Page 321
Complete Source Code
' disable buttons if port is not available Dim i As Long For i = 1 To 4 btnConnect(i).Enabled = CheckSerialPort("COM" & i & ":") Next i Disconnect End Sub Private Sub Form_Unload(Cancel As Integer) Disconnect Set m_coord = Nothing End Sub Private Function CheckSerialPort(port As String) As Boolean ' this function uses MiAsciiConnection to check if ' the COM port can be opened at all - will throw exception ' on conect if in use by another application On Error GoTo err: Dim serial As New MiASCIIConnection serial.Connect port If serial.Connected Then End If serial.Disconnect CheckSerialPort = True Set serial = Nothing Exit Function err: Set serial = Nothing CheckSerialPort = False End Function
Custom Programming Using a Serial
F
Private Sub Connect(targ As String) m_coord.DeviceFocusSet targ End Sub Private Sub m_connection_OnConnectionReset() Dim i As Long m_bGettingReport = False If m_connection.IsConnected Then SerialHook.Enabled = True Else SerialHook.Enabled = False End If v2.4.1, Nov 2008
HawkEye™ 1500 Series User Manual
F-5
Page 322
Appendix
F
Custom Programming Using a Serial Connection
End Sub Private Sub UpdateButtons() Dim i As Long m_bInUpdateButtons = True If m_connection.IsConnected Then For i = 1 To btnConnect.Count If m_connection.Device.Name <> btnConnect(i).Caption Then btnConnect(i).Value = vbUnchecked Else btnConnect(i).Value = vbChecked End If Next i Else For i = 1 To btnConnect.Count btnConnect(i).Value = vbUnchecked Next i End If m_bInUpdateButtons = False End Sub Private Sub Disconnect() m_coord.DeviceFocusSet "" End Sub Private Sub btnConnect_Click(Index As Integer) If m_bInUpdateButtons Then Exit Sub If m_connection.IsConnected Then Dim i As Long For i = 1 To btnConnect.Count If btnConnect(i).Caption = m_connection.Device.Name Then m_bInUpdateButtons = True btnConnect(i).Value = vbUnchecked btnConnect(i).Refresh m_bInUpdateButtons = False End If Next i Disconnect End If If btnConnect(Index).Value = vbChecked Then Connect btnConnect(Index).Caption End If UpdateButtons End Sub
F-6
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 323
Complete Source Code
Private Sub ShowView(v As Long) Select Case v Case VIEW_TERMINAL m_terminal.Visible = True m_image.Visible = False m_report.Visible = False Case VIEW_IMAGE m_terminal.Visible = False m_image.Visible = True m_report.Visible = False Case VIEW_REPORT m_terminal.Visible = False m_image.Visible = False m_report.Visible = True End Select End Sub Private Sub Form_Resize() On Error Resume Next Dim y As Long y = 0 y = y + btnConnect(1).Height Dim w As Long w = ScaleWidth / 3 m_countTotal.Move 0, y, w m_countPassed.Move w, y, w m_countFailed.Move 2 * w, y, w y = y + m_countTotal.Height m_progress.Move 0, ScaleHeight - m_progress.Height, ScaleWidth m_tabstrip.Move 0, y, ScaleWidth, ScaleHeight - y - m_progress.Height With m_tabstrip m_terminal.Move .ClientLeft, .ClientTop, .ClientWidth, .ClientHeight m_image.Move .ClientLeft, .ClientTop, .ClientWidth, .ClientHeight m_report.Move .ClientLeft, .ClientTop, .ClientWidth, .ClientHeight End With End Sub Private Sub HookDevInfo_Click() m_bHookDevInfo = Not m_bHookDevInfo HookDevInfo.Checked = m_bHookDevInfo End Sub v2.4.1, Nov 2008
HawkEye™ 1500 Series User Manual
F-7
Custom Programming Using a Serial
F
Page 324
Appendix
F
Custom Programming Using a Serial Connection
Private Sub HookImages_Click() m_bHookImages = Not m_bHookImages If m_bHookImages Then m_bHookReports = True HookReports.Checked = m_bHookReports HookImages.Checked = m_bHookImages End Sub Private Sub HookReports_Click() m_bHookReports = Not m_bHookReports If Not m_bHookReports Then m_bHookImages = False HookImages.Checked = m_bHookImages HookReports.Checked = m_bHookReports End Sub Private Sub Compression_Click(Index As Integer) m_nCompression = Index Dim i As Long For i = Compression.LBound To Compression.UBound Compression(i).Checked = IIf(m_nCompression = i, vbChecked, vbUnchecked) Next i End Sub
Private Sub m_connection_OnDataTransferAborted() m_progress.Value = 0 m_progress.Visible = False m_bGettingReport = False End Sub Private Sub m_connection_OnDataTransferPercentComplete(ByVal nPercent As Integer) m_progress.Value = nPercent End Sub Private Sub m_connection_OnDataTransferStarted() m_progress.Visible = True m_progress.Min = 0 m_progress.Max = 100 m_progress.Value = 0 End Sub Private Sub m_connection_OnNewRecord(ByVal objReport As MIOBJLib.IMiCycleReport) If m_bGettingReport Then
F-8
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 325
Complete Source Code m_image.NewRecord objReport m_report.NewRecord objReport m_bGettingReport = False m_progress.Value = 100 m_progress.Visible = False End If End Sub Private Sub m_tabstrip_Click() Select Case m_tabstrip.SelectedItem.Key Case "terminal" ShowView VIEW_TERMINAL Case "image" ShowView VIEW_IMAGE Case "report" ShowView VIEW_REPORT End Select End Sub Private Sub SerialHook_Timer() If Not m_connection.IsConnected Then Exit Sub If Not m_bGettingReport Then If m_bHookDevInfo Then ' update the device info manually Dim dev As MiDevice Set dev = m_coord.DeviceFocusGet dev.RefreshInfo m_countTotal.Caption = dev.CountCycle m_countPassed.Caption = dev.CountPassed m_countFailed.Caption = dev.CountCycle - dev.CountPassed Else m_countTotal.Caption = "???" m_countPassed.Caption = "???" m_countFailed.Caption = "???" End If
Custom Programming Using a Serial
F
If m_bHookReports Then ' create a REPORTREQ command string m_bGettingReport = True Dim cmd As String cmd = "REPORTREQ " Select Case m_nCompression v2.4.1, Nov 2008
HawkEye™ 1500 Series User Manual
F-9
Page 326
Appendix
F
Custom Programming Using a Serial Connection
Case 1 cmd = cmd & " 255" Case 2 cmd = cmd & " 1" Case 3 cmd = cmd & " 4" Case 4 cmd = cmd & " 26" Case 5 cmd = cmd & " 27" Case Else MsgBox "Invalid Compression Ratio" End Select If m_bHookImages Then cmd = cmd & " 1" Else cmd = cmd & " 0" End If ' send the REPORTREQ m_connection.CommandSend cmd End If End If End Sub
F-10
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 327
Index
Symbols
.SEC Files C-1 bootloader_Reader.sec C-2 registry_Reader.sec C-2 vxWorks_Reader.sec C-2 +V 4-98 Numerics
8-bit Binary Code D-4 A
About ReadRunner 4-98 Acquisition use camera for 4-130 Adapter external i/o terminal block 2-27 Add camera 4-5, 4-6, 4-7, 4-11 Adding camera 4-7 not in network overview 4-11 on a different subnet 4-11 Advanced Tuning Window 4-104, 4-109 AIAG D-1 AIM D-1 grade 4-16 international technical specification excerpts D-9 Air Transport Association D-1 v2.4.1, Nov 2008
Alarms network overview window 4-97 ANGLE 4-77 ANGLE_FAILURE 4-60 ANSI D-8 X3.4 D-10 Aperture 4-115 Application Mode demo 3-3, 4-47 motion 3-4, 4-47 presentation 3-4, 4-48 stop and scan 3-4, 4-48 supermarket 3-4, 4-48 window 4-46 ASCII D-8 Assisted Learn enable 4-103 ATA D-1 Audio formatted 3-31 Auto learn parameters 4-105, 4-110 max exposure 4-114 max gain 4-114 min exposure 4-114 min gain 4-114 photometry 4-22 Automatic Identification Manufacturers International D-1 Automotive Industry Action Group D-1 Axial Nonuniformity 4-17 B
Barcode parameters bc decode near center 4-113 confidence 4-113 horizontal spacing 4-110
HawkEye™ 1500 Series User Manual
Index-1
Page 328
Index max barcode height 4-111 max barcode length 4-111 max barcode width 4-112 max number of bars 4-112 min barcode height 4-111 min barcode length 4-111 min barcode width 4-111 min number of bars 4-112 min quiet zone length 4-112 min threshold 4-113 num barcodes 4-110 probe direction 4-113 vertical spacing 4-111 Baud Rate 4-66, 4-67 BC Decode Near Center 4-113
Beeper turning on and off 4-87 Behavior of wildcard match 4-40 Binary Code D-4 Bit Versus Codeword D-6 Blocks mounting 2-47 BOOL 4-61 Bootloader C-2 bootloader_Reader.sec C-2 Broken Border D-4 Budget Report 4-52 Buttons add camera 4-6, 4-7, 4-11 color 4-46 details 4-98 display rate data 4-95 timing data 4-96 font 4-46 learn 4-14, 4-102 programming user 4-92 readrunner 4-6 refresh network 4-97 release 4-6 remove button 4-21 show internal messages 4-92 take control 4-6 turbo live 4-12 unlearn 4-104 zoom in 4-95
