The text of a manual · part 5 of 34
HawkEye 1500 Series User Manual, pages 41 to 50
Pages 41 to 50 of 338
The original document is the PDF (3.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan HE1510, RVSI CiMatrix HE1510 and Siemens HE1510
Page 41
I/O Expansion Module (Optional)
Jumper (JMP1) must be set to positions 2&3 to use General Purpose I/O 1. Notes: Setting JMP1 to positions 2&3 will disable the “Strobe” output. In this position, the camera must not be set to External Strobe mode; refer to the camera’s user manual to set the camera illumination mode to something other than External Strobe mode. +24 volts DC power (fused @ 100mA) is brought out directly from the 15-pin HD-Sub header (J1) to barrier strip (TB1) position 1. Internal +5 volts DC is generated from the 24 volt DC source and provides logic power to the 4 General Purpose I/O Optos IO1 through IO4. The Smart Camera I/O board accepts only 5-volt-logic solid-state relays (Opto 22™ G4-type isolator modules). Note: There is no connector for connecting external isolator module power (5 volts). •
Strobe, The external strobe output is a TTL signal from the camera that connects to the barrier strip (TB1) position 12 (STROBE) via the 15-pin HD-Sub header (J1) and jumper (JMP1). The strobe output signal has an inline Lo-Pass filter with a 2Mhz cutoff. There is a Strobe LED (STRB) that indicates whenever the strobe signal is ON (high). Jumper (JMP1) must be set to positions 1&2 to use the strobe output. Note: Setting JMP1 to positions 1&2 will disable General Purpose I/O 1. To use External Strobe, the camera must be set to External Strobe illumination mode; refer to either of the following:
v2.4.1, Nov 2008
HawkEye™ 1500 Series User Manual
2-15
2 Connecting to the HawkEye™ 1500 these modules is terminated on the barrier strip TB2. General Purpose I/O ports (isolator modules) 1 through 4 may be configured as either inputs or outputs. The TTL I/O signals from the camera enter via the 15-pin HD-Sub header (J1) on positions 5, 7, 8, & 9 corresponding to General Purpose I/O points 1 through 4. The TTL I/O signals are filtered with EMI “T” filters. There are four LED's that indicate whenever the TTL I/O signals are ON (low). The LED's operate whether or not an isolator module is plugged in.
Page 42
Chapter
2
Connecting to the HawkEye™ 1500
Chapter 4 of this manual. The ILLUMINATION command in the HawkEye™ 1500 Series Reference & Programmers Manual. •
Spare Fuse & 5VOK LED, There is a spare fuse in the spare fuse socket which doubles as a fuse/+5 volt OK test circuit. When the green LED (5VOK) is ON it indicates that both +5 volts and the fuse are OK. Note: There is no connector for connecting external 5 volts.
Table 2–10 lists the part numbers for the Smart Camera I/O board and interface cables. TABLE 2–10. I/O Expansion Module Suppliers
Part Number
Description
003-406000
I/O Expansion Module - includes:
966-0183-1
Cable HD-Sub 15 connector M/M 10 Feet
Optional Cables 966-0183-2
Cable HD-Sub 15 connector M/M 15 Feet
966-0183-3
Cable HD-Sub 15 connector M/M 25 Feet
I/O Expansion Module Connectors I/O Interface Connector – J1 Figure 2–11 shows the pinout for the HDB-15S connector. FIGURE 2–11. Field I/O (HDB-15S) Connector
2-16
11 6
15 10
1
5
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 43
I/O Expansion Module (Optional)
TABLE 2–11. Pinout I/O Interface Connector, J1
Description
1
Sensor Input A
2
Opto Output 1 A
3
Opto Output 2 A
4
Opto Output 3 A
5
General Purpose I/O 1 or Strobe
6
+24 volts
7
General Purpose I/O 2
8
General Purpose I/O 3
9
General Purpose I/O 4
10
24 volt return (Ground)
11
Sensor Input B
12
Opto Output 1 B
13
Opto Output 2 B
14
Opto Output 3 B
15
I/O Return (Ground)
Shell
Chassis Ground
Connecting to the HawkEye™ 1500
Pin
2
Opto In, Opto Out, & Strobe Output Terminal Block – TB1 Figure 2–12 shows the I/O expansion module TB1.
