Page 51
CALIBRATED_STRING This command reports or sets the string or date for the light source. The string inside the quotes can be an empty string or up to 251 characters long.
Single Light Configuration Syntax CALIBRATED_STRING {? | “string to save on camera”}
Multifunction Light Configuration This command reports or sets the calibration status string or date for specified or current light source. If no light type is specified, the returned result is the overall state of all light channels on the camera.
Syntax CALIBRATED_STRING [optional light type] {? | “string to save on camera”} Where: Optional light type, Is one of the following: OFF 90 D 45Q 30T_NS 30T_EW 30Q 30S_N 30S_E 30S_S 30S_W
Rev 2.4.1, Nov 2008
(90°) (Dome Light) (45° Quad Lights) (30° Two Lights North South) (30° Two Lights East West) (30° Quad Lights) (30° Single Light North) (30° Single Light East) (30° Single Light South) (30° Single Light West)
HawkEye 1500 Reference & Programmers Manual
1-37
1 Remote Commands Reference
CALIBRATED_STRING
Page 52
Chapter
1
Remote Commands Reference
CAL_MEAN_LIGHT This command reports the calibration mean light value (R_cal) of camera calibration for current light source. This is a read-only command.
Syntax CAL_MEAN_LIGHT ?
1-38
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 53
CAPTURE This command sets the source of the images to the decoder.
Syntax CAPTURE {source} Where: source, Is one of the following:
Rev 2.4.1, Nov 2008
–
CAMERA, Captures images through the camera. This is the default.
–
DIAGNOSTIC, The FPGA generates a ramp image. Used for internal testing.
–
FILES, Images are downloaded into the unit. Used for testing and debugging.
HawkEye 1500 Reference & Programmers Manual
1 Remote Commands Reference
CAPTURE
1-39
Page 54
Chapter
1
Remote Commands Reference
CELL SAMPLE This command sets cell sampling. ReadRunner program samples and averages portions of each cell to determine whether the cell is light or dark.
Syntax CELL SAMPLE {pixels} Where: pixels, Is the number of pixels: Range: 1 - 7 pixels Default: 5 pixels
1-40
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 55
CELL SIZE This command sets cell size.
Syntax CELL SIZE {pixels} Where: pixels, Is the cell size: Range: 2 - 20 pixels Default: 6 pixels
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1 Remote Commands Reference
CELL SIZE
1-41
Page 56
Chapter
1
Remote Commands Reference
CELL_UNIT This command reports the value of the cell unit multiplier by calibration for the current light source. This is a read-only command.
Syntax CELL_UNIT ?
1-42
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 57
CELL_UNIT_REPORT This command sets the cell unit report type either in pixels or mils.
Syntax CELL_UNIT_REPORT {pixels | mils}
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1 Remote Commands Reference
CELL_UNIT_REPORT
1-43
Page 58
Chapter
1
Remote Commands Reference
COLS This command specifies the number of columns to expect in the Data Matrix symbol. The algorithm uses the value specified without having to re-compute it from image to image. Note: See also “ROWS” on page 1-154.
Syntax COLS {columns} Where: columns, Is one of the following:
1-44
– cols, Range: 8 - 144
–
AUTO, Autoselect (default)
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 59
CONSOLE This command sets the vxWorks console to the serial port for debugging. Note: If the HawkEye™ 1500 is in the vxWorks shell (CONSOLE 2) and needs to be returned to the standard command interface (CONSOLE 1), the following should be typed at the vxWorks prompt (“->”): cmd “control” cmd “console 1”
Syntax CONSOLE {n} Where: n, Is the serial port number. The range is 0 - 2:
Rev 2.4.1, Nov 2008
–
0 or 1, The standard command console
–
2, The vxWorks debugging console
HawkEye 1500 Reference & Programmers Manual
1-45
1 Remote Commands Reference
CONSOLE
Page 60
Chapter
1
Remote Commands Reference
CONTRAST This command displays the results of the LEARN CALIBRATE command (maximum and minimum contrast range). This is a read-only command.
Syntax CONTRAST ? For example: CONTRAST ? yields: CONTRAST 255 0
1-46
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov