Page 131

Setting Up Your Application

FIGURE 4–13. Select Configuration File Window, Loading

4 ReadRunner

Releasing Control of a Camera To release control of a camera: 1.

Click Release.

ReadRunner releases control of the camera currently selected.

Removing a Camera When you are finished using a camera and want to disconnect and remove it, use the following procedure: 1.

De-select the button of the camera you want to remove. Note: A button is de-selected when its background is blue.

2.

Right click on the button of the camera you want to remove.

3.

Highlight Remove Button.

4.

Click Remove Button.

ReadRunner removes the camera from the main ReadRunner window.

v2.4.1, Nov 2008

HawkEye™ 1500 Series User Manual

4-21

Page 132

Chapter

4

ReadRunner

Using ReadRunner The procedures in this section explain: •

“Setting Up Photometry” on page 4-22

•

“Preprocessing Images” on page 4-24

•

“Setting Up Symbology” on page 4-25

•

“Defining the Region of Interest” on page 4-26

•

Specifying preferences, the application mode, serial and TCP/IP settings, and output format strings, beginning on page 4–44

•

“Toggling the Target Laser” on page 4-86

•

“Toggling the Beeper” on page 4-87

•

“Saving Parameters on the Camera to Flash” on page 4-89

•

“Restoring Defaults” on page 4-89

•

Displaying reports and image over a serial connection, commands to and from the camera, timing and rate information, and information about cameras on the network, beginning on page 4–90

Setting Up Photometry The HawkEye™ 1500 camera can use both automatic and manual photometry: •

Auto Photometry, Default (auto exposure). The HawkEye™ 1500 camera determines lighting control at each trigger and prior to each image scan.

•

Manual Photometry, For faster read rates, you specify the exposure and gain settings.

To display the Photometry window:

4-22

1.

Press Ctrl+P, or select Photometry from the Settings menu.

2.

Click Yes when asked if you wish to control camera X. ReadRunner displays the Photometry window, as shown in Figure 4–14 (Auto Photometry selected) or Figure 4–15 (Manual Photometry selected).

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 133

Using ReadRunner

FIGURE 4–14.

Photometry Window, Auto Photometry

FIGURE 4–15.

Photometry Window, Manual Photometry

If you select Manual Photometry, you must specify the following:

–

Exposure, Move the slider left to decrease or right to increase the exposure. Range: 30 - 20000usec v2.4.1, Nov 2008

HawkEye™ 1500 Series User Manual

4 ReadRunner

If you select Automatic Photometry, the HawkEye™ 1500 camera determines lighting control at each trigger and prior to each image scan.

4-23

Page 134

Chapter

4

ReadRunner

Note: Higher values for Exposure mean a longer image acquisition time and total cycle time. –

Gain, Move the slider left to decrease or right to increase the gain. Range: 0 - 1023dB

Note: When Verification is set to No Verification, Gain and Exposure can be adjusted by AutoPhotometry or manually. When Verification is set to AIM DPM-1-2006, Gain and Exposure will be locked to the user and can only be updated by the kernel. Image preprocessing will be disabled. When Verification is set to anything other than No Verification or AIM DPM-1-2006, a Warning message will be displayed on the dialog box indicating that changing the Exposure or Gain will uncalibrate the camera. Image preprocessing will be disabled.

Preprocessing Images The Photometry window contains the Image Preprocessing dialog area where you can select the method for processing images, and the number of iterations for the method, as shown in Figure 4–16. Note: The Iterations dialog box is displayed after you select a method.

4-24

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 135

Using ReadRunner

FIGURE 4–16. Photometry Window

The methods are: •

NONE, This is the default.

•

ERODE, This method increases the dark cell size. Use this method to increase the dark cell size of a dark on light Data Matrix.

•

DILATE, This method increases the light cell size. Use this method to increase the light cell size of a light on dark Data Matrix.

•

OPEN, This method removes minor light defects of dark cells.

•

CLOSE, This method removes minor dark defects of light cells.

Setting Up Symbology Symbology specifies what kind of symbols the HawkEye™ 1500 camera will read. If the decoder is “opened up” (that is, no learn has occurred), you can specify which symbols you want read. By de-selecting symbols, you can reduce decode time. To display the Symbology and Verification window:

v2.4.1, Nov 2008

1.

Press Ctrl+V, or select Symbology and Verification from the Settings menu.

2.

Click Yes when asked if you wish to control camera X. ReadRunner displays the Symbology and Verification window, as shown in Figure 4–17.

HawkEye™ 1500 Series User Manual

4-25

ReadRunner

4

Page 136

Chapter

4

ReadRunner

FIGURE 4–17. Symbology / Verification Window

3.

Specify the kinds of symbols the HawkEye™ 1500 camera will read: –

Enable Data Matrix, Specifies that Data Matrix symbols will be read.

–

Enable Barcodes, Specifies that Barcode symbols will be read.

Defining the Region of Interest Defining a region of interest (ROI) within the HawkEye™ 1500 camera’s Field of View improves read rates and speeds up processing. To define an ROI:

4-26

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 137

Using ReadRunner

1.

Click

2.

Click Yes when asked if you wish to control camera X.

3.

Click ReadRunner displays a search ROI, as shown in Figure 4–18.

FIGURE 4–18. ROI Window

ReadRunner

4

4.

v2.4.1, Nov 2008

Use the mouse to define a smaller search area in the camera’s field of view. Adjust the ROI from any of its four corners.

HawkEye™ 1500 Series User Manual

4-27

Page 138

Chapter

4

ReadRunner

Copying Current to PID This menu item allows you to copy the current settings (always PID0) to a different PID (1 through 15). Each PID contains the following information: TABLE 4–4. Parameters Stored in Each PID

Parameter

Notes

Photometry

Gain & Exposure only. NOTE: If Autophotometry is ON (System parameters), then these PID settings are NOT used.

PreProcessing

Morphology operator and iterations

Decoder

All decoder parameters.

ReadRunner maintains the list of PIDs that are active (that were copied from Current) for use in the Advanced Retry modes. Note: These are the only PIDs available to the RETRY commands (even though there are 15 open PID slots on the camera). FIGURE 4–19. Copy Current Settings to PID # Dialog Box

Copying PID to Current This menu item allows you to copy the PID settings (1 through 15 plus read-only 99) to the current settings (PID 0).

4-28

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 139

Using ReadRunner

FIGURE 4–20. Copy to Current Settings from PID # Dialog Box

Setting Up Text Matching The Camera Report window (Figure 4–21) displays detailed information (Cycles, Decodes, and Locates, and so on) about what the HawkEye™ 1500 camera is reading.

4 ReadRunner

FIGURE 4–21. ReadRunner Camera Report Window

Text Matching disabled

If you also want to display detailed information about the number of passed and failed text matches, you have to specify the text in the Match Mode Setup window. To set up text matching: 1.

Press Ctrl+O, or select Match Mode Settings from the Settings menu. ReadRunner displays the Match Mode Setup window, as shown in Figure 4–22.

2.

Click to enable Enable Text Matching. ReadRunner displays the Match String text box (Figure 4–22).

v2.4.1, Nov 2008

HawkEye™ 1500 Series User Manual

4-29

Page 140

Chapter

4

ReadRunner

FIGURE 4–22. Text Matching Window

3.

Enter the exact text (case sensitive) you want to match. Note: You can use the * and ? wildcards in the match string definition. The Match String should contain only printable characters.

4.

Click Apply and OK.

Graphically, in the image area, ReadRunner will display either of the following messages: •

For a successful match, Code Matched

•

For an unsuccessful match, NO MATCH Error

After text matching is enabled, your Camera Report window will look similar to the one displayed in Figure 4–23.

4-30