Index-2 zoom out 4-95 Byte-Oriented Error Detection and Correction Algorithm D-6 C
Cable external i/o terminal block adapter 2-34 serial adapter 2-39 cach Command 6-12 Camera adding 4-7 when on a different subnet 4-11 disconnecting from 4-21 name 4-65 unique 3-3 releasing control of 4-21 removing 4-21 report window 4-15 resolution 4-100 selecting correct 1-1 serial port baud rate 4-66, 4-67 data bits 4-67 flow control 4-67 parity 4-66, 4-67 stop bits 4-67 software upgrading C-1 taking control 4-7 upgrading software C-5 CCD 4-100 Cell sample 4-107 unit report 4-114 Certifications D-1 Chart Window 4-94 Check Sum Checking 4-117, 4-118, 4-119 Checking check sum 4-117, 4-118, 4-119 start 4-117 stop 4-117 CHECKSUM 4-77 Clear images from camera without uploading 4-127 terminal window 4-92 CLOSE Method 4-25
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 329
Index
Color button 4-46 fail 4-46 pass 4-46 Combination I/O Board wiring examples 2-26 Command text box 4-94 Commands cach 6-12 cpu 6-11 d 6-4 dbp 6-6 der 6-10 dfb 6-10 display boot params 6-6 command help 6-13 cpu registers 6-11 ethernet registers 6-10 flash blocks 6-10 last logged error 6-13 menu 6-9 system flash size 6-12 system ram size 6-12 test menu 6-5 dm 6-9 dt 6-5 dump memory 6-4 e 6-13 et 6-6 execute test 6-6 file transfer and execute 6-12 flsh 6-12 h 6-13 i-cache control 6-12 j 6-13 jump to application 6-13 m 6-5 mbp 6-7 modify boot parameters 6-7 modify memory 6-5 r 6-13 ram 6-12 reset unit 6-13 sending remote to camera 4-94 v2.4.1, Nov 2008 text box 4-93 wmr 6-11 wpr 6-11 write mac register 6-11 write phy register 6-11 x 6-12 Common Terminal 2-25 Communications configuration window 4-64, 4-71 Confidence 4-113 Configuration File loading 4-20 saving 4-19 Configuring the Part Queue 4-120 Connections network overview window 4-97 Connector DB15S 2-8 field i/o 2-8 light port 2-45 RJ45 ethernet 2-41 serial 2-39 Contrast 4-17 report 4-114 Controller network overview window 4-97 cpu Command 6-11 Ctrl +A 4-104, 4-109 +F 4-131 +F5 4-87 +F6 4-53 +G 4-71 +H 4-94 +I 4-129 +J 4-64, 4-71 +M 4-46, 4-49 +O 4-29, 4-41 +P 4-22 +Q 4-130 +R 4-15 +S 4-89 +T 4-92 +U 4-120 +V 4-25
HawkEye™ 1500 Series User Manual
Index-3
Page 330
Index
+Z 4-90 Current Image saving 4-129 Customer Settings Installed in Manufacturing 4-99 Cycle Reports storing 4-120 Cycles network overview window 4-97 D d Command 6-4 DATA 4-77 Data bits 4-67 regions D-11 storage area D-4 valid display at top of screen 4-46 full handshake 3-19, 3-22, 4-56 pipelined 3-19, 3-20, 4-56
Data Matrix 8-bit binary code D-4 additional features D-11 compared to barcode D-2 components D-3 construction 1-3 encoding schemes D-7 error correction D-5 parameters cell sample 4-107 ecc level 4-106 image style 4-106 matrix height 4-108 matrix width 4-108 num columns 4-105 num datamatrix 4-105 num rows 4-106 orientation 4-106 pixels per cell 4-107 polarity 4-106 probe direction 4-108 probe speed 4-109 probe threshold 4-109 read timeout 4-107, 4-111 warp type 4-106 weight/height ratio 4-107 symbol structure D-11 what it is D-1
Index-4
DATAHEX 4-77 DB-15S Connector 2-8 dbp Command 6-6 Debounce 3-10 Debugging 4-120 Decode backward 4-117 fail 4-85 forward 4-117 left to right 4-117 pass 4-85 right to left 4-117 string DECODE_FAILURE 4-60 Defaults restoring 4-89, 4-90 Delay 3-10 Demo Mode 3-3, 4-47 der Command 6-10 DETAILED 4-77 Details Button 4-98 dfb Command 6-10 DILATE Method 4-25 Disconnecting from a Camera 4-21 Display boot parameters command 6-6 command help command 6-13 commands sent to camera 4-92 cpu registers command 6-11 decode string at top of screen 4-46 ethernet registers command 6-10 flash blocks command 6-10 last logged error command 6-13 menu command 6-9 new images 4-132 rate data button 4-95 remove optional cs 4-117, 4-118, 4-119 report output from camera 4-92 system flash size command 6-12 system ram size command 6-12 test menu command 6-5 timing data button 4-96 Displaying barcode parameters 4-109 commands sent to camera 4-92
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008