Two-page Microscan data sheet (SP055D-EN-0217) for the NERLITE Edge-to-Edge backlight illuminators used in machine vision and auto ID. It describes what the backlights are for and gives the sizes, colors, light output, environmental, connector and electrical specifications of the four sizes.

What it is
LED backlight illuminator for machine vision and auto ID; several can be combined for a larger lit area p. 1
Sizes
47x59, 71x88, 100x100 and 50x200 (active area in mm) p. 2
Colors
Red, white, blue and infrared, each in continuous and strobe versions p. 1, 2
Power
Continuous models: 24 VDC +/– 1%; strobe models: 1 ms max pulse width, 6% max duty cycle, NERLITE NL-200 series controller required p. 2
Connector
6 in. (150 mm) cable with a 4-pin M12 male connector p. 2
Light source
High output LEDs; 50,000 hours expected life p. 2
47x59 size
Active area 1.9” x 2.3” (47 mm x 59 mm); H 2.28” x W 2.3” x D 0.6”; 3 oz. (80 g) p. 2
71x88 size
Active area 2.8” x 3.5” (71 mm x 88 mm); H 3.21” x W 3.5” x D 0.6”; 5 oz. (140 g) p. 2
100x100 size
Active area 3.9” x 3.9” (100 mm x 100 mm); H 4.36” x W 3.9” x D 0.66”; 7 oz. (200 g) p. 2
50x200 size
Active area 2.0” x 7.9” (50 mm x 200 mm); H 2.4” x W 7.9” x D 0.66”; 8 oz. (230 g) p. 2
Temperature
Operating 0° to 40° C (32° to 104° F); storage 0° to 50° C (32° to 122° F); humidity up to 95% non-condensing p. 2
Wavelengths
640 nm, 470 nm and 880 nm LEDs, and 6500 K p. 2
Eye safety
The sheet states EN 60825-1 Class 1 for red, white and infrared LEDs and Class 2 for blue LEDs p. 2

What this sheet walks you through

  • Typical uses: outlining parts, measuring dimensions and thickness, viewing drilled holes p. 1
  • Specifications and options for each backlight size p. 2
  • Electrical requirements for continuous and strobe models p. 2

Good to know

  • Strobe models need a NERLITE NL-200 series lighting controller and are limited to a 1 ms pulse and 6% duty cycle. p. 2

Questions this sheet answers

What power does the Microscan edge-to-edge backlight need?

Continuous models run on 24 VDC +/– 1%; strobe models need a NERLITE NL-200 series lighting controller. p. 2

What connector does the NERLITE edge-to-edge backlight have?

A 6 in. (150 mm) cable ending in a 4-pin M12 male connector. p. 2

What sizes does the edge-to-edge backlight come in?

Four sizes with active areas of 47 x 59 mm, 71 x 88 mm, 100 x 100 mm and 50 x 200 mm. p. 2

Can several edge-to-edge backlights be combined?

Yes, the sheet says multiple lights can be combined to light larger areas for large fields of view. p. 1

The file

Size and text

Pages2
PDF524 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Microscan Edge-to-Edge Backlight Spec Sheet

The text of page 1, from the PDF itself

NERLITE ® Backlight Edge-to-Edge Backlighting Microscan’s wide range of NERLITE products can illuminate any part or mark for successful machine vision and auto ID applications.

Available In Four Sizes

Available In Three Colors & Infrared

The Edge To Edge series of backlight illuminators provide sharp contrast to outline a part’s shape, find edges and view openings such as drilled holes. Edge To Edge technology allows combining multiple lights to address large field of view applications. High intensity and uniformity are packed into a low-profile industrial package for optimal thermal management.

Backlight: At a Glance

  • Multiple lights may be combined to create larger illuminated areas
  • Variety of colors and wavelegths for both continuous and strobed power sources
  • High level of uniformity for repeatable results
  • M12 connectors for easy connections to power supplies, drivers or advanced controllers
  • Low profile, compact shape for flexible integration

Illumination Example: Object

Resulting Image

Application Examples

  • Locate or measure outside dimensions
  • View openings (e.g., drilled holes)
  • Diminsh clear glass or plastic housings
  • Measure thickness of materials
  • Locate mounting holes
  • Measure translucency
  • Diffuse incident (front) lighting

Light bulb: Resulting image clearly shows silhouette of filament inside the bulb. For more information on this product, visit www.microscan.com.

Page 2 of Microscan Edge-to-Edge Backlight Spec Sheet

The text of page 2, from the PDF itself

NERLITE ® E dge T o E dge B acklight S pecifications and O ptions BACKLIGHT 47x59 DESCRIPTION BL, 47x59, Red Continuous BL, 47x59, Red Strobe BL, 47x59, White Continuous BL, 47x59, White Strobe BL, 47x59, Blue Continuous BL, 47x59, Blue Strobe BL, 47x59, Infrared Continuous BL, 47x59, Infrared Strobe

nm/K CONT. CURRENT STROBE CURRENT mcd/cm2 640 nm 93 mA 77 640 nm 2.67 A 1100 6500 K 201 mA 880 6500 K 3.34 A 11670 470 nm 170 mA 177 470 nm 3.0 A 2510 880 nm 140 mA 880 nm 4.0 A

mw/cm2

1.6 23

Active Area: 1.9” x 2.3” (47 mm x 59 mm) Weight: 3 oz. (80 g) Dimensions: H 2.28” (58 mm) x W 2.3” (59 mm) x D 0.6” (15.2 mm)

BACKLIGHT 71x88 DESCRIPTION BL, 71x88, Red Continuous BL, 71x88, Red Strobe BL, 71x88, White Continuous BL, 71x88, White Strobe BL, 71x88, Blue Continuous BL, 71x88, Blue Strobe BL, 71x88, Infrared Continuous BL, 71x88, Infrared Strobe

nm/K CONT. CURRENT STROBE CURRENT mcd/cm2 640 nm 170 mA 77 640 nm 5.01 A 1135 6500 K 330 mA 810 6500 K 9.0 A 11050 470 nm 310 mA 175 470 nm 9.0 A 2575 880 nm 220 mA 880 nm 7.5 A

mw/cm2

1.5 26

Active Area: 2.8” x 3.5” (71 mm x 88 mm) Weight: 5 oz. (140 g) Dimensions: H 3.21” (81.6 mm) x W 3.5” (88 mm) x D 0.6” (15.2 mm)

BACKLIGHT 100x100 DESCRIPTION BL, 100x100, Red Continuous BL, 100x100, Red Strobe BL, 100x100, White Continuous BL, 100x100, White Strobe BL, 100x100, Blue Continuous BL, 100x100, Blue Strobe BL, 100x100, Infrared Continuous BL, 100x100, Infrared Strobe

nm/K CONT. CURRENT STROBE CURRENT mcd/cm2 640 nm 155 mA 95 640 nm 4.99 A 700 6500 K 350 mA 625 6500 K 9.98 A 7100 470 nm 320 mA 125 470 nm 9.98 A 1570 880 nm 250 mA 880 nm 7.99 A

mw/cm2

1 16

Active Area: 3.9” x 3.9” (100 mm x 100 mm) Weight: 7 oz. (200 g) Dimensions: H 4.36” (110.9 mm) x W 3.9” (100 mm) x D 0.66” (16.8 mm)

BACKLIGHT 50x200 DESCRIPTION BL, 50x200, Red Continuous BL, 50x200, Red Strobe BL, 50x200, White Continuous BL, 50x200, White Strobe BL, 50x200, Blue Continuous BL, 50x200, Blue Strobe BL, 50x200, Infrared Continuous BL, 50x200, Infrared Strobe

nm/K CONT. CURRENT STROBE CURRENT mcd/cm2 640 nm 155 mA 95 640 nm 4.99 A 700 6500 K 350 mA 625 6500 K 9.98 A 7100 470 nm 320 mA 125 470 nm 9.98 A 1570 880 nm 250 mA 880 nm 7.99 A

mw/cm2

1 16

Active Area: 2.0” x 7.9” (50 mm x 200 mm) Weight: 8 oz. (230 g) Dimensions: H 2.4” (60.9 mm) x W 7.9” (200 mm) x D 0.66” (16.8 mm)

ENVIRONMENTAL

Operating Temperature: 0° to 40° C (32° to 104° F) Storage Temperature: 0° to 50° C (32° to 122° F) Humidity: up to 95% (non-condensing)

LIGHTING PARAMETERS

Active Area Defined: Area of light output from the illuminator

LIGHT SOURCE

Type: High output LEDs Light Output: Millicandelas per square centimeter (mcd/cm 2) Radiant Output: Milliwatts per square centimeter (mw/cm 2) Expected Life: 50,000 hours Eye Safety: EN 60825-1: Class 1 (Red, White, Infrared LEDs); Class 2 (Blue LEDs)

CONNECTOR

Type: 6 in. (150 mm) cable terminated with 4-pin M12 male connector

ELECTRICAL

Power (Continuous Models): 24 VDC +/– 1% Power (Strobe Models): 1 ms max. pulse width, 6% max duty cycle, use of NERLITE NL-200 Series Lighting Controller is required.

QMS CERTIFICATION

www.microscan.com/quality

©2017 Microscan Systems, Inc. SP055D-EN-0217 Read Range and other performance data is determined using high quality Grade A symbols per ISO/IEC 15415 and ISO/IEC 15416 in a 25° C environment. For application-specific Read Range results, testing should be performed with symbols used in the actual application. Microscan Applications Engineering is available to assist with evaluations. Results may vary depending on symbol quality. Warranty–For current warranty information on this product, please visit www.microscan.com/warranty.