v2.4.1, Nov 2008
HawkEye™ 1500 Series User Manual
2-17
Page 44
Chapter
2
Connecting to the HawkEye™ 1500
FIGURE 2–12. I/O Expansion Module, TB1
TB1 +24 volts Sensor Input A Opto Output 1 A Opto Output 2 A Opto Output 3 A Strobe Output Ground
2 4 6 8 10 12 14
1
Chassis Ground
3
Ground
5
Sensor Input B
7
Opto Output 1 B
9
Opto Output 2 B
11
Opto Output 3 B
13
Ground
TABLE 2–12. Pinout Opto In, Opto Out & Strobe Terminal Block, TB1
2-18
Pin
Description
1
Chassis Ground
2
+24 volts
3
24 volt return (Ground)
4
Sensor Input A (Trigger)
5
Sensor Input B (Trigger)
6
Opto Output 1 A
7
Opto Output 1 B
8
Opto Output 2 A
9
Opto Output 2 B
10
Opto Output 3 A
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 45
I/O Expansion Module (Optional)
TABLE 2–12. Pinout Opto In, Opto Out & Strobe Terminal Block, TB1
(Continued) Opto Output 3 B
12
Strobe
13
Strobe Return (Ground)
14
Ground
2 Connecting to the HawkEye™ 1500
11
General Purpose I/O Terminal Block – TB2 Figure 2–13 shows the I/O expansion module TB2. FIGURE 2–13. I/O Expansion Module, TB2
Opto 1 Opto 2 Opto 3 Opto 4 v2.4.1, Nov 2008
1 + 2
-
3 + 4
-
5 + 6
-
7 + 8
-
HawkEye™ 1500 Series User Manual
2-19
Page 46
Chapter
2
Connecting to the HawkEye™ 1500
TABLE 2–13. Pinout General Purpose I/O Terminal Block, TB2
Pin
Description
1
G.P. Opto 1 Positive (+) Terminal
2
G.P. Opto 1 Negative (-) Terminal
3
G.P. Opto 2 Positive (+) Terminal
4
G.P. Opto 2 Negative (-) Terminal
5
G.P. Opto 3 Positive (+) Terminal
6
G.P. Opto 3 Negative (-) Terminal
7
G.P. Opto 4 Positive (+) Terminal
8
G.P. Opto 4 Negative (-) Terminal
Field I/O Wiring Examples Input Opto Wiring Sample wiring diagrams for trigger input A and B (opto input) are located on terminal block TB1 positions 4 and 5 (see Figure 2–14 and Figure 2–15). FIGURE 2–14. Input Opto Wiring (Isolated NPN and PNP Sources) NPN Source +5-24V
PNP Source
Camera Vcc
Camera
+5-24V Signal
Vcc
Signal
2-20
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 47
I/O Expansion Module (Optional)
FIGURE 2–15. Input Opto Wiring (Non-Isolated NPN and PNP Sources) NPN Source
PNP Source
Camera +24 VDC
Vcc
2
Camera +24 VDC
Vcc
Connecting to the HawkEye™ 1500
Signal
Signal
Output Opto Wiring Sample wiring diagrams for PASS, FAIL, and DATA VALID outputs (opto outputs 1, 2, and 3) are located on terminal block TB1 (see Figure 2–16 and Figure 2–17): •
PASS (opto output 1), Positions 6 and 7
•
FAIL (opto output 2), Positions 8 and 9
•
DATA VALID (opto output 3), Positions 10 and 11
The assignment of PASS, FAIL, AND DATA VALID to these lines is the default factory setting. In V2.0, other outputs can be configured to come out on the OPTO_OUT1, OPTO_OUT2, and OPTO_OUT3 lines.
v2.4.1, Nov 2008
HawkEye™ 1500 Series User Manual
2-21
Page 48
Chapter
2
Connecting to the HawkEye™ 1500
FIGURE 2–16. Output Opto Wiring (Isolated Input)
<50V
<50V
Input OR Input
FIGURE 2–17. Output Opto Wiring (Isolated Relay and PLC Inputs)
Camera
Relay
Camera
<50V
PLC <50V PLC Input GND
Figure 2–18 shows the output opto wiring for non-isolated inputs.
2-22
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 49
I/O Expansion Module (Optional)
FIGURE 2–18. Output Opto Wiring (Non-Isolated Inputs)
+24 VDC
Camera
2
Host
+24 VDC Input Input
The maximum current that can pass through the optoisolators is 50 mA.
Non-isolation setup can cause damage to the HawkEye™ 1500 if excessive voltage is applied to the optoisolators.
Sample wiring diagrams for strobe output (TTL I/O 1 in strobe mode) are located on terminal block TB1 positions 12 and 13 (GND) (see Figure 2–19 and Figure 2–20):
v2.4.1, Nov 2008
HawkEye™ 1500 Series User Manual
2-23
Connecting to the HawkEye™ 1500
Host
Camera
Page 50
Chapter
2
Connecting to the HawkEye™ 1500
FIGURE 2–19. Equivalent Circuit of TTL IO 1 in Strobe Mode +5V 20 ma current limit
Voh=4V @ ioh=20 ma 10 strobe
2.2K tvs + filter
FIGURE 2–20. External DIO (TTL IO 1 Only) Wiring in Strobe Mode
Camera
User Strobe Interface
+5V 20 mA current limit
To Strobe input (20 mA max @ 4V) 2 mA
2.2K
Note: Jumper (JMP1) must be set to positions 1 and 2 to use the strobe output.
General Purpose I/O Wiring Each Opto 22™ module has two associated screw terminals. Wire them according to the manufacturer’s recommendations and your company’s electrical standards. Typically, one side of all input modules connect to the hot power terminal with input devices (e.g., switches) wired between the other contact and
2-24
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008