Page 21

Working Distance The Working Distance is the distance from the front of the light to the symbol. Typically, it is dictated by whatever clearance is required for part handling between the HawkEye™ 1500 camera and the part. These standoff distances vary from a low of 3 inches (76.2mm) to a high of 5 inches (127mm) with the HawkEye™ 1515 and the HawkEye™ 1525. If you have different standoff distance requirements, the HawkEye™ 1510 camera should be used.

Selecting A Lens Standard Lens Selection Chart Table 1–1 shows the different magnifications for the HawkEye™ 1515 and HawkEye™ 1525 with built in lenses. Each type has a specific Working Distance, Field of View, and Minimum Cell Size. To determine the correct type: 1.

Determine the Cell Size for your Data Matrix. Do this by measuring the size of your Data Matrix in the horizontal direction, and by counting the number of cells in the horizontal direction. Cell Size = Matrix Size (H) / Number of Cells (H)

2.

Determine the overall field of view required to contain the Data Matrix, Quiet Zone, and to allow for the positioning of the symbol.

3.

Look in the chart to see which types have a Minimum Cell Sizes less than your cell size. Example: Assume a Data Matrix has 23 cells in the horizontal direction, is 0.75” (19.05mm) wide, and with a quiet zone, is over 1.125” (28.58mm) wide. 0.75” (19.05mm) Cell Size =

---------------------

= 0.033” (0.84mm)

23

The only HawkEye™ Type that has a Minimum Cell Size less than 0.033” (0.84mm) and a field of view greater than 1.125” (28.58mm) is the Medium Density (MD).

v2.4.1, Nov 2008

HawkEye™ 1500 Series User Manual

1-5

1 Configurations

Selecting the Correct HawkEye™ to Read Your Data Matrix

Page 22

Chapter

1

Configurations

TABLE 1–1. Lens Selection Chart

Working Distance

Field of View at Focus

Minimum Cell Size (4 Pixels/Cell)

Medium Density (MD)

5.0” (127mm) ± 1.0” (25.4mm)

1.55”H (39.37mm) x 1.19”V (30.23mm)

DM: 0.010” (0.25mm) BC: 0.005” (0.127mm)

High Density (HD)

3.0” (76.2mm) ± 0.5” (12.7mm)

1.00”H (25.4mm) x 0.75”V (19.05mm)

DM: 0.006” (0.152mm) BC: 0.003” (0.076mm)

Long High Density (LHD)

5.0” (127mm) ± 0.5” (12.7mm)

1.00”H (25.4mm) x 0.75”V (19.05mm)

DM: 0.006” (0.152mm) BC: 0.003” (0.076mm)

Super High Density (SHD)

3.5” (88.9mm) ± 0.5” (12.7mm)

0.55”H (13.97mm) x 0.42”V (10.67mm)

DM: 0.003” (0.076mm) BC: 0.0015” (0.038mm)

Ultra High Density (UHD)

2.25” (57.15mm) ± 0.125” (3.175mm)

0.25”H (6.35mm) x 0.19”V (4.83mm)

DM: 0.0013” (0.033mm) BC: 0.0005” (0.0127mm)

Type

Custom Lens Selection In addition to the HawkEye™ 1515 and HawkEye™ 1525 cameras with built in lenses, the HawkEye™ 1510 is sold with a C or CS mount that allows the use of conventional lenses. The use of conventional lenses and extension tubes allow a much larger range of ‘fields of view’ and ‘working distances’ to be accomplished. Standard lens selection criteria should be employed to select the correct optics for your application.

Selecting Lighting Standard Light Selection The HawkEye™ 1515 and HawkEye™ 1525 come with built in lights and built in lenses.

1-6

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 23

HawkEye™ 1515 FIGURE 1–5. HawkEye™ 1515 116.51mm (4.587)

57.15mm (2.250)

111.76mm (4.400)

28.58mm (1.125)

88.90mm (3.500)

22.86mm (.900)

22.23mm (.875)

k H aw

Eye

TM

44.45mm (1.750)

The HawkEye™ 1515 has a small light ring built on the front of the unit. The ring is 1.75”H (44.45mm) x 1.25”H (31.75mm) at the center of the emission zone. The ring is aimed in 15° to converge 3” (76.2mm) from the front on the unit. When the unit is used perpendicular to the part, the light acts as a bright field, high angle ring light. A second useful configuration is to angle the unit 20° off of vertical. In this configuration, the light acts as a directional high angle spotlight. The HawkEye™ 1515 configuration is the universal reader for the broadest range of Data Matrix and Barcode reading applications. Note: The HawkEye™ 1515-XL does not have lasers.

v2.4.1, Nov 2008

HawkEye™ 1500 Series User Manual

1 Configurations

Selecting the Correct HawkEye™ to Read Your Data Matrix

1-7

Page 24

Chapter

1

Configurations

HawkEye™ 1525 FIGURE 1–6. HawkEye™ 1525 72.14mm (2.840)

116.51mm (4.587) 111.76mm (4.400)

36.07mm (1.420)

22.86mm (.900)

29.97mm (1.180)

88.90mm (3.500)

Haw e kEy

TM

59.94mm (2.360)

6.35mm (.250)

9.52mm (.375) OPTIONAL MOUNTING BLOCK

The HawkEye™ 1525 has a medium size light ring built on the front of the unit. The ring is 2.375”H (60.33mm) x 1.875”H (47.63mm) at the center of the emission zone. The ring is aimed in 25° to converge 2.25” (57.15mm) from the front on the unit. When the unit is used perpendicular to the part, the light acts as a dark field, medium to low angle ring light. Typically, the HawkEye™ 1525 is used for highly reflective parts. Note: The HawkEye™ 1525-XL does not have lasers.

HawkEye™ XL details The HawkEye™ XL is designed for applications requiring ease of integration utilizing fixed optics and integrated lighting but does not need features/benefits provided by laser targeting.

1-8

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 25

Custom Light Selection HawkEye™ 1510 FIGURE 1–7. HawkEye™ 1510 98.73mm (3.887)

57.15mm (2.250)

93.98mm (3.700)

28.58mm (1.125)

5.08mm (.200) e kEy Haw

22.23mm (.875)

TM

44.45mm (1.750)

The HawkEye™ 1510 is designed for applications requiring flexibility in the selection of lighting and optics. The unit is designed with a mounting block that allows the attachment of C and CS mount lenses. Additionally, it has brackets specially designed to mount a variety of the standard NER Lights. For complete information about the HawkEye™ 1510, see Appendix A, “HawkEye™ 1510,”. Note: The HawkEye™ 1510 does not have a laser.

v2.4.1, Nov 2008

HawkEye™ 1500 Series User Manual

1 Configurations

Selecting the Correct HawkEye™ to Read Your Data Matrix

1-9

Page 26

Chapter

1-10

1

Configurations

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 27

2 Connecting to the HawkEye™ 1500

2 Connecting to the HawkEye™ 1500

CHAPTER 2

The chapter contains information to help you connect to the HawkEye™ 1500 camera. Specific information describes connectors, adapters, cables, pinouts, and signals. Note: There are no user serviceable parts inside.

Connectivity TCP/IP Port When communicating over Ethernet, the camera uses the following predefined ports. The camera establishes connections as a Server and, therefore, listens for Host clients to initiate the connection on a particular port. Any number of clients can connect to the camera, each one with their private peer-to-peer connection.

v2.4.1, Nov 2008

HawkEye™ 1500 Series User Manual

2-1

Page 28

Chapter

2

Connecting to the HawkEye™ 1500

TABLE 2–1. HawkEye™ 1500 TCP/IP Connectivity Port Name

Protocol

Number

Note

Camera Query Port

UDP

49093

Discovers HawkEye™ 1500 cameras on the current subnet.

Camera Announce Port

UDP

49094

Broadcasts the HawkEye™ 1500 camera identity on the current subnet used by Network View in ReadRunner, provides general counters, camera name, IP, IP in control, camera status, and camera software version and capability.

COMMAND

TCP

49095

Used for all HawkEye™ 1500 ASCII Commands including accessing Buffered cycle read reports (PARTQ commands).

STANDARD

SERIAL

N/A

Programs the format of the data sent via the serial port.

