Page 211

VERSTATUS This command selects the verification grade ranges. The verification status indicates whether a Data Matrix mark is good (2), fair (1), or poor (0), based on the overall grade and two threshold values set using the command. The grades grade1 and grade2 are threshold values for good and fair marks, respectively. The valid values for grade1 and grade2 are A, B, C, or D. The value grade1 can be higher than or equal to but not lower than the value grade2. For example, the command: VERSTATUS B D configures the reader to report verification status to be 2 for grade A or B, 1 for grade C or D, and 0 for grade F.

Syntax VERSTATUS {param1} {param2} Where: param1, Is A, B, C, D –

This parameter is the lowest grade considered Good param2, Is B, C, D –

Rev 2.4.1, Nov 2008

This parameter is the lowest grade considered Fair. Param2 can never be greater than param1. If param2 = param1, verification will only give Good and Poor results, since there is no range of grades for Fair.

HawkEye 1500 Reference & Programmers Manual

1-197

1 Remote Commands Reference

VERSTATUS

Page 212

Chapter

1

Remote Commands Reference

VIEW This command displays the stored values in the PID index.

Syntax VIEW {pid#} Where: pid#, Is one of the following:

1-198

–

0, Current working area (default)

–

1 - 15

–

99, Factory defaults

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 213

VT

1

This command causes a Virtual Trigger to occur (the application must be waiting for it).

Remote Commands Reference

VT

Syntax VT {trigger} Where: trigger, Is the trigger number: Range: 0 - 27 Note: Triggers numbered 2, 4, 5, & 6 are actual GPIO lines and are considered physical; the remaining triggers are considered virtual.

Rev 2.4.1, Nov 2008

HawkEye 1500 Reference & Programmers Manual

1-199

Page 214

Chapter

1

Remote Commands Reference

WARP This command sets the matrix warping speed. Typically, Fast produces satisfactory read rates with much higher speed, although Slow sometimes can be more robust than Fast for very poor images.

Syntax WARP {opt} Where: opt, Is either of the following:

1-200

–

Fast (default)

–

Slow

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 215

WAVELENGTH

1

This command sets the customer light source’s wavelength in nm; it is used only for reporting. The default value is 640 nm.

Remote Commands Reference

WAVELENGTH

Syntax WAVELENGTH {280-880}

Rev 2.4.1, Nov 2008

HawkEye 1500 Reference & Programmers Manual

1-201

Page 216

Chapter

1

Remote Commands Reference

WIDTH This command sets the expected Data Matrix width. Note: See also “HEIGHT” on page 1-70 and “RATIO” on page 1-142.

Syntax WIDTH {opt} Where: opt, Is either of the following: – width, Is the width: Range: 20 - 1024

–

1-202

AUTO, Autoselect (default)

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 217

XDIMENSION

1

This command specifies the maximum and minimum dimension range in 0.1 mil increments. To specify 7.5 mils, enter:

Remote Commands Reference

XDIMENSION

75

Syntax XDIMENSION {max: 11 to 990} {min: 10 to (max-1)} •

Max default is 250

•

Min default is 75

Rev 2.4.1, Nov 2008

HawkEye 1500 Reference & Programmers Manual

1-203

Page 218

Chapter

1-204

1

Remote Commands Reference

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 219

2 ReadRunner Programming

2 ReadRunner Programming Reference

CHAPTER 2

Introduction The ReadRunner development libraries allow for easy development of custom applications that interface to the HawkEye™ 1500 family of readers. A unique approach, described herein, significantly simplifies user programming – yet provides maximum flexibility. The key concept that facilitates this simplicity is an object called the MiCoordinator. The MiCoordinator object allows the various components to “talk” to each other behind the scenes – so that, in most cases, the amount of custom code that needs to be written is surprisingly small.

Libraries There are three libraries that contain components of interest: •

Rev 2.4.1, Nov 2008

MIOBJ.DLL – (Microscan HawkEye™ Reader Object Type Library) This library contains lower level objects that provide the foundation for the other libraries. The MiCoordinator object mentioned above resides here, as well as the MiCycleReport object, which wraps data (reports and images) coming from a HawkEye™ 1500 reader. This library also contains objects that manage connections to HawkEye™ 1500 devices. In most cases, you will not have to deal with these connection objects directly, as these are, in turn, wrapped in even easier to use objects.

HawkEye 1500 Reference & Programmers Manual

2-1

Page 220

Chapter

2

ReadRunner Programming Reference

•

MIOBJUI.DLL – (Microscan HawkEye™ Reader ActiveX Library) This library contains several user interface objects. The most important object in this library is MiImageView, which provides an easy way of viewing images that come from a HawkEye™ 1500.

•

RRKIT.OCX – (Microscan ReadRunner ActiveX Library) This library provides many useful user interface and connection objects. This will likely be the starting point for any custom-programming project. The library itself is written in Visual Basic, which illustrates the depth available to the programmer.

Note: To include these libraries in a VB project, first include MIOBJ.DLL as a Project Reference, and then add MIOBJUI.DLL and RRKIT.OCX as Project Components.

Important Objects •

MiCoordinator, This object provides the foundation on which most of the other objects rely. Even if you do not use this object directly, understanding what is does will provide a better understanding of the other components. –

Provides behind the scenes magic glue. In fact, all instances of the MiCoordinator object within the same process are actually the exact same object. To illustrate, imagine two forms, each declaring their “own” new MiCoordinator object. Since they are both actually the same object, one control can call a method of its “own” MiCoordinator, which results in an event to the clients of all MiCoordinators.

–

Maintains list of discovered devices (HawkEye™ 1500’s). This list is provided via the Devices property. For example, in VB, you could do the following: dim coord as new MiCoordinator Dim d as MiDevice for each d in coord.Devices ‘ do something with device next d

–

2-2

Provides concept of “Focus Device”. In many cases, an application is only concerned with a single device at a time. When this is the case, the device to work with can be specified using the DeviceFocusSet method

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov