models have the following configurations available to control the light installed on your particular unit:
3-4
•
On/Off
•
Strobe
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 79
Lighting Modes
•
Power Strobe
•
On With Power Strobe
•
External (may be used with any of the other modes)
As detailed earlier in this chapter, when you select one of the four Application Modes, ReadRunner selects the appropriate lighting mode. You may override these selections as desired. The details of each are as follows:
3
WARNING! STROBING MAY HAVE ADVERSE EFFECTS ON HUMANS WHO ARE PRE-DISPOSED TO SEIZURES DUE TO PHOTOSENSITIVITY. PLACING THE HAWKEYE™ 1500 IN AN ENCLOSURE CAN MINIMIZE THE EFFECTS OF THE FLASHING OF A STROBE.
v2.4.1, Nov 2008
•
Off, This selection is available when the ambient lighting provided is adequate for the optimal reading of the parts to be deployed. Therefore, the internal lighting will not be used during the exposure time.
•
On, This selection turns the built in lighting on continuously. The lighting will be on at all times, and at a constant intensity. It will be the lighting used during the exposure time.
•
Strobe, Strobed lighting is chosen to illuminate the symbol for just the selected exposure time. Typically, this is chosen when the symbol/part to be read is in motion and at relatively slow speeds. At all other times, the HawkEye™ 1500 turns off the lighting. This results in a flashing effect.
•
Power Strobe, This selection is similar to the strobed selection, with the addition of a greater intensity value being supplied. This is employed when the part is in motion and at very high speeds. The burst of energy supplied for the duration of the exposure time allows parts to be in motion at much greater speeds. The maximum limit on exposure time is 1 ms.
•
On With Power Strobe, This selection is provided to keep the lighting on at all times, but, when the camera is exposing, the Power Strobe intensity is supplied.
HawkEye™ 1500 Series User Manual
3-5
HawkEye™ 1500 Series Overview
Note: Strobing minimizes the heat produced when the light is on constantly.
Page 80
Chapter
3
HawkEye™ 1500 Series Overview
Note: This selection minimizes the effects of strobing on human vision. •
External, When external lighting is selected, the HawkEye™ 1500 will NOT illuminate its internal lighting, but will drive an external line to control an external source for the desired exposure time. This external line can be wired to an external lighting configuration that is optimal for the unique problem set. For more information about wiring, etc., see Chapter 2, “Connecting to the HawkEye™ 1500”. External lighting is allowed in conjunction with the other lighting modes to allow more flexibility in developing lighting solutions.
In addition, four other modes are available by combining the preceding modes: •
On & External
•
Strobe & External
•
PowerStrobe & External
•
On/PowerStrobe/External
Note: When Verification is set to “AIM DPM-1-2006”, Lighting will be set to On.
Retry Modes When you select the typical application via ReadRunner, there is no attempt at setting any retry capabilities. This is user dependent. The various Retry Modes are described here so you can apply them as needed.
3-6
•
Time
•
Count
•
GPIO IN 4 Duration
•
ISWT
•
PID List
•
PID List w/Acquire
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008