STANDARD

TCP

49096

Used by ReadRunner and programming COM object library for reports with images. By default lossy up to 2 per second. Connection can be programmed to lossless, i.e., inline with the read cycle.

STANDARD

TCP

49097

Used by ReadRunner and programming COM object library for reports only. By default lossy but at maximum network rate. Connection can be programmed to lossless, i.e. inline with the read cycle.

TCP1 User Connection

TCP

49098

User format configurable TCP based connection. Uses ASCII and binary keywords (IDxx), (CDxx), etc…. Note that the connection is always lossless, i.e., inline with the read cycle.

TCP2 User Connection

TCP

49099

User format configurable TCP based connection. Uses ASCII and binary keywords (IDxx), (CDxx), etc… Note that the connection is always lossless, i.e. inline with the read cycle.

TCP3 User Connection

TCP

49100

User format configurable TCP based connection. Uses ASCII and binary keywords (IDxx), (CDxx), etc… Note that the connection is always lossless, i.e., inline with the read cycle.

TCP4 User Connection

TCP

49101

User format configurable TCP based connection. Uses ASCII and binary keywords (IDxx), (CDxx), etc…

2-2

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 29

Connectivity

Note: You can enable/disable the UDP protocol through the command line. For more information, see the UDP_BROADCAST command in the HawkEye 1500 Series Reference & Programmers Manual.

Serial Port When communicating over a serial line, you need to be aware of the limitations of this communication medium and how ReadRunner and the camera handle it. There can be only one client connected to the camera. In addition, there can be only one channel to exchange data, i.e., commands and binary data. The ReadRunner UI enables a special ACK scheme that may need to be disabled once the camera has been programmed and is connected serially to a PLC or the controlling host. You can accomplish this by sending special control characters (see Table 2–2): TABLE 2–2. Serial Port Connectivity

Control Char v2.4.1, Nov 2008

Function

Ctrl+O

Turn off report output.

Ctrl+P

Toggle the state of the prompt and echo.

Ctrl+Q

Turn off command output.

Ctrl+R

Release control of the unit and put it back online.

Ctrl+S

Take control of the unit and bring it offline (forcibly).

Ctrl+T

Dump the heartbeat string to the terminal.

Ctrl+U

Toggle the display of report strings on the terminal.

Ctrl+W

Turn on command output.

HawkEye™ 1500 Series User Manual

2-3

2 Connecting to the HawkEye™ 1500

Note: Ports COMMAND, TCP1…4 use a protocol that is either ASCII or defined by you at connection time. Therefore, these ports are fully supported on a nonWindows based Host, provided the Host supports TCP/IP and a socket level API. Ports 49096 and 49097 use a binary format that is parsed into easy to use COM events and objects on the Host and is, therefore, only applicable to Windowsbased Hosts.

Page 30

Chapter

2

Connecting to the HawkEye™ 1500

If the Serial port is programmed for 7 bits per character, certain features of the ReadRunner UI are not supported; in particular, “Hook Reports” and “Hook Images” are not available, as they transfer image and counters (binary data) and cannot be represented using a 7 bit per character ASCII format. Note: Regardless of whether the 7 or 8 bits per character are programmed, “Hook Reports” and “Hook Images” must be disconnected before quitting the ReadRunner application before connecting the camera over serial to the controlling device. Output formatting settings for the serial port are available in ReadRunner under the STANDARD Tab in the Output Settings Form.

Rear Panel Figure 2–1 details the layout of the rear panel. FIGURE 2–1. Rear Panel Layout

Power Connector Ethernet Connector Power ON LED Ethernet LINK LED Ethernet ACT LED

2-4

Field I/O Connector

I/O

DC-IN

RS-232

ETHERNET PWR

Serial Port Connector

LK ACT QuicSet

QuicSet Switch

•

Power Connector – 24VDC in

•

Field I/O Connector – DB15S – 1 Opto in, 3 Opto Out, 4 GPIO (strobe out optional on GPIO 1)

•

Serial Port Connector – 8 pin mini-DIN

•

Ethernet Connector – RJ45

•

Ethernet LINK LED – Green

•

Ethernet ACT LED – Yellow

•

Power ON LED – Green

•

QuicSet Switch – Recessed